Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network
Distribution transformer is one of the most important power equipments in distribution network, whose running state exercises a great influence on the stability of the network. Transformer Terminal Unit (TTU) is an effective device to monitor the running state of transformers in the distribution aut...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Banja Luka
2013-12-01
|
Series: | Electronics |
Subjects: | |
Online Access: | http://electronics.etfbl.net/journal/Vol17No2/xPaper_12.pdf |
_version_ | 1811304299416780800 |
---|---|
author | Na Wu Yinjing Guo Yongqin Wei Aying Wei |
author_facet | Na Wu Yinjing Guo Yongqin Wei Aying Wei |
author_sort | Na Wu |
collection | DOAJ |
description | Distribution transformer is one of the most important power equipments in distribution network, whose running state exercises a great influence on the stability of the network. Transformer Terminal Unit (TTU) is an effective device to monitor the running state of transformers in the distribution automation system. In this paper, we study a new smart TTU which uses ARM7 series chip as processor, equipped with ATT7022B based electric meter module and GPRS module for remote data transmission control. We focus on the corresponding hardware, software design and the measurement principle of harmonics of TTU. The new TTU can measure the electric parameters of the distribution transformer precisely. Taking advantage of the powerful ARM processor, it can analyze harmonic of the power line effectively. Due to the always-on-line feature of GPRS, TTU can achieve reliable communication with the remote terminal and the master station. Compared with other similar units, the new unit outperforms in terms of real-time,
precision and reliability, which can fully meet with the high-speed
development of distribution automation system. |
first_indexed | 2024-04-13T08:03:34Z |
format | Article |
id | doaj.art-72c0e77412934eea9b11a8e79cdd36e4 |
institution | Directory Open Access Journal |
issn | 1450-5843 1450-5843 |
language | English |
last_indexed | 2024-04-13T08:03:34Z |
publishDate | 2013-12-01 |
publisher | University of Banja Luka |
record_format | Article |
series | Electronics |
spelling | doaj.art-72c0e77412934eea9b11a8e79cdd36e42022-12-22T02:55:13ZengUniversity of Banja LukaElectronics1450-58431450-58432013-12-0117214414910.7251/ELS1317144WStudy on New Smart Transformer Terminal Unit Based on ARM and GPRS NetworkNa Wu0Yinjing Guo1Yongqin Wei2Aying Wei3College of Information and Electrical Engineering, Shandong University of Science and Technology, Qingdao, Shandong ChinaCollege of Information and Electrical Engineering, Shandong University of Science and Technology, Qingdao, Shandong ChinaCollege of Information and Electrical Engineering, Shandong University of Science and Technology, Qingdao, Shandong ChinaCollege of Information and Electrical Engineering, Shandong University of Science and Technology, Qingdao, Shandong ChinaDistribution transformer is one of the most important power equipments in distribution network, whose running state exercises a great influence on the stability of the network. Transformer Terminal Unit (TTU) is an effective device to monitor the running state of transformers in the distribution automation system. In this paper, we study a new smart TTU which uses ARM7 series chip as processor, equipped with ATT7022B based electric meter module and GPRS module for remote data transmission control. We focus on the corresponding hardware, software design and the measurement principle of harmonics of TTU. The new TTU can measure the electric parameters of the distribution transformer precisely. Taking advantage of the powerful ARM processor, it can analyze harmonic of the power line effectively. Due to the always-on-line feature of GPRS, TTU can achieve reliable communication with the remote terminal and the master station. Compared with other similar units, the new unit outperforms in terms of real-time, precision and reliability, which can fully meet with the high-speed development of distribution automation system.http://electronics.etfbl.net/journal/Vol17No2/xPaper_12.pdfARMGPRSATT7022BTransformer Terminal Unit (TTU) |
spellingShingle | Na Wu Yinjing Guo Yongqin Wei Aying Wei Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network Electronics ARM GPRS ATT7022B Transformer Terminal Unit (TTU) |
title | Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network |
title_full | Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network |
title_fullStr | Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network |
title_full_unstemmed | Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network |
title_short | Study on New Smart Transformer Terminal Unit Based on ARM and GPRS Network |
title_sort | study on new smart transformer terminal unit based on arm and gprs network |
topic | ARM GPRS ATT7022B Transformer Terminal Unit (TTU) |
url | http://electronics.etfbl.net/journal/Vol17No2/xPaper_12.pdf |
work_keys_str_mv | AT nawu studyonnewsmarttransformerterminalunitbasedonarmandgprsnetwork AT yinjingguo studyonnewsmarttransformerterminalunitbasedonarmandgprsnetwork AT yongqinwei studyonnewsmarttransformerterminalunitbasedonarmandgprsnetwork AT ayingwei studyonnewsmarttransformerterminalunitbasedonarmandgprsnetwork |