Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser

Dosing of dry concentrated feed to dairy cows is one of the most important tasks in the field of livestock mechanization. Devices that carry out volume dosing are more reliable and easier to be manufactured. Volumetric dispensers also include a spiral-screw dispenser – a special case of a screw disp...

Full description

Bibliographic Details
Main Author: Lyalin Evgeny
Format: Article
Language:English
Published: EDP Sciences 2022-01-01
Series:BIO Web of Conferences
Online Access:https://www.bio-conferences.org/articles/bioconf/pdf/2022/11/bioconf_fies2022_00036.pdf
_version_ 1798001757403480064
author Lyalin Evgeny
author_facet Lyalin Evgeny
author_sort Lyalin Evgeny
collection DOAJ
description Dosing of dry concentrated feed to dairy cows is one of the most important tasks in the field of livestock mechanization. Devices that carry out volume dosing are more reliable and easier to be manufactured. Volumetric dispensers also include a spiral-screw dispenser – a special case of a screw dispenser. It is proposed to study the working process of the spiral-screw dispenser, namely the influence of a stopping angle of the last turn of the transporting spiral at the end of the discharge hole of the cylindrical casing. The paper indicates the method of determining and the value of the physical and mechanical properties of granulated feed. A laboratory installation on which it is possible to change the angle of installation of the spiral on the drive shaft is described. To study the effect of the stopping angle of the last turn of the transporting spiral on the accuracy of the formation of the feed portion, spirals with a diameter of 49, 73, 97 mm with different steps of 0.75, 1 and 1.25 of the diameter values were used. As a result of the experiments, it was revealed that the lowest coefficient of variation is 0.56 – 17.50%. And, accordingly, the greatest dosing accuracy is obtained when the last turn of the spiral stops at the position of 0°. That is, when the turn stops at the edge of the discharge neck in its lower part and this is typical for all sizes of spirals that were used.
first_indexed 2024-04-11T11:41:13Z
format Article
id doaj.art-73bf89651420481691d703be8f09407f
institution Directory Open Access Journal
issn 2117-4458
language English
last_indexed 2024-04-11T11:41:13Z
publishDate 2022-01-01
publisher EDP Sciences
record_format Article
series BIO Web of Conferences
spelling doaj.art-73bf89651420481691d703be8f09407f2022-12-22T04:25:50ZengEDP SciencesBIO Web of Conferences2117-44582022-01-01520003610.1051/bioconf/20225200036bioconf_fies2022_00036Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenserLyalin Evgeny0Perm State Agro-Technological University named after Academician D.N. PryanishnikovDosing of dry concentrated feed to dairy cows is one of the most important tasks in the field of livestock mechanization. Devices that carry out volume dosing are more reliable and easier to be manufactured. Volumetric dispensers also include a spiral-screw dispenser – a special case of a screw dispenser. It is proposed to study the working process of the spiral-screw dispenser, namely the influence of a stopping angle of the last turn of the transporting spiral at the end of the discharge hole of the cylindrical casing. The paper indicates the method of determining and the value of the physical and mechanical properties of granulated feed. A laboratory installation on which it is possible to change the angle of installation of the spiral on the drive shaft is described. To study the effect of the stopping angle of the last turn of the transporting spiral on the accuracy of the formation of the feed portion, spirals with a diameter of 49, 73, 97 mm with different steps of 0.75, 1 and 1.25 of the diameter values were used. As a result of the experiments, it was revealed that the lowest coefficient of variation is 0.56 – 17.50%. And, accordingly, the greatest dosing accuracy is obtained when the last turn of the spiral stops at the position of 0°. That is, when the turn stops at the edge of the discharge neck in its lower part and this is typical for all sizes of spirals that were used.https://www.bio-conferences.org/articles/bioconf/pdf/2022/11/bioconf_fies2022_00036.pdf
spellingShingle Lyalin Evgeny
Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
BIO Web of Conferences
title Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
title_full Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
title_fullStr Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
title_full_unstemmed Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
title_short Influence of a stopping angle of a spiral coil on the operation of a spiral-screw dispenser
title_sort influence of a stopping angle of a spiral coil on the operation of a spiral screw dispenser
url https://www.bio-conferences.org/articles/bioconf/pdf/2022/11/bioconf_fies2022_00036.pdf
work_keys_str_mv AT lyalinevgeny influenceofastoppingangleofaspiralcoilontheoperationofaspiralscrewdispenser