Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation

The corner impinging jet ventilation is a new air distribution system for use in office environments. This study reports the mean flow field behavior of dual isothermal corner-placed inlets based on an impinging jet in a square-shaped room with the size of 7.2 m × 7.2 m. A detailed numerical study i...

Full description

Bibliographic Details
Main Authors: Arman Ameen, Haruna Yamasawa, Tomohiro Kobayashi
Format: Article
Language:English
Published: MDPI AG 2022-10-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/10/1767
_version_ 1797474574060748800
author Arman Ameen
Haruna Yamasawa
Tomohiro Kobayashi
author_facet Arman Ameen
Haruna Yamasawa
Tomohiro Kobayashi
author_sort Arman Ameen
collection DOAJ
description The corner impinging jet ventilation is a new air distribution system for use in office environments. This study reports the mean flow field behavior of dual isothermal corner-placed inlets based on an impinging jet in a square-shaped room with the size of 7.2 m × 7.2 m. A detailed numerical study is carried out to evaluate the influence the different configuration parameters, such as the inlet placement, same side or opposite side, and supply airflow rate, have on the flow field. The results show that the highest velocity peak for all cases is obtained at <i>x</i> = 0.5 m and the lowest at <i>x</i> = 3.5 m. The velocity profiles development remains similar when increasing the flow rate. For the zone evaluation, the results show that Case 1 and 2 (V = 20 L/s) meet the requirement of not exceeding 0.15 m/s during the heating season in the occupied zone according the BBR standard both for same-side and opposite-side configurations. For Case 4, the optimal placement of the inlets is opposite to each other when V = 30 L/s for the BBR requirements. Case 1, 2, 3, 4, 5, and 7 all meet the requirement of not exceeding 0.25 m/s during the cooling season both for the same-side and opposite-side configurations. For Case 8, the optimal placement of the inlets is opposite to each other when V = 50 L/s.
first_indexed 2024-03-09T20:32:03Z
format Article
id doaj.art-70a0f1cdd0684d5a8a8904ae0fc82db4
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T20:32:03Z
publishDate 2022-10-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-70a0f1cdd0684d5a8a8904ae0fc82db42023-11-23T23:19:43ZengMDPI AGBuildings2075-53092022-10-011210176710.3390/buildings12101767Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building VentilationArman Ameen0Haruna Yamasawa1Tomohiro Kobayashi2Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, University of Gävle, 801 76 Gävle, SwedenFaculty of Engineering Sciences, Department of Advanced Environmental Science and Engineering, Kyushu University, 6-1 Kasuga-koen, Kasuga 816-8580, JapanDepartment of Architectural Engineering, Division of Global Architecture, Osaka University, 2-1 Yamadaoka, Suita 565-0871, JapanThe corner impinging jet ventilation is a new air distribution system for use in office environments. This study reports the mean flow field behavior of dual isothermal corner-placed inlets based on an impinging jet in a square-shaped room with the size of 7.2 m × 7.2 m. A detailed numerical study is carried out to evaluate the influence the different configuration parameters, such as the inlet placement, same side or opposite side, and supply airflow rate, have on the flow field. The results show that the highest velocity peak for all cases is obtained at <i>x</i> = 0.5 m and the lowest at <i>x</i> = 3.5 m. The velocity profiles development remains similar when increasing the flow rate. For the zone evaluation, the results show that Case 1 and 2 (V = 20 L/s) meet the requirement of not exceeding 0.15 m/s during the heating season in the occupied zone according the BBR standard both for same-side and opposite-side configurations. For Case 4, the optimal placement of the inlets is opposite to each other when V = 30 L/s for the BBR requirements. Case 1, 2, 3, 4, 5, and 7 all meet the requirement of not exceeding 0.25 m/s during the cooling season both for the same-side and opposite-side configurations. For Case 8, the optimal placement of the inlets is opposite to each other when V = 50 L/s.https://www.mdpi.com/2075-5309/12/10/1767dual-corner impinging jet ventilationcomputational fluid dynamicinlet configuration
spellingShingle Arman Ameen
Haruna Yamasawa
Tomohiro Kobayashi
Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
Buildings
dual-corner impinging jet ventilation
computational fluid dynamic
inlet configuration
title Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
title_full Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
title_fullStr Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
title_full_unstemmed Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
title_short Numerical Evaluation of the Flow Field of an Isothermal Dual-Corner Impinging Jet for Building Ventilation
title_sort numerical evaluation of the flow field of an isothermal dual corner impinging jet for building ventilation
topic dual-corner impinging jet ventilation
computational fluid dynamic
inlet configuration
url https://www.mdpi.com/2075-5309/12/10/1767
work_keys_str_mv AT armanameen numericalevaluationoftheflowfieldofanisothermaldualcornerimpingingjetforbuildingventilation
AT harunayamasawa numericalevaluationoftheflowfieldofanisothermaldualcornerimpingingjetforbuildingventilation
AT tomohirokobayashi numericalevaluationoftheflowfieldofanisothermaldualcornerimpingingjetforbuildingventilation