Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks
Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in ho...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Baghdad
2017-12-01
|
Series: | Journal of Engineering |
Online Access: | https://www.jcoeng.edu.iq/index.php/main/article/view/405/351 |
_version_ | 1797724406889316352 |
---|---|
author | Kosay Abdul sattar Majbor Qais Matti Alias Wafa Faraj Tobia Mohamed Adnan Hamed |
author_facet | Kosay Abdul sattar Majbor Qais Matti Alias Wafa Faraj Tobia Mohamed Adnan Hamed |
author_sort | Kosay Abdul sattar Majbor |
collection | DOAJ |
description | Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in holding the oil industry infrastructure behind regarding maintenance and modernization. The primary concern in this work is the design and implementation of cathodic protection systems for the aboveground storage tanks farm in the oil industry.
Storage tank external base area and tank internal surface area are to be protected against corrosion using impressed current and sacrificial anode cathodic protection systems. Interactive versatile computer programs are developed to provide the necessary system parameters data including the anode requirements, composition, rating, configuration, etc. Microsoft-Excel datasheet and Visual Basic.Net developed software were used throughout the study in the design of both cathodic protection systems.
The case study considered in this work is the eleven aboveground storage tanks farm situated in al-Shauiba refinery in southern IRAQ. The designed cathodic protection systems are to be installed and monitored realistically in the near future. Both systems were designed for a life span of (15-30) years, and all their parameters were within the internationally accepted standards. |
first_indexed | 2024-03-12T10:16:49Z |
format | Article |
id | doaj.art-6fd4df49af294b92a982d639f226914e |
institution | Directory Open Access Journal |
issn | 1726-4073 2520-3339 |
language | English |
last_indexed | 2024-03-12T10:16:49Z |
publishDate | 2017-12-01 |
publisher | University of Baghdad |
record_format | Article |
series | Journal of Engineering |
spelling | doaj.art-6fd4df49af294b92a982d639f226914e2023-09-02T10:26:12ZengUniversity of BaghdadJournal of Engineering1726-40732520-33392017-12-0123128295Cathodic Protection Design Algorithms for Refineries Aboveground Storage TanksKosay Abdul sattar Majbor0Qais Matti Alias1Wafa Faraj Tobia2Mohamed Adnan Hamed3Dept. of Elect. Power Tech. - Al-Mamon College Dept. of Elect. Engg. Univ. of Technology Dept. of Elect. Engg. Univ. of Technology State Comp. for Oil Projects Ministry of Oil/IRAQ Storage tanks condition and integrity is maintained by joint application of coating and cathodic protection. Iraq southern region rich in oil and petroleum product refineries need and use plenty of aboveground storage tanks. Iraq went through conflicts over the past thirty five years resulting in holding the oil industry infrastructure behind regarding maintenance and modernization. The primary concern in this work is the design and implementation of cathodic protection systems for the aboveground storage tanks farm in the oil industry. Storage tank external base area and tank internal surface area are to be protected against corrosion using impressed current and sacrificial anode cathodic protection systems. Interactive versatile computer programs are developed to provide the necessary system parameters data including the anode requirements, composition, rating, configuration, etc. Microsoft-Excel datasheet and Visual Basic.Net developed software were used throughout the study in the design of both cathodic protection systems. The case study considered in this work is the eleven aboveground storage tanks farm situated in al-Shauiba refinery in southern IRAQ. The designed cathodic protection systems are to be installed and monitored realistically in the near future. Both systems were designed for a life span of (15-30) years, and all their parameters were within the internationally accepted standards.https://www.jcoeng.edu.iq/index.php/main/article/view/405/351 |
spellingShingle | Kosay Abdul sattar Majbor Qais Matti Alias Wafa Faraj Tobia Mohamed Adnan Hamed Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks Journal of Engineering |
title | Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks |
title_full | Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks |
title_fullStr | Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks |
title_full_unstemmed | Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks |
title_short | Cathodic Protection Design Algorithms for Refineries Aboveground Storage Tanks |
title_sort | cathodic protection design algorithms for refineries aboveground storage tanks |
url | https://www.jcoeng.edu.iq/index.php/main/article/view/405/351 |
work_keys_str_mv | AT kosayabdulsattarmajbor cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks AT qaismattialias cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks AT wafafarajtobia cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks AT mohamedadnanhamed cathodicprotectiondesignalgorithmsforrefineriesabovegroundstoragetanks |