Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks

Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in ho...

Full description

Bibliographic Details
Main Authors: Kosay Abdul sattar Majbor, Qais Matti Alias, Wafa Faraj Tobia, Mohamed Adnan Hamed
Format: Article
Language:English
Published: University of Baghdad 2017-12-01
Series:Journal of Engineering
Online Access:https://www.jcoeng.edu.iq/index.php/main/article/view/405/351
_version_ 1797724406889316352
author Kosay Abdul sattar Majbor
Qais Matti Alias
Wafa Faraj Tobia
Mohamed Adnan Hamed
author_facet Kosay Abdul sattar Majbor
Qais Matti Alias
Wafa Faraj Tobia
Mohamed Adnan Hamed
author_sort Kosay Abdul sattar Majbor
collection DOAJ
description Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in holding the oil industry infrastructure behind regarding maintenance and modernization. The primary concern in this work is the design and implementation of cathodic protection systems for the aboveground storage tanks farm in the oil industry. Storage tank external base area and tank internal surface area are to be protected against corrosion using impressed current and sacrificial anode cathodic protection systems. Interactive versatile computer programs are developed to provide the necessary system parameters data including the anode requirements, composition, rating, configuration, etc. Microsoft-Excel datasheet and Visual Basic.Net developed software were used throughout the study in the design of both cathodic protection systems. The case study considered in this work is the eleven aboveground storage tanks farm situated in al-Shauiba refinery in southern IRAQ. The designed cathodic protection systems are to be installed and monitored realistically in the near future. Both systems were designed for a life span of (15-30) years, and all their parameters were within the internationally accepted standards.
first_indexed 2024-03-12T10:16:49Z
format Article
id doaj.art-6fd4df49af294b92a982d639f226914e
institution Directory Open Access Journal
issn 1726-4073
2520-3339
language English
last_indexed 2024-03-12T10:16:49Z
publishDate 2017-12-01
publisher University of Baghdad
record_format Article
series Journal of Engineering
spelling doaj.art-6fd4df49af294b92a982d639f226914e2023-09-02T10:26:12ZengUniversity of BaghdadJournal of Engineering1726-40732520-33392017-12-0123128295Cathodic Protection Design Algorithms for Refineries Aboveground Storage TanksKosay Abdul sattar Majbor0Qais Matti Alias1Wafa Faraj Tobia2Mohamed Adnan Hamed3Dept. of Elect. Power Tech. - Al-Mamon College Dept. of Elect. Engg. Univ. of Technology Dept. of Elect. Engg. Univ. of Technology State Comp. for Oil Projects Ministry of Oil/IRAQ Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in holding the oil industry infrastructure behind regarding maintenance and modernization. The primary concern in this work is the design and implementation of cathodic protection systems for the aboveground storage tanks farm in the oil industry. Storage tank external base area and tank internal surface area are to be protected against corrosion using impressed current and sacrificial anode cathodic protection systems. Interactive versatile computer programs are developed to provide the necessary system parameters data including the anode requirements, composition, rating, configuration, etc. Microsoft-Excel datasheet and Visual Basic.Net developed software were used throughout the study in the design of both cathodic protection systems. The case study considered in this work is the eleven aboveground storage tanks farm situated in al-Shauiba refinery in southern IRAQ. The designed cathodic protection systems are to be installed and monitored realistically in the near future. Both systems were designed for a life span of (15-30) years, and all their parameters were within the internationally accepted standards.https://www.jcoeng.edu.iq/index.php/main/article/view/405/351
spellingShingle Kosay Abdul sattar Majbor
Qais Matti Alias
Wafa Faraj Tobia
Mohamed Adnan Hamed
Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
Journal of Engineering
title Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
title_full Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
title_fullStr Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
title_full_unstemmed Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
title_short Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
title_sort cathodic protection design algorithms for refineries aboveground storage tanks
url https://www.jcoeng.edu.iq/index.php/main/article/view/405/351
work_keys_str_mv AT kosayabdulsattarmajbor cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks
AT qaismattialias cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks
AT wafafarajtobia cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks
AT mohamedadnanhamed cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks