Lock-in thermography for characterization of nuclear materials
A simplified procedure of lock-in thermography was developed and applied for characterization of nuclear materials. The possibility of thickness and thermal diffusivity measurements with the accuracy better than 90% was demonstrated with different metals and Zircaloy-4 claddings.
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2016-01-01
|
Series: | EPJ Nuclear Sciences & Technologies |
Online Access: | http://dx.doi.org/10.1051/epjn/2016015 |
_version_ | 1819275120433168384 |
---|---|
author | Semerok Alexandre Pham Tu Quoc Sang Cheymol Guy Gallou Catherine Maskrot Hicham Moutiers Gilles |
author_facet | Semerok Alexandre Pham Tu Quoc Sang Cheymol Guy Gallou Catherine Maskrot Hicham Moutiers Gilles |
author_sort | Semerok Alexandre |
collection | DOAJ |
description | A simplified procedure of lock-in thermography was developed and applied for characterization of nuclear materials. The possibility of thickness and thermal diffusivity measurements with the accuracy better than 90% was demonstrated with different metals and Zircaloy-4 claddings. |
first_indexed | 2024-12-23T23:19:16Z |
format | Article |
id | doaj.art-71b7af149db44b43bd85331fa6517715 |
institution | Directory Open Access Journal |
issn | 2491-9292 |
language | English |
last_indexed | 2024-12-23T23:19:16Z |
publishDate | 2016-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | EPJ Nuclear Sciences & Technologies |
spelling | doaj.art-71b7af149db44b43bd85331fa65177152022-12-21T17:26:23ZengEDP SciencesEPJ Nuclear Sciences & Technologies2491-92922016-01-0122010.1051/epjn/2016015epjn150054Lock-in thermography for characterization of nuclear materialsSemerok AlexandrePham Tu Quoc SangCheymol GuyGallou CatherineMaskrot HichamMoutiers GillesA simplified procedure of lock-in thermography was developed and applied for characterization of nuclear materials. The possibility of thickness and thermal diffusivity measurements with the accuracy better than 90% was demonstrated with different metals and Zircaloy-4 claddings.http://dx.doi.org/10.1051/epjn/2016015 |
spellingShingle | Semerok Alexandre Pham Tu Quoc Sang Cheymol Guy Gallou Catherine Maskrot Hicham Moutiers Gilles Lock-in thermography for characterization of nuclear materials EPJ Nuclear Sciences & Technologies |
title | Lock-in thermography for characterization of nuclear materials |
title_full | Lock-in thermography for characterization of nuclear materials |
title_fullStr | Lock-in thermography for characterization of nuclear materials |
title_full_unstemmed | Lock-in thermography for characterization of nuclear materials |
title_short | Lock-in thermography for characterization of nuclear materials |
title_sort | lock in thermography for characterization of nuclear materials |
url | http://dx.doi.org/10.1051/epjn/2016015 |
work_keys_str_mv | AT semerokalexandre lockinthermographyforcharacterizationofnuclearmaterials AT phamtuquocsang lockinthermographyforcharacterizationofnuclearmaterials AT cheymolguy lockinthermographyforcharacterizationofnuclearmaterials AT galloucatherine lockinthermographyforcharacterizationofnuclearmaterials AT maskrothicham lockinthermographyforcharacterizationofnuclearmaterials AT moutiersgilles lockinthermographyforcharacterizationofnuclearmaterials |