Comparison of local pulse wave velocity values acquired with EMFi sensor

The purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Durat...

Full description

Bibliographic Details
Main Authors: Jarmo Alametsä, Ari Palomäki
Format: Article
Language:English
Published: Finnish Social and Health Informatics Association 2012-06-01
Series:Finnish Journal of eHealth and eWelfare
Subjects:
Online Access:https://journal.fi/finjehew/article/view/6551
_version_ 1818982513957142528
author Jarmo Alametsä
Ari Palomäki
author_facet Jarmo Alametsä
Ari Palomäki
author_sort Jarmo Alametsä
collection DOAJ
description The purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Duration of the signal components (pulse transit time; PTT) from the foot point and from the peak of the ankle and radial pulse signals according to R wave of the ECG were studied. PWV parameters between left and right wrist and respectively between left and right ankle were compared with Bland-Altman (BA) plots and with Pearson correlation in order to study, whether foot point or peak point from the ankle and radial pulse give consistent information about vascular elasticity in the form of PWV. Results show that elastic information in the form of PWV is obtainable from the ankle and radial pulse signals having variation which depends from the detected site of the pulse signal. Little more variation was seen in the PWV and Pearson correlation values obtained from the foot point of the signal utilizing PTT with a minimum method. As the differences between the obtained results were relatively small, both locations are at least suitable in PWV determination giving consistent information about vascular elasticity. The variation in the form of the pulse signal due to local elasticity changes may challenge accurate point detection in PWV studies.
first_indexed 2024-12-20T17:48:25Z
format Article
id doaj.art-73250c72871e41ed9e5b501863f27940
institution Directory Open Access Journal
issn 1798-0798
language English
last_indexed 2024-12-20T17:48:25Z
publishDate 2012-06-01
publisher Finnish Social and Health Informatics Association
record_format Article
series Finnish Journal of eHealth and eWelfare
spelling doaj.art-73250c72871e41ed9e5b501863f279402022-12-21T19:30:54ZengFinnish Social and Health Informatics AssociationFinnish Journal of eHealth and eWelfare1798-07982012-06-0142Comparison of local pulse wave velocity values acquired with EMFi sensorJarmo Alametsä0Ari Palomäki1Tampere University of Technology, TampereKanta-Häme Central Hospital, HämeenlinnaThe purpose of this work is to show the potential of Electromechanical Film (EMFi) sensor in local vascular elasticity studies via pulse wave velocity (PWV) obtained from limbs and radial arteries. ECG and pulse signals from the limbs were recorded from 48 working aged men in sitting position. Duration of the signal components (pulse transit time; PTT) from the foot point and from the peak of the ankle and radial pulse signals according to R wave of the ECG were studied. PWV parameters between left and right wrist and respectively between left and right ankle were compared with Bland-Altman (BA) plots and with Pearson correlation in order to study, whether foot point or peak point from the ankle and radial pulse give consistent information about vascular elasticity in the form of PWV. Results show that elastic information in the form of PWV is obtainable from the ankle and radial pulse signals having variation which depends from the detected site of the pulse signal. Little more variation was seen in the PWV and Pearson correlation values obtained from the foot point of the signal utilizing PTT with a minimum method. As the differences between the obtained results were relatively small, both locations are at least suitable in PWV determination giving consistent information about vascular elasticity. The variation in the form of the pulse signal due to local elasticity changes may challenge accurate point detection in PWV studies.https://journal.fi/finjehew/article/view/6551EMFradial and ankle pulse signals
spellingShingle Jarmo Alametsä
Ari Palomäki
Comparison of local pulse wave velocity values acquired with EMFi sensor
Finnish Journal of eHealth and eWelfare
EMF
radial and ankle pulse signals
title Comparison of local pulse wave velocity values acquired with EMFi sensor
title_full Comparison of local pulse wave velocity values acquired with EMFi sensor
title_fullStr Comparison of local pulse wave velocity values acquired with EMFi sensor
title_full_unstemmed Comparison of local pulse wave velocity values acquired with EMFi sensor
title_short Comparison of local pulse wave velocity values acquired with EMFi sensor
title_sort comparison of local pulse wave velocity values acquired with emfi sensor
topic EMF
radial and ankle pulse signals
url https://journal.fi/finjehew/article/view/6551
work_keys_str_mv AT jarmoalametsa comparisonoflocalpulsewavevelocityvaluesacquiredwithemfisensor
AT aripalomaki comparisonoflocalpulsewavevelocityvaluesacquiredwithemfisensor