Visual and subjective outcomes following trifocal intraocular lens implantation in Iranian cataractous patients

BACKGROUND: The aim of this study was to evaluate visual and refractive outcomes and quality of vision after implantation of the AT LISA tri 839MP intraocular lens (IOL). PATIENTS AND METHODS: This interventional clinical trial comprised 46 cataractous eyes of patients who underwent phacoemulsificat...

Full description

Bibliographic Details
Main Authors: Farhad Nejat, Shiva Pirhadi, Hossein Aghamollaei, Mostafa Naderi, Mohamadmahdi Najafi Ghodsi, Reza Gharebaghi, Khosrow Jadidi
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2020-01-01
Series:Oman Journal of Ophthalmology
Subjects:
Online Access:http://www.ojoonline.org/article.asp?issn=0974-620X;year=2020;volume=13;issue=2;spage=63;epage=69;aulast=Nejat
Description
Summary:BACKGROUND: The aim of this study was to evaluate visual and refractive outcomes and quality of vision after implantation of the AT LISA tri 839MP intraocular lens (IOL). PATIENTS AND METHODS: This interventional clinical trial comprised 46 cataractous eyes of patients who underwent phacoemulsification with IOL implantation (mean age of 58.08 ± 11.01 years; range: 36–76 years old). Spherical equivalent (SE), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), corrected intermediate visual acuity (CIVA), uncorrected near visual acuity (UNVA), and corrected near visual acuity (CNVA) were measured 1, 3, and 6 months after surgery. Contrast sensitivity (CS) was measured at 6 months. Subjective quality of vision and presence of dysphotopsia by a short questionnaire were evaluated postoperatively. RESULTS: At 6 months, the mean visual acuity was 0.08 ± 0.11, 0.03 ± 0.08, 0.07 ± 0.09, 0.02 ± 0.08, 0.05 ± 0.09, and 0.02 ± 0.08 LogMAR for UDVA, CDVA, UIVA, CIVA, UNVA, and CNVA, respectively. The mean values of SE were − 0.4728 ± 0.32D. These variables improved over time, yet significant changes were detected in UDVA (P = 0.009) and SE (P = 0.0001). The mean CS value was 1.74 ± 0.08. The mean scores (0% = no symptoms; 100% = strong symptoms/unable to perform activities) for glare and halos were 7.07 ± 0.22% and 8.70 ± 0.23%, respectively. These items were reduced over time. Patients' level of satisfaction mean score for performing activities was 96.66%. CONCLUSIONS: The AT LISA tri 839MP IOL provides excellent uncorrected distance, intermediate and near vision, and CS. This IOL showed a minimal level of photic phenomena and a high level of patient satisfaction.
ISSN:0974-620X