Biomechanical effects of S1 sacroiliac screws versus S2 sacroiliac screws on sacroiliac screws combined with a lumbar iliac fixation in the treatment of vertical sacral fractures: a biomechanical finite element analysis

Abstract Objective To examine the impact of sacroiliac screw position and length on the biomechanical properties of triangular osteosynthesis in treating unilateral vertical sacral fractures and provide a clinical reference. Methods Unilateral Denis type II sacral fractures were modelled using finit...

Full description

Bibliographic Details
Main Authors: Yupeng Ma, Tao Huang, Weiwei Liu, Huanyu Hong, Yong Zhao, Jiangtao Lin, Yu Li
Format: Article
Language:English
Published: BMC 2023-09-01
Series:BMC Musculoskeletal Disorders
Subjects:
Online Access:https://doi.org/10.1186/s12891-023-06884-y
Description
Summary:Abstract Objective To examine the impact of sacroiliac screw position and length on the biomechanical properties of triangular osteosynthesis in treating unilateral vertical sacral fractures and provide a clinical reference. Methods Unilateral Denis type II sacral fractures were modelled using finite elements to represent Tile C pelvic ring injuries. Six sacroiliac screws were used with iliolumbar fixation patterns to fix the sacral fractures, and the sacral stability, maximum pressure, and stress distribution were compared among the internal fixation modalities. Results The best vertical stability of the internal fixation model was achieved when the S1 segment was fixed with lengthened sacroiliac screws, followed by when the S1 segment was fixed using normal sacroiliac screws. There was no significant difference in vertical stability between the S1 + S2 dual-segment fixation model and the S1-segment fixation model. The maximum pressure under a vertical force of 600 N showed a trend of L5LS1 < L5NS1 < L5LS12 < L5LS2 < L5NS2 < L5NS12. Conclusions In unilateral vertical sacral fractures (Denis II) treated with triangular osteosynthesis using triangular jointing combined with unilateral iliolumbar + sacroiliac screw fixation, the use of a single lengthened sacroiliac screw for the S1 segment is recommended to achieve the best vertical stability of the sacrum with less maximum compression on the internal fixation components. If it is not possible to apply a lengthened sacroiliac screw, the use of a normal sacroiliac screw for the S1 segment is recommended. Adding an S2 screw does not significantly increase the vertical stability of the sacrum.
ISSN:1471-2474