Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building

Proper positioning of the positive pressure ventilator is an important aspect of conducting rescue operations. The purpose of this article was to determine the effect of the parameter of the distance of setting up a mobile fan (distance from 1 to 7 m) on the efficiency of implemented ventilation in...

Full description

Bibliographic Details
Main Authors: Piotr Kaczmarzyk, Łukasz Warguła, Piotr Krawiec, Paweł Janik, Rafał Noske, Wojciech Klapsa
Format: Article
Language:English
Published: MDPI AG 2023-04-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/13/9/5536
_version_ 1797602973650518016
author Piotr Kaczmarzyk
Łukasz Warguła
Piotr Krawiec
Paweł Janik
Rafał Noske
Wojciech Klapsa
author_facet Piotr Kaczmarzyk
Łukasz Warguła
Piotr Krawiec
Paweł Janik
Rafał Noske
Wojciech Klapsa
author_sort Piotr Kaczmarzyk
collection DOAJ
description Proper positioning of the positive pressure ventilator is an important aspect of conducting rescue operations. The purpose of this article was to determine the effect of the parameter of the distance of setting up a mobile fan (distance from 1 to 7 m) on the efficiency of implemented ventilation in a multistory building. The volumetric airflow rate was determined by measuring the flow velocity at 120 measurement points on the surface of the window opening (which served as the measurement plane) of a four-story building. Two positive pressure ventilators were tested (one was a conventional fan and the second a turbo type). The obtained volumetric airflow values ranged from 8591 to 15,656 m<sup>3</sup>/h, depending on the type of unit and positioning distance, respectively. The analysis performed in the article showed that the general guidelines for the distance of mobile fan positioning that are present in the literature may be inaccurate and outdated.
first_indexed 2024-03-11T04:24:16Z
format Article
id doaj.art-6fed5009e3ba4963aab239c123fc5a61
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-11T04:24:16Z
publishDate 2023-04-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-6fed5009e3ba4963aab239c123fc5a612023-11-17T22:35:20ZengMDPI AGApplied Sciences2076-34172023-04-01139553610.3390/app13095536Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory BuildingPiotr Kaczmarzyk0Łukasz Warguła1Piotr Krawiec2Paweł Janik3Rafał Noske4Wojciech Klapsa5Institute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, PolandInstitute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, PolandInstitute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, PolandScientific and Research Centre for Fire Protection, National Research Institute, 05-420 Józefów, PolandScientific and Research Centre for Fire Protection, National Research Institute, 05-420 Józefów, PolandScientific and Research Centre for Fire Protection, National Research Institute, 05-420 Józefów, PolandProper positioning of the positive pressure ventilator is an important aspect of conducting rescue operations. The purpose of this article was to determine the effect of the parameter of the distance of setting up a mobile fan (distance from 1 to 7 m) on the efficiency of implemented ventilation in a multistory building. The volumetric airflow rate was determined by measuring the flow velocity at 120 measurement points on the surface of the window opening (which served as the measurement plane) of a four-story building. Two positive pressure ventilators were tested (one was a conventional fan and the second a turbo type). The obtained volumetric airflow values ranged from 8591 to 15,656 m<sup>3</sup>/h, depending on the type of unit and positioning distance, respectively. The analysis performed in the article showed that the general guidelines for the distance of mobile fan positioning that are present in the literature may be inaccurate and outdated.https://www.mdpi.com/2076-3417/13/9/5536positive pressure ventilation (PPV)mobile fan (positive pressure ventilator)full-scale experimentfire protection unitsfanfire equipment
spellingShingle Piotr Kaczmarzyk
Łukasz Warguła
Piotr Krawiec
Paweł Janik
Rafał Noske
Wojciech Klapsa
Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
Applied Sciences
positive pressure ventilation (PPV)
mobile fan (positive pressure ventilator)
full-scale experiment
fire protection units
fan
fire equipment
title Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
title_full Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
title_fullStr Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
title_full_unstemmed Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
title_short Influence of the Positive Pressure Ventilator Setting Distance in Front of the Doorway on the Effectiveness of Tactical Mechanical Ventilation in a Multistory Building
title_sort influence of the positive pressure ventilator setting distance in front of the doorway on the effectiveness of tactical mechanical ventilation in a multistory building
topic positive pressure ventilation (PPV)
mobile fan (positive pressure ventilator)
full-scale experiment
fire protection units
fan
fire equipment
url https://www.mdpi.com/2076-3417/13/9/5536
work_keys_str_mv AT piotrkaczmarzyk influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding
AT łukaszwarguła influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding
AT piotrkrawiec influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding
AT pawełjanik influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding
AT rafałnoske influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding
AT wojciechklapsa influenceofthepositivepressureventilatorsettingdistanceinfrontofthedoorwayontheeffectivenessoftacticalmechanicalventilationinamultistorybuilding