Impedance-Based Short Circuit—Short Circuit Fault Location Method in Coaxial Cables
The paper presents the results of the assessment and verification of a non-destructive method of fault location in coaxial cables with a local weakening of insulation. The essence of the method is to measure the input impedance of the cable in a short circuit at both ends and, based on obtained valu...
Main Authors: | Aneta Bugajska, Tomasz Desaniuk |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2023-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/10266351/ |
Similar Items
-
INFLUENCE OF CONSTRUCTIVE AND TECHNOLOGICAL DEFECTS ON COAXIAL RADIO-FREQUENCY CABLE IMPEDANCE
by: G.V. Bezprozvannych, et al.
Published: (2013-04-01) -
Circuit models of Lossy Coaxial Shielded cables to Analyze Radiated and Conducted Susceptibilities with unmatched line loads
by: M. SAIH, et al. -
Diagnosis and Location of Power Cable Faults Based on Characteristic Frequencies of Impedance Spectroscopy
by: Gen Li, et al.
Published: (2022-08-01) -
Improvement of Pulse Shape by Reducing Ripple Using Coaxial Cable
by: Yin Yin Mya
Published: (2023-09-01) -
Coaxial cables for wired distribution systems
by: 8096 British Standards Institution