Measurements of knee rotation-reliability of an external device in vivo

<p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of ske...

Full description

Bibliographic Details
Main Authors: Almquist Per O, Ekdahl Charlotte, Isberg Per-Erik, Fridén Thomas
Format: Article
Language:English
Published: BMC 2011-12-01
Series:BMC Musculoskeletal Disorders
Online Access:http://www.biomedcentral.com/1471-2474/12/291
_version_ 1818918660046061568
author Almquist Per O
Ekdahl Charlotte
Isberg Per-Erik
Fridén Thomas
author_facet Almquist Per O
Ekdahl Charlotte
Isberg Per-Erik
Fridén Thomas
author_sort Almquist Per O
collection DOAJ
description <p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device.</p> <p>Method</p> <p>The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient <sub>2,1 </sub>(ICC <sub>2,1</sub>), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests.</p> <p>Result</p> <p>ICC<sub>2,1 </sub>ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque.</p> <p>Conclusion</p> <p>The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.</p>
first_indexed 2024-12-20T00:53:29Z
format Article
id doaj.art-745def018ce34d11b1ebecbe2308f82b
institution Directory Open Access Journal
issn 1471-2474
language English
last_indexed 2024-12-20T00:53:29Z
publishDate 2011-12-01
publisher BMC
record_format Article
series BMC Musculoskeletal Disorders
spelling doaj.art-745def018ce34d11b1ebecbe2308f82b2022-12-21T19:59:10ZengBMCBMC Musculoskeletal Disorders1471-24742011-12-0112129110.1186/1471-2474-12-291Measurements of knee rotation-reliability of an external device in vivoAlmquist Per OEkdahl CharlotteIsberg Per-ErikFridén Thomas<p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device.</p> <p>Method</p> <p>The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient <sub>2,1 </sub>(ICC <sub>2,1</sub>), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests.</p> <p>Result</p> <p>ICC<sub>2,1 </sub>ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque.</p> <p>Conclusion</p> <p>The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.</p>http://www.biomedcentral.com/1471-2474/12/291
spellingShingle Almquist Per O
Ekdahl Charlotte
Isberg Per-Erik
Fridén Thomas
Measurements of knee rotation-reliability of an external device in vivo
BMC Musculoskeletal Disorders
title Measurements of knee rotation-reliability of an external device in vivo
title_full Measurements of knee rotation-reliability of an external device in vivo
title_fullStr Measurements of knee rotation-reliability of an external device in vivo
title_full_unstemmed Measurements of knee rotation-reliability of an external device in vivo
title_short Measurements of knee rotation-reliability of an external device in vivo
title_sort measurements of knee rotation reliability of an external device in vivo
url http://www.biomedcentral.com/1471-2474/12/291
work_keys_str_mv AT almquistpero measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT ekdahlcharlotte measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT isbergpererik measurementsofkneerotationreliabilityofanexternaldeviceinvivo
AT fridenthomas measurementsofkneerotationreliabilityofanexternaldeviceinvivo