Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant
Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online t...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2016-12-01
|
Series: | Nuclear Engineering and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1738573316300882 |
_version_ | 1811236307134840832 |
---|---|
author | Taehoon Heo Seung Hyun Cho |
author_facet | Taehoon Heo Seung Hyun Cho |
author_sort | Taehoon Heo |
collection | DOAJ |
description | Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer. |
first_indexed | 2024-04-12T12:08:05Z |
format | Article |
id | doaj.art-6f443b55471745e59c8f254cda4d8317 |
institution | Directory Open Access Journal |
issn | 1738-5733 |
language | English |
last_indexed | 2024-04-12T12:08:05Z |
publishDate | 2016-12-01 |
publisher | Elsevier |
record_format | Article |
series | Nuclear Engineering and Technology |
spelling | doaj.art-6f443b55471745e59c8f254cda4d83172022-12-22T03:33:40ZengElsevierNuclear Engineering and Technology1738-57332016-12-014861404141110.1016/j.net.2016.05.007Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power PlantTaehoon Heo0Seung Hyun Cho1Center for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of KoreaCenter for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of KoreaPipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.http://www.sciencedirect.com/science/article/pii/S1738573316300882High TemperatureMagnetostrictive TransducerNuclear Power PlantSecondary Piping SystemShear Horizontal WaveWall Thinning |
spellingShingle | Taehoon Heo Seung Hyun Cho Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant Nuclear Engineering and Technology High Temperature Magnetostrictive Transducer Nuclear Power Plant Secondary Piping System Shear Horizontal Wave Wall Thinning |
title | Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant |
title_full | Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant |
title_fullStr | Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant |
title_full_unstemmed | Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant |
title_short | Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant |
title_sort | thin plate type embedded ultrasonic transducer based on magnetostriction for the thickness monitoring of the secondary piping system of a nuclear power plant |
topic | High Temperature Magnetostrictive Transducer Nuclear Power Plant Secondary Piping System Shear Horizontal Wave Wall Thinning |
url | http://www.sciencedirect.com/science/article/pii/S1738573316300882 |
work_keys_str_mv | AT taehoonheo thinplatetypeembeddedultrasonictransducerbasedonmagnetostrictionforthethicknessmonitoringofthesecondarypipingsystemofanuclearpowerplant AT seunghyuncho thinplatetypeembeddedultrasonictransducerbasedonmagnetostrictionforthethicknessmonitoringofthesecondarypipingsystemofanuclearpowerplant |