The Quest for Quality Electrocardiographic Recording
For correct electrocardiography ECG diagnosis and interpretation, it is important not only to distinguish normal from pathological electrocardiograms, but also to ensure they have been properly recorded. Heden et al, reported that 2% of 11,000 EEGs analyzed showed interchanged electrode placement...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
University Library System, University of Pittsburgh
2015-10-01
|
Series: | International Journal of Medical Students |
Subjects: | |
Online Access: | http://www.ijms.info/ojs/index.php/IJMS/article/view/189 |
_version_ | 1797724116415938560 |
---|---|
author | Javier García-Niebla |
author_facet | Javier García-Niebla |
author_sort | Javier García-Niebla |
collection | DOAJ |
description | For correct electrocardiography ECG diagnosis and interpretation, it is important not only to distinguish normal from pathological electrocardiograms, but also to ensure they have been properly recorded.
Heden et al, reported that 2% of 11,000 EEGs analyzed showed interchanged electrode placement. Thus, if 300 million ECGs are performed annually in the world, 6 million are erroneously recorded. This figure could even triple if one includes other frequent mistakes, such as vertical displacement of precordial electrodes and the proximal placement of these on the limbs instead of the trunk. Few manuals on electrocardiography have devoted space to warn about the effects of ECG recordings that do not conform to standards, but it seems that this is changing.
This issue of the journal contains two interesting articles by Rosen et al., who form part of the research group led by Dr. Adrian Baranchuk, which address the most common mistakes made in daily practice in relation to improper placement of limb and precordial electrodes, as well as tell-tale signs for their detection.
In this editorial we will elaborate on certain issues directly related to possible errors on performing an ECG. |
first_indexed | 2024-03-12T10:12:47Z |
format | Article |
id | doaj.art-72989e7b66154b259daba006c0d20787 |
institution | Directory Open Access Journal |
issn | 2076-6327 |
language | English |
last_indexed | 2024-03-12T10:12:47Z |
publishDate | 2015-10-01 |
publisher | University Library System, University of Pittsburgh |
record_format | Article |
series | International Journal of Medical Students |
spelling | doaj.art-72989e7b66154b259daba006c0d207872023-09-02T10:45:38ZengUniversity Library System, University of PittsburghInternational Journal of Medical Students2076-63272015-10-01238789The Quest for Quality Electrocardiographic RecordingJavier García-Niebla0Servicios Sanitarios del Área de Salud de El Hierro, Valle del Golfo Health Center. Ex-member of the Board of Directors, Spanish Association of Nursing in Cardiology. Collaborating lecturer of the University School of Nursing. University Hospital La. Candelaria, Spain.For correct electrocardiography ECG diagnosis and interpretation, it is important not only to distinguish normal from pathological electrocardiograms, but also to ensure they have been properly recorded. Heden et al, reported that 2% of 11,000 EEGs analyzed showed interchanged electrode placement. Thus, if 300 million ECGs are performed annually in the world, 6 million are erroneously recorded. This figure could even triple if one includes other frequent mistakes, such as vertical displacement of precordial electrodes and the proximal placement of these on the limbs instead of the trunk. Few manuals on electrocardiography have devoted space to warn about the effects of ECG recordings that do not conform to standards, but it seems that this is changing. This issue of the journal contains two interesting articles by Rosen et al., who form part of the research group led by Dr. Adrian Baranchuk, which address the most common mistakes made in daily practice in relation to improper placement of limb and precordial electrodes, as well as tell-tale signs for their detection. In this editorial we will elaborate on certain issues directly related to possible errors on performing an ECG.http://www.ijms.info/ojs/index.php/IJMS/article/view/189ElectrocardiographyElectrode misplacementQuality ECG recording |
spellingShingle | Javier García-Niebla The Quest for Quality Electrocardiographic Recording International Journal of Medical Students Electrocardiography Electrode misplacement Quality ECG recording |
title | The Quest for Quality Electrocardiographic Recording |
title_full | The Quest for Quality Electrocardiographic Recording |
title_fullStr | The Quest for Quality Electrocardiographic Recording |
title_full_unstemmed | The Quest for Quality Electrocardiographic Recording |
title_short | The Quest for Quality Electrocardiographic Recording |
title_sort | quest for quality electrocardiographic recording |
topic | Electrocardiography Electrode misplacement Quality ECG recording |
url | http://www.ijms.info/ojs/index.php/IJMS/article/view/189 |
work_keys_str_mv | AT javiergarcianiebla thequestforqualityelectrocardiographicrecording AT javiergarcianiebla questforqualityelectrocardiographicrecording |