Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant

Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online t...

Full description

Bibliographic Details
Main Authors: Taehoon Heo, Seung Hyun Cho
Format: Article
Language:English
Published: Elsevier 2016-12-01
Series:Nuclear Engineering and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1738573316300882
_version_ 1811236307134840832
author Taehoon Heo
Seung Hyun Cho
author_facet Taehoon Heo
Seung Hyun Cho
author_sort Taehoon Heo
collection DOAJ
description Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.
first_indexed 2024-04-12T12:08:05Z
format Article
id doaj.art-6f443b55471745e59c8f254cda4d8317
institution Directory Open Access Journal
issn 1738-5733
language English
last_indexed 2024-04-12T12:08:05Z
publishDate 2016-12-01
publisher Elsevier
record_format Article
series Nuclear Engineering and Technology
spelling doaj.art-6f443b55471745e59c8f254cda4d83172022-12-22T03:33:40ZengElsevierNuclear Engineering and Technology1738-57332016-12-014861404141110.1016/j.net.2016.05.007Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power PlantTaehoon Heo0Seung Hyun Cho1Center for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of KoreaCenter for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of KoreaPipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.http://www.sciencedirect.com/science/article/pii/S1738573316300882High TemperatureMagnetostrictive TransducerNuclear Power PlantSecondary Piping SystemShear Horizontal WaveWall Thinning
spellingShingle Taehoon Heo
Seung Hyun Cho
Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
Nuclear Engineering and Technology
High Temperature
Magnetostrictive Transducer
Nuclear Power Plant
Secondary Piping System
Shear Horizontal Wave
Wall Thinning
title Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
title_full Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
title_fullStr Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
title_full_unstemmed Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
title_short Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
title_sort thin plate type embedded ultrasonic transducer based on magnetostriction for the thickness monitoring of the secondary piping system of a nuclear power plant
topic High Temperature
Magnetostrictive Transducer
Nuclear Power Plant
Secondary Piping System
Shear Horizontal Wave
Wall Thinning
url http://www.sciencedirect.com/science/article/pii/S1738573316300882
work_keys_str_mv AT taehoonheo thinplatetypeembeddedultrasonictransducerbasedonmagnetostrictionforthethicknessmonitoringofthesecondarypipingsystemofanuclearpowerplant
AT seunghyuncho thinplatetypeembeddedultrasonictransducerbasedonmagnetostrictionforthethicknessmonitoringofthesecondarypipingsystemofanuclearpowerplant