STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA

This study highlights the management of electrical equipment and waste electrical equipment with PCB content inventoried in Romania. Because it is mandatory to phase out such equipment with concentrations of at least 50 ppm at a volume of more than 5 dm3 an assessment of the compliance with the requ...

Full description

Bibliographic Details
Main Authors: Irina SMICAL, Olivian CHIVER
Format: Article
Language:English
Published: Technical University of Cluj-Napoca 2021-12-01
Series:Carpathian Journal of Electrical Engineering
Subjects:
Online Access:http://cee.cunbm.utcluj.ro/wp-content/uploads/CJEE20211.pdf
_version_ 1811290263855824896
author Irina SMICAL
Olivian CHIVER
author_facet Irina SMICAL
Olivian CHIVER
author_sort Irina SMICAL
collection DOAJ
description This study highlights the management of electrical equipment and waste electrical equipment with PCB content inventoried in Romania. Because it is mandatory to phase out such equipment with concentrations of at least 50 ppm at a volume of more than 5 dm3 an assessment of the compliance with the requirements imposed by the specific legislation has been made. The results obtained from the statistical processing and interpretation of the data from the national inventory reveal that in Romania, the elimination process is slow and that are still important stocks of equipment with PCB content that must be eliminated. By the end of 2018, the rate of decontamination and disposal of this equipment and the quantities of oils with PCB content was below 25%. Currently, there is no national or county inventory of fluid-containing equipment with 0.005% to 0.05% PCB relative to fluid weight. In Maramureș County, there is no waste electrical equipment in the inventory with PCB content, but only capacitors in use. By the end of 2019, the rate of decontamination and disposal of these equipments at county level was below 15%.
first_indexed 2024-04-13T04:09:50Z
format Article
id doaj.art-71129344085746d89cf14c499d261710
institution Directory Open Access Journal
issn 1843-7583
language English
last_indexed 2024-04-13T04:09:50Z
publishDate 2021-12-01
publisher Technical University of Cluj-Napoca
record_format Article
series Carpathian Journal of Electrical Engineering
spelling doaj.art-71129344085746d89cf14c499d2617102022-12-22T03:03:08ZengTechnical University of Cluj-NapocaCarpathian Journal of Electrical Engineering1843-75832021-12-01151727STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIAIrina SMICAL0Olivian CHIVER1Technical University of Cluj-NapocaTechnical University of Cluj-NapocaThis study highlights the management of electrical equipment and waste electrical equipment with PCB content inventoried in Romania. Because it is mandatory to phase out such equipment with concentrations of at least 50 ppm at a volume of more than 5 dm3 an assessment of the compliance with the requirements imposed by the specific legislation has been made. The results obtained from the statistical processing and interpretation of the data from the national inventory reveal that in Romania, the elimination process is slow and that are still important stocks of equipment with PCB content that must be eliminated. By the end of 2018, the rate of decontamination and disposal of this equipment and the quantities of oils with PCB content was below 25%. Currently, there is no national or county inventory of fluid-containing equipment with 0.005% to 0.05% PCB relative to fluid weight. In Maramureș County, there is no waste electrical equipment in the inventory with PCB content, but only capacitors in use. By the end of 2019, the rate of decontamination and disposal of these equipments at county level was below 15%.http://cee.cunbm.utcluj.ro/wp-content/uploads/CJEE20211.pdfequipment and waste electrical equipmenttransformercapacitorpcbcontamination
spellingShingle Irina SMICAL
Olivian CHIVER
STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
Carpathian Journal of Electrical Engineering
equipment and waste electrical equipment
transformer
capacitor
pcb
contamination
title STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
title_full STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
title_fullStr STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
title_full_unstemmed STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
title_short STUDY ON THE MANAGEMENT OF ELECTRICAL EQUIPMENT AND WASTE ELECTRICAL EQUIPMENT WITH PCB CONTENT IN MARAMUREȘ COUNTY, ROMANIA
title_sort study on the management of electrical equipment and waste electrical equipment with pcb content in maramures county romania
topic equipment and waste electrical equipment
transformer
capacitor
pcb
contamination
url http://cee.cunbm.utcluj.ro/wp-content/uploads/CJEE20211.pdf
work_keys_str_mv AT irinasmical studyonthemanagementofelectricalequipmentandwasteelectricalequipmentwithpcbcontentinmaramurescountyromania
AT olivianchiver studyonthemanagementofelectricalequipmentandwasteelectricalequipmentwithpcbcontentinmaramurescountyromania