Comparison of local pulse wave velocity values acquired with EMFi sensor
The purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Durat...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Finnish Social and Health Informatics Association
2012-06-01
|
Series: | Finnish Journal of eHealth and eWelfare |
Subjects: | |
Online Access: | https://journal.fi/finjehew/article/view/6551 |
_version_ | 1818982513957142528 |
---|---|
author | Jarmo Alametsä Ari Palomäki |
author_facet | Jarmo Alametsä Ari Palomäki |
author_sort | Jarmo Alametsä |
collection | DOAJ |
description | The purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Duration of the signal components (pulse transit time; PTT) from the foot point and from the peak of the ankle and radial pulse signals according to R wave of the ECG were studied. PWV parameters between left and right wrist and respectively between left and right ankle were compared with Bland-Altman (BA) plots and with Pearson correlation in order to study, whether foot point or peak point from the ankle and radial pulse give consistent information about vascular elasticity in the form of PWV.
Results show that elastic information in the form of PWV is obtainable from the ankle and radial pulse signals having variation which depends from the detected site of the pulse signal. Little more variation was seen in the PWV and Pearson correlation values obtained from the foot point of the signal utilizing PTT with a minimum method. As the differences between the obtained results were relatively small, both locations are at least suitable in PWV determination giving consistent information about vascular elasticity. The variation in the form of the pulse signal due to local elasticity changes may challenge accurate point detection in PWV studies. |
first_indexed | 2024-12-20T17:48:25Z |
format | Article |
id | doaj.art-73250c72871e41ed9e5b501863f27940 |
institution | Directory Open Access Journal |
issn | 1798-0798 |
language | English |
last_indexed | 2024-12-20T17:48:25Z |
publishDate | 2012-06-01 |
publisher | Finnish Social and Health Informatics Association |
record_format | Article |
series | Finnish Journal of eHealth and eWelfare |
spelling | doaj.art-73250c72871e41ed9e5b501863f279402022-12-21T19:30:54ZengFinnish Social and Health Informatics AssociationFinnish Journal of eHealth and eWelfare1798-07982012-06-0142Comparison of local pulse wave velocity values acquired with EMFi sensorJarmo Alametsä0Ari Palomäki1Tampere University of Technology, TampereKanta-Häme Central Hospital, HämeenlinnaThe purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Duration of the signal components (pulse transit time; PTT) from the foot point and from the peak of the ankle and radial pulse signals according to R wave of the ECG were studied. PWV parameters between left and right wrist and respectively between left and right ankle were compared with Bland-Altman (BA) plots and with Pearson correlation in order to study, whether foot point or peak point from the ankle and radial pulse give consistent information about vascular elasticity in the form of PWV. Results show that elastic information in the form of PWV is obtainable from the ankle and radial pulse signals having variation which depends from the detected site of the pulse signal. Little more variation was seen in the PWV and Pearson correlation values obtained from the foot point of the signal utilizing PTT with a minimum method. As the differences between the obtained results were relatively small, both locations are at least suitable in PWV determination giving consistent information about vascular elasticity. The variation in the form of the pulse signal due to local elasticity changes may challenge accurate point detection in PWV studies.https://journal.fi/finjehew/article/view/6551EMFradial and ankle pulse signals |
spellingShingle | Jarmo Alametsä Ari Palomäki Comparison of local pulse wave velocity values acquired with EMFi sensor Finnish Journal of eHealth and eWelfare EMF radial and ankle pulse signals |
title | Comparison of local pulse wave velocity values acquired with EMFi sensor |
title_full | Comparison of local pulse wave velocity values acquired with EMFi sensor |
title_fullStr | Comparison of local pulse wave velocity values acquired with EMFi sensor |
title_full_unstemmed | Comparison of local pulse wave velocity values acquired with EMFi sensor |
title_short | Comparison of local pulse wave velocity values acquired with EMFi sensor |
title_sort | comparison of local pulse wave velocity values acquired with emfi sensor |
topic | EMF radial and ankle pulse signals |
url | https://journal.fi/finjehew/article/view/6551 |
work_keys_str_mv | AT jarmoalametsa comparisonoflocalpulsewavevelocityvaluesacquiredwithemfisensor AT aripalomaki comparisonoflocalpulsewavevelocityvaluesacquiredwithemfisensor |