Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry

Background and aims: Undoubtedly, noise and vibration are major problems of industrial world and lot of people are very exposed to these phenomena in their workplace or residential areas. Researchers have shown that exposure to noise may increase the risks related to personal health, like nervous fr...

Full description

Bibliographic Details
Main Authors: Gholam Abbas Shirali, Sanaz Karimpour, Davod Afshari
Format: Article
Language:fas
Published: Iran University of Medical Sciences 2019-04-01
Series:Salāmat-i kār-i Īrān
Subjects:
Online Access:http://ioh.iums.ac.ir/article-1-2336-en.html
_version_ 1818936531983794176
author Gholam Abbas Shirali
Sanaz Karimpour
Davod Afshari
author_facet Gholam Abbas Shirali
Sanaz Karimpour
Davod Afshari
author_sort Gholam Abbas Shirali
collection DOAJ
description Background and aims: Undoubtedly, noise and vibration are major problems of industrial world and lot of people are very exposed to these phenomena in their workplace or residential areas. Researchers have shown that exposure to noise may increase the risks related to personal health, like nervous frailty, extreme irritability, muscle cramps, stress and anxiety, dizziness, headache and migraine, anger, loss of body balance, vomiting, pain, hypertension, high blood pressure, cardiovascular problems, deterioration of sleep quality, mental stress, etc. However, the purpose of this study was to assess and control and reduce the risks resulting from noise in the reduction unit 2 of a steel industry. Methods: This study was conducted in two steps. 1) Evaluation of noise pollution in the compressor room and its surrounding: For this purpose, total sound pressure level (SPL) and SPLpeak were measured in the places where workers worked or were traveled. The parameters were measured in the mentioned places according to a grid pattern in both the compressor turn on/off. Because the workers exposed to a noise fluctuating, in addition to SPL analysis on the octave-band frequencies to determine critical frequency when the compressor was switched on, the value of Leq was also measured. The critical frequency is very important in noise control issues. The measurements were performed by using sound level meter, model of “B&K 2231.” The apparatus was calibrated before and after measurements by using “B&K 4230 calibrator.” 2) Noise control measurements: After identifying noise leakage paths to outside of the compressor room, noise was controlled in door, wall-fans and roof window area through installing a silencer on the wall-fans and redesigning the door and the roof window using the previous step data. Results: Inside the compressor room, the total sound pressure level and the critical frequency was estimated 106.2 dB (A) and of 250 Hz in the Lin network, respectively. The total sound pressure level in the area around the compressor and the critical frequency were also estimated 94.3 dB (A) and 2000 Hz respectively. Moreover, the value of Leq was more than the threshold value (<85 dB) at all measured stations. In order to control the noise in the area of ​​the fans, considering the noise assessment and the critical frequency, there was used an absorption silencer with glass wool as adsorbent material. To control noise at the door and roof window, there was designed and installed a steel door with dimensions of 3.9 * 2.13 meter and thickness of 1.5 mm which was filled by a noise-adsorbent 40 mm of glass wool and attached to a metal grid. Moreover, to control noise in the roof window was applied a structure with the same specifications, but with the different dimensions (4.2 * 4.2 m and 7 mm mesh diameter). However, the results related to before and after implementation of the control measurements showed an acceptable attenuation in the SPL (91.8%). The average SPL before and after implementation of the control measurements was 95 and 87.2 dBA, respectively which this value was an acceptable level in comparison with background noise, i.e., 86.4 dBA. On the other hand, The slight difference between the mean value of the background sound pressure level and the average of controlled sound pressure level (0.8 dB) is due to factors such as temperature, variations in sound at different positions, generated noise sources (off or on and so no) and the movement of fluids in the pipes and so on.   Conclusion: The results of the field study indicated that door, window and roof window were identified as the main paths of noise leakage to outside of the compressor room. Therefore, the implementation of the control measurements could be reduced to an acceptable level, but due to high background noise level even after the implementation of the control measurements, the noise level was less higher than the maximum permissible level (85 dB). Therefore, there were presented a few recommendations such as controlling the other sources of noise (e.g. moving fluid through pipes), utilizing the hearing protection devices and how to choose them properly to reduce background noise and the protection of workers against noise.
first_indexed 2024-12-20T05:37:33Z
format Article
id doaj.art-70b1ffc6e7b1425e89fb6cf6e2f4660d
institution Directory Open Access Journal
issn 1735-5133
2228-7493
language fas
last_indexed 2024-12-20T05:37:33Z
publishDate 2019-04-01
publisher Iran University of Medical Sciences
record_format Article
series Salāmat-i kār-i Īrān
spelling doaj.art-70b1ffc6e7b1425e89fb6cf6e2f4660d2022-12-21T19:51:33ZfasIran University of Medical SciencesSalāmat-i kār-i Īrān1735-51332228-74932019-04-0116190101Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel IndustryGholam Abbas Shirali0Sanaz Karimpour1Davod Afshari2 Ahvaz Jundishapur University of Medical Sciences Ahvaz Jundishapur University of Medical Sciences Ahvaz Jundishapur University of Medical Sciences Background and aims: Undoubtedly, noise and vibration are major problems of industrial world and lot of people are very exposed to these phenomena in their workplace or residential areas. Researchers have shown that exposure to noise may increase the risks related to personal health, like nervous frailty, extreme irritability, muscle cramps, stress and anxiety, dizziness, headache and migraine, anger, loss of body balance, vomiting, pain, hypertension, high blood pressure, cardiovascular problems, deterioration of sleep quality, mental stress, etc. However, the purpose of this study was to assess and control and reduce the risks resulting from noise in the reduction unit 2 of a steel industry. Methods: This study was conducted in two steps. 1) Evaluation of noise pollution in the compressor room and its surrounding: For this purpose, total sound pressure level (SPL) and SPLpeak were measured in the places where workers worked or were traveled. The parameters were measured in the mentioned places according to a grid pattern in both the compressor turn on/off. Because the workers exposed to a noise fluctuating, in addition to SPL analysis on the octave-band frequencies to determine critical frequency when the compressor was switched on, the value of Leq was also measured. The critical frequency is very important in noise control issues. The measurements were performed by using sound level meter, model of “B&K 2231.” The apparatus was calibrated before and after measurements by using “B&K 4230 calibrator.” 2) Noise control measurements: After identifying noise leakage paths to outside of the compressor room, noise was controlled in door, wall-fans and roof window area through installing a silencer on the wall-fans and redesigning the door and the roof window using the previous step data. Results: Inside the compressor room, the total sound pressure level and the critical frequency was estimated 106.2 dB (A) and of 250 Hz in the Lin network, respectively. The total sound pressure level in the area around the compressor and the critical frequency were also estimated 94.3 dB (A) and 2000 Hz respectively. Moreover, the value of Leq was more than the threshold value (<85 dB) at all measured stations. In order to control the noise in the area of ​​the fans, considering the noise assessment and the critical frequency, there was used an absorption silencer with glass wool as adsorbent material. To control noise at the door and roof window, there was designed and installed a steel door with dimensions of 3.9 * 2.13 meter and thickness of 1.5 mm which was filled by a noise-adsorbent 40 mm of glass wool and attached to a metal grid. Moreover, to control noise in the roof window was applied a structure with the same specifications, but with the different dimensions (4.2 * 4.2 m and 7 mm mesh diameter). However, the results related to before and after implementation of the control measurements showed an acceptable attenuation in the SPL (91.8%). The average SPL before and after implementation of the control measurements was 95 and 87.2 dBA, respectively which this value was an acceptable level in comparison with background noise, i.e., 86.4 dBA. On the other hand, The slight difference between the mean value of the background sound pressure level and the average of controlled sound pressure level (0.8 dB) is due to factors such as temperature, variations in sound at different positions, generated noise sources (off or on and so no) and the movement of fluids in the pipes and so on.   Conclusion: The results of the field study indicated that door, window and roof window were identified as the main paths of noise leakage to outside of the compressor room. Therefore, the implementation of the control measurements could be reduced to an acceptable level, but due to high background noise level even after the implementation of the control measurements, the noise level was less higher than the maximum permissible level (85 dB). Therefore, there were presented a few recommendations such as controlling the other sources of noise (e.g. moving fluid through pipes), utilizing the hearing protection devices and how to choose them properly to reduce background noise and the protection of workers against noise.http://ioh.iums.ac.ir/article-1-2336-en.htmlnoisecontrolassessmentcompressor
spellingShingle Gholam Abbas Shirali
Sanaz Karimpour
Davod Afshari
Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
Salāmat-i kār-i Īrān
noise
control
assessment
compressor
title Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
title_full Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
title_fullStr Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
title_full_unstemmed Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
title_short Assessment and Control of Noise Pollution in Seal Gas Compressor of Reduction Unit 2 of a Steel Industry
title_sort assessment and control of noise pollution in seal gas compressor of reduction unit 2 of a steel industry
topic noise
control
assessment
compressor
url http://ioh.iums.ac.ir/article-1-2336-en.html
work_keys_str_mv AT gholamabbasshirali assessmentandcontrolofnoisepollutioninsealgascompressorofreductionunit2ofasteelindustry
AT sanazkarimpour assessmentandcontrolofnoisepollutioninsealgascompressorofreductionunit2ofasteelindustry
AT davodafshari assessmentandcontrolofnoisepollutioninsealgascompressorofreductionunit2ofasteelindustry