Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera

Power quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on the IEEE 1159-1995 standard, voltage sag is a...

Full description

Bibliographic Details
Main Authors: Hamzah Eteruddin, Hendry Hendry, Atmam Atmam
Format: Article
Language:English
Published: Universitas Riau 2018-11-01
Series:International Journal of Electrical, Energy and Power System Engineering
Subjects:
Online Access:https://ijeepse.id/journal/index.php/ijeepse/article/view/10
_version_ 1818235663764422656
author Hamzah Eteruddin
Hendry Hendry
Atmam Atmam
author_facet Hamzah Eteruddin
Hendry Hendry
Atmam Atmam
author_sort Hamzah Eteruddin
collection DOAJ
description Power quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on the IEEE 1159-1995 standard, voltage sag is a decrease in RMS voltage with duration of 0.5 cycle to 1 minute. Sag voltage that occurs can have an effect on electronic equipment and other problems that often arise in the industrial environment. Therefore, a short circuit fault analysis was conducted to determine the voltage sag based on the type of fault in the sub system in Central Sumatera. Short circuit fault analysis is done using Powerworld Simulator 7.0 Students Edition. This study is intended to determine the sag voltage when there is a short circuit fault. The biggest voltage sag occurs when a short circuit fault of single phase to ground at 75% fault location and the smallest voltage sag when the three-phase short circuit of 0.7 fault location.
first_indexed 2024-12-12T11:57:33Z
format Article
id doaj.art-72fc230478d341638968608f685f0199
institution Directory Open Access Journal
issn 2654-4644
language English
last_indexed 2024-12-12T11:57:33Z
publishDate 2018-11-01
publisher Universitas Riau
record_format Article
series International Journal of Electrical, Energy and Power System Engineering
spelling doaj.art-72fc230478d341638968608f685f01992022-12-22T00:25:10ZengUniversitas RiauInternational Journal of Electrical, Energy and Power System Engineering2654-46442018-11-01121510.31258/ijeepse.1.2.1-510Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central SumateraHamzah Eteruddin0Hendry Hendry1Atmam Atmam2Universitas Lancang Kuning, IndonesiaUniversitas Lancang Kuning, IndonesiaUniversitas Lancang Kuning, IndonesiaPower quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on the IEEE 1159-1995 standard, voltage sag is a decrease in RMS voltage with duration of 0.5 cycle to 1 minute. Sag voltage that occurs can have an effect on electronic equipment and other problems that often arise in the industrial environment. Therefore, a short circuit fault analysis was conducted to determine the voltage sag based on the type of fault in the sub system in Central Sumatera. Short circuit fault analysis is done using Powerworld Simulator 7.0 Students Edition. This study is intended to determine the sag voltage when there is a short circuit fault. The biggest voltage sag occurs when a short circuit fault of single phase to ground at 75% fault location and the smallest voltage sag when the three-phase short circuit of 0.7 fault location.https://ijeepse.id/journal/index.php/ijeepse/article/view/10power qualityshort circuitvoltage sag
spellingShingle Hamzah Eteruddin
Hendry Hendry
Atmam Atmam
Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
International Journal of Electrical, Energy and Power System Engineering
power quality
short circuit
voltage sag
title Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
title_full Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
title_fullStr Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
title_full_unstemmed Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
title_short Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
title_sort analysis of voltage sag due to short circuit on the sub system in central sumatera
topic power quality
short circuit
voltage sag
url https://ijeepse.id/journal/index.php/ijeepse/article/view/10
work_keys_str_mv AT hamzaheteruddin analysisofvoltagesagduetoshortcircuitonthesubsystemincentralsumatera
AT hendryhendry analysisofvoltagesagduetoshortcircuitonthesubsystemincentralsumatera
AT atmamatmam analysisofvoltagesagduetoshortcircuitonthesubsystemincentralsumatera