Abstract Background The recently described ‘critical trochanter angle’ (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability...

Full description

Bibliographic Details
Main Authors: Sebastian Serong, Moritz Schutzbach, Ivica Zovko, Marcus Jäger, Stefan Landgraeber, Marcel Haversath
Format: Article
Language:English
Published: BMC 2020-12-01
Series:European Journal of Medical Research
Subjects:
Online Access:https://doi.org/10.1186/s40001-020-00469-4
_version_ 1818329650335580160
author Sebastian Serong
Moritz Schutzbach
Ivica Zovko
Marcus Jäger
Stefan Landgraeber
Marcel Haversath
author_facet Sebastian Serong
Moritz Schutzbach
Ivica Zovko
Marcus Jäger
Stefan Landgraeber
Marcel Haversath
author_sort Sebastian Serong
collection DOAJ
description Abstract Background The recently described ‘critical trochanter angle’ (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability. It is hypothesized that both analyses justify the clinical use of the CTA. Methods A total of 100 pelvic radiographs obtained prior to total hip arthroplasty were retrospectively reviewed by four observers with different levels of clinical experience. The CTA was measured twice by each observer at different occasions in the previously described technique. Intra- and interobserver reliability was evaluated using intraclass correlation coefficients (ICC) with confidence intervals (CI) and the Bland–Altman approach. Results The mean CTA in both measuring sequences was 20.58° and 20.78°. The observers’ means ranged from 17.76° to 25.23°. Intraobserver reliability showed a mean difference of less than 0.5° for all four observers (95% limit of agreement: − 7.70–6.70). Intraobserver ICCs ranged from 0.92 to 0.99 (CI 0.88–0.99). For interobserver variation analysis, ICCs of 0.83 (CI 0.67–0.90) and 0.85 (CI 0.68–0.92) were calculated. Conclusion Analyses concerning intra- and interobserver reliability in the assessment of the CTA showed ‘very good’ and ‘good’ results, respectively. In view of these findings, the use of the CTA as an additional preoperative parameter to assess the risk of intraoperative stem malalignment seems to be justified.
first_indexed 2024-12-13T12:51:26Z
format Article
id doaj.art-71e5510151a74e04a14c9f4c773ebd41
institution Directory Open Access Journal
issn 2047-783X
language English
last_indexed 2024-12-13T12:51:26Z
publishDate 2020-12-01
publisher BMC
record_format Article
series European Journal of Medical Research
spelling doaj.art-71e5510151a74e04a14c9f4c773ebd412022-12-21T23:45:19ZengBMCEuropean Journal of Medical Research2047-783X2020-12-012511610.1186/s40001-020-00469-4Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’Sebastian Serong0Moritz Schutzbach1Ivica Zovko2Marcus Jäger3Stefan Landgraeber4Marcel Haversath5Department of Orthopaedics & Orthopaedic Surgery, Saarland UniversityDepartment of Orthopaedics & Traumatology, University of Duisburg-EssenDepartment of Orthopaedics & Traumatology, University of Duisburg-EssenDepartment of Orthopaedics, Trauma and Reconstructive Surgery, St. Marien Hospital Mülheim/Chair of Orthopaedics and Trauma Surgery, University of Duisburg-EssenDepartment of Orthopaedics & Orthopaedic Surgery, Saarland UniversityDepartment of Orthopaedics & Traumatology, University of Duisburg-EssenAbstract Background The recently described ‘critical trochanter angle’ (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability. It is hypothesized that both analyses justify the clinical use of the CTA. Methods A total of 100 pelvic radiographs obtained prior to total hip arthroplasty were retrospectively reviewed by four observers with different levels of clinical experience. The CTA was measured twice by each observer at different occasions in the previously described technique. Intra- and interobserver reliability was evaluated using intraclass correlation coefficients (ICC) with confidence intervals (CI) and the Bland–Altman approach. Results The mean CTA in both measuring sequences was 20.58° and 20.78°. The observers’ means ranged from 17.76° to 25.23°. Intraobserver reliability showed a mean difference of less than 0.5° for all four observers (95% limit of agreement: − 7.70–6.70). Intraobserver ICCs ranged from 0.92 to 0.99 (CI 0.88–0.99). For interobserver variation analysis, ICCs of 0.83 (CI 0.67–0.90) and 0.85 (CI 0.68–0.92) were calculated. Conclusion Analyses concerning intra- and interobserver reliability in the assessment of the CTA showed ‘very good’ and ‘good’ results, respectively. In view of these findings, the use of the CTA as an additional preoperative parameter to assess the risk of intraoperative stem malalignment seems to be justified.https://doi.org/10.1186/s40001-020-00469-4Critical trochanter angleTotal hip arthroplastyStem alignmentIntraobserverInterobserverReliability
spellingShingle Sebastian Serong
Moritz Schutzbach
Ivica Zovko
Marcus Jäger
Stefan Landgraeber
Marcel Haversath
Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
European Journal of Medical Research
Critical trochanter angle
Total hip arthroplasty
Stem alignment
Intraobserver
Interobserver
Reliability
title Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
title_full Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
title_fullStr Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
title_full_unstemmed Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
title_short Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
title_sort evaluation of intra and interobserver reliability in the assessment of the critical trochanter angle
topic Critical trochanter angle
Total hip arthroplasty
Stem alignment
Intraobserver
Interobserver
Reliability
url https://doi.org/10.1186/s40001-020-00469-4
work_keys_str_mv AT sebastianserong evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle
AT moritzschutzbach evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle
AT ivicazovko evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle
AT marcusjager evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle
AT stefanlandgraeber evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle
AT marcelhaversath evaluationofintraandinterobserverreliabilityintheassessmentofthecriticaltrochanterangle