Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test

Although buildings are often heated and cooled by single-well circulation coupled groundwater heat pump systems, few studies have evaluated the long-term performance of these systems. Therefore, the present study investigated the performance of these systems by analyzing the efficiency and energy co...

Full description

Bibliographic Details
Main Authors: Ke Zhu, Yifan Zeng, Qiang Wu, Shengheng Xu, Kun Tu, Xiaoxiu Liu
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-11-01
Series:Frontiers in Earth Science
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/feart.2021.772977/full
_version_ 1818997566392500224
author Ke Zhu
Ke Zhu
Yifan Zeng
Yifan Zeng
Qiang Wu
Qiang Wu
Shengheng Xu
Shengheng Xu
Kun Tu
Kun Tu
Xiaoxiu Liu
Xiaoxiu Liu
author_facet Ke Zhu
Ke Zhu
Yifan Zeng
Yifan Zeng
Qiang Wu
Qiang Wu
Shengheng Xu
Shengheng Xu
Kun Tu
Kun Tu
Xiaoxiu Liu
Xiaoxiu Liu
author_sort Ke Zhu
collection DOAJ
description Although buildings are often heated and cooled by single-well circulation coupled groundwater heat pump systems, few studies have evaluated the long-term performance of these systems. Therefore, the present study investigated the performance of these systems by analyzing the efficiency and energy consumption using 4 years of operating data. The results indicate that the coefficient of performance (COP) of the system gradually decreases because of thermal breakthrough or an accumulation of cold. In addition, the sealing clapboards could effectively slow down thermal breakthrough. In addition, compared with the heating period, the COP of the heat pump unit (HPU) and system increases, and its energy consumption decreases in the cooling period. It was also found that partial heat loss occurs when water from the single-well circulation outlet penetrates the main pipeline. Moreover, the heat-exchange efficiency of a single HPU exceeds that of multiple HPUs, and the COP of a HPU decreases during operation with increasing indoor temperature. Accordingly, we improved the performance of system by increasing the underground heat storage. Herein, we focus on optimizing the system design during long-term operation, which includes taking steps such as lengthening the sealing clapboards, using insulated pipes, discharging the remaining water and adding intelligent control devices.
first_indexed 2024-12-20T21:47:40Z
format Article
id doaj.art-7079ca6fe28c402093e224d7a4ba7686
institution Directory Open Access Journal
issn 2296-6463
language English
last_indexed 2024-12-20T21:47:40Z
publishDate 2021-11-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Earth Science
spelling doaj.art-7079ca6fe28c402093e224d7a4ba76862022-12-21T19:25:37ZengFrontiers Media S.A.Frontiers in Earth Science2296-64632021-11-01910.3389/feart.2021.772977772977Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field TestKe Zhu0Ke Zhu1Yifan Zeng2Yifan Zeng3Qiang Wu4Qiang Wu5Shengheng Xu6Shengheng Xu7Kun Tu8Kun Tu9Xiaoxiu Liu10Xiaoxiu Liu11College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaCollege of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing, ChinaNational Engineering Research Center of Coal Mine Water Hazard Controlling, Beijing, ChinaAlthough buildings are often heated and cooled by single-well circulation coupled groundwater heat pump systems, few studies have evaluated the long-term performance of these systems. Therefore, the present study investigated the performance of these systems by analyzing the efficiency and energy consumption using 4 years of operating data. The results indicate that the coefficient of performance (COP) of the system gradually decreases because of thermal breakthrough or an accumulation of cold. In addition, the sealing clapboards could effectively slow down thermal breakthrough. In addition, compared with the heating period, the COP of the heat pump unit (HPU) and system increases, and its energy consumption decreases in the cooling period. It was also found that partial heat loss occurs when water from the single-well circulation outlet penetrates the main pipeline. Moreover, the heat-exchange efficiency of a single HPU exceeds that of multiple HPUs, and the COP of a HPU decreases during operation with increasing indoor temperature. Accordingly, we improved the performance of system by increasing the underground heat storage. Herein, we focus on optimizing the system design during long-term operation, which includes taking steps such as lengthening the sealing clapboards, using insulated pipes, discharging the remaining water and adding intelligent control devices.https://www.frontiersin.org/articles/10.3389/feart.2021.772977/fullsingle-well circulationgroundwater heat pumpefficiencyenergy consumptioncoefficient of performance
spellingShingle Ke Zhu
Ke Zhu
Yifan Zeng
Yifan Zeng
Qiang Wu
Qiang Wu
Shengheng Xu
Shengheng Xu
Kun Tu
Kun Tu
Xiaoxiu Liu
Xiaoxiu Liu
Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
Frontiers in Earth Science
single-well circulation
groundwater heat pump
efficiency
energy consumption
coefficient of performance
title Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
title_full Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
title_fullStr Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
title_full_unstemmed Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
title_short Study on the Long-Term Performance and Efficiency of Single-Well Circulation Coupled Groundwater Heat Pump System Based on Field Test
title_sort study on the long term performance and efficiency of single well circulation coupled groundwater heat pump system based on field test
topic single-well circulation
groundwater heat pump
efficiency
energy consumption
coefficient of performance
url https://www.frontiersin.org/articles/10.3389/feart.2021.772977/full
work_keys_str_mv AT kezhu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT kezhu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT yifanzeng studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT yifanzeng studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT qiangwu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT qiangwu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT shenghengxu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT shenghengxu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT kuntu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT kuntu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT xiaoxiuliu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest
AT xiaoxiuliu studyonthelongtermperformanceandefficiencyofsinglewellcirculationcoupledgroundwaterheatpumpsystembasedonfieldtest