Factors that affect mass transport from drug eluting stents into the artery wall

<p>Abstract</p> <p>Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-bl...

Full description

Bibliographic Details
Main Authors: Walsh Michael T, McGloughlin Tim M, O'Connell Barry M
Format: Article
Language:English
Published: BMC 2010-03-01
Series:BioMedical Engineering OnLine
Online Access:http://www.biomedical-engineering-online.com/content/9/1/15
_version_ 1818524744572469248
author Walsh Michael T
McGloughlin Tim M
O'Connell Barry M
author_facet Walsh Michael T
McGloughlin Tim M
O'Connell Barry M
author_sort Walsh Michael T
collection DOAJ
description <p>Abstract</p> <p>Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.</p>
first_indexed 2024-12-11T06:00:54Z
format Article
id doaj.art-70c6e38416b543bfa3bb92938c2662c6
institution Directory Open Access Journal
issn 1475-925X
language English
last_indexed 2024-12-11T06:00:54Z
publishDate 2010-03-01
publisher BMC
record_format Article
series BioMedical Engineering OnLine
spelling doaj.art-70c6e38416b543bfa3bb92938c2662c62022-12-22T01:18:29ZengBMCBioMedical Engineering OnLine1475-925X2010-03-01911510.1186/1475-925X-9-15Factors that affect mass transport from drug eluting stents into the artery wallWalsh Michael TMcGloughlin Tim MO'Connell Barry M<p>Abstract</p> <p>Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy.</p>http://www.biomedical-engineering-online.com/content/9/1/15
spellingShingle Walsh Michael T
McGloughlin Tim M
O'Connell Barry M
Factors that affect mass transport from drug eluting stents into the artery wall
BioMedical Engineering OnLine
title Factors that affect mass transport from drug eluting stents into the artery wall
title_full Factors that affect mass transport from drug eluting stents into the artery wall
title_fullStr Factors that affect mass transport from drug eluting stents into the artery wall
title_full_unstemmed Factors that affect mass transport from drug eluting stents into the artery wall
title_short Factors that affect mass transport from drug eluting stents into the artery wall
title_sort factors that affect mass transport from drug eluting stents into the artery wall
url http://www.biomedical-engineering-online.com/content/9/1/15
work_keys_str_mv AT walshmichaelt factorsthataffectmasstransportfromdrugelutingstentsintothearterywall
AT mcgloughlintimm factorsthataffectmasstransportfromdrugelutingstentsintothearterywall
AT oconnellbarrym factorsthataffectmasstransportfromdrugelutingstentsintothearterywall