Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance

This paper presents a new triple phase shift (TPS) closed-loop control scheme of a dual active bridge (DAB) LCC resonant DC/DC converter to improve wireless charging power transfer efficiency. The primary side inverter phase shift angle regulates the battery charging current/voltage. The secondary s...

Full description

Bibliographic Details
Main Authors: Yanni Cheong, Shuyu Cao, Ramasamy Thaiyal Naayagi, Szesing Lee
Format: Article
Language:English
Published: MDPI AG 2022-11-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/22/11871
_version_ 1797465920144146432
author Yanni Cheong
Shuyu Cao
Ramasamy Thaiyal Naayagi
Szesing Lee
author_facet Yanni Cheong
Shuyu Cao
Ramasamy Thaiyal Naayagi
Szesing Lee
author_sort Yanni Cheong
collection DOAJ
description This paper presents a new triple phase shift (TPS) closed-loop control scheme of a dual active bridge (DAB) LCC resonant DC/DC converter to improve wireless charging power transfer efficiency. The primary side inverter phase shift angle regulates the battery charging current/voltage. The secondary side rectifier phase shift angle regulates the rectifier AC load resistance to match its optimized setting. The inverter-to-rectifier phase shift angle is set to achieve unity power factor operation of the DAB rectifier and inverter. The mathematical formulation of the TPS shift control is given for each phase shift angle. The analytical calculation, circuit simulation, and experimental test are carried out in a power scaled-down DAB LCC resonant wireless charging converter laboratory hardware setup to validate the proposed TPS close-loop control scheme. The PLECS circuit simulation shows that DAB LCC resonant SiC MOSFET operates at zero-voltage-switching (ZVS) with a unity power factor in emulated constant current (CC) mode battery charging. In constant voltage (CV) mode operation, one inverter/rectifier Leg does not operate at ZVS switching when Sic MOSFET is switched on near zero current. The experimental results show that the efficiency is greatly improved for CV mode charging with large DC load resistance connected if rectifier AC load resistance matching control is enabled. The measured efficiency matches well with the analytical calculation. The estimated efficiency improvement will be much more significant for EV applications in the kW power range with greater winding loss. The challenges and possible solutions to implement TPS PWM modulation in two separate inverter and rectifier control hardware are explained for future TPS control algorithm development in practical wireless charging products.
first_indexed 2024-03-09T18:29:23Z
format Article
id doaj.art-749b329f9a7a44b58635522dd6936363
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-09T18:29:23Z
publishDate 2022-11-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-749b329f9a7a44b58635522dd69363632023-11-24T07:42:16ZengMDPI AGApplied Sciences2076-34172022-11-0112221187110.3390/app122211871Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load ResistanceYanni Cheong0Shuyu Cao1Ramasamy Thaiyal Naayagi2Szesing Lee3Singapore Institute of Technology, Electrical Power Engineering, 10 Dover Drive, Singapore 138683, SingaporeSingapore Institute of Technology, Electrical Power Engineering, 10 Dover Drive, Singapore 138683, SingaporeSchool of Electrical and Electronic Engineering, Newcastle University International, SIT@NYP, 172A Ang Mo Kio Avenue 8 #05-01, Singapore 567739, SingaporeSchool of Electrical and Electronic Engineering, Newcastle University International, SIT@NYP, 172A Ang Mo Kio Avenue 8 #05-01, Singapore 567739, SingaporeThis paper presents a new triple phase shift (TPS) closed-loop control scheme of a dual active bridge (DAB) LCC resonant DC/DC converter to improve wireless charging power transfer efficiency. The primary side inverter phase shift angle regulates the battery charging current/voltage. The secondary side rectifier phase shift angle regulates the rectifier AC load resistance to match its optimized setting. The inverter-to-rectifier phase shift angle is set to achieve unity power factor operation of the DAB rectifier and inverter. The mathematical formulation of the TPS shift control is given for each phase shift angle. The analytical calculation, circuit simulation, and experimental test are carried out in a power scaled-down DAB LCC resonant wireless charging converter laboratory hardware setup to validate the proposed TPS close-loop control scheme. The PLECS circuit simulation shows that DAB LCC resonant SiC MOSFET operates at zero-voltage-switching (ZVS) with a unity power factor in emulated constant current (CC) mode battery charging. In constant voltage (CV) mode operation, one inverter/rectifier Leg does not operate at ZVS switching when Sic MOSFET is switched on near zero current. The experimental results show that the efficiency is greatly improved for CV mode charging with large DC load resistance connected if rectifier AC load resistance matching control is enabled. The measured efficiency matches well with the analytical calculation. The estimated efficiency improvement will be much more significant for EV applications in the kW power range with greater winding loss. The challenges and possible solutions to implement TPS PWM modulation in two separate inverter and rectifier control hardware are explained for future TPS control algorithm development in practical wireless charging products.https://www.mdpi.com/2076-3417/12/22/11871wireless chargingdual active bridge (DAB)DC/DC converterLCC resonant circuittriple phase shift (TPS)constant current (CC) battery charging
spellingShingle Yanni Cheong
Shuyu Cao
Ramasamy Thaiyal Naayagi
Szesing Lee
Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
Applied Sciences
wireless charging
dual active bridge (DAB)
DC/DC converter
LCC resonant circuit
triple phase shift (TPS)
constant current (CC) battery charging
title Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
title_full Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
title_fullStr Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
title_full_unstemmed Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
title_short Triple Phase Shift Control of Wireless Charging DAB LCC Resonant Converter for Unity Power Factor Operation with Optimized Rectifier AC Load Resistance
title_sort triple phase shift control of wireless charging dab lcc resonant converter for unity power factor operation with optimized rectifier ac load resistance
topic wireless charging
dual active bridge (DAB)
DC/DC converter
LCC resonant circuit
triple phase shift (TPS)
constant current (CC) battery charging
url https://www.mdpi.com/2076-3417/12/22/11871
work_keys_str_mv AT yannicheong triplephaseshiftcontrolofwirelesschargingdablccresonantconverterforunitypowerfactoroperationwithoptimizedrectifieracloadresistance
AT shuyucao triplephaseshiftcontrolofwirelesschargingdablccresonantconverterforunitypowerfactoroperationwithoptimizedrectifieracloadresistance
AT ramasamythaiyalnaayagi triplephaseshiftcontrolofwirelesschargingdablccresonantconverterforunitypowerfactoroperationwithoptimizedrectifieracloadresistance
AT szesinglee triplephaseshiftcontrolofwirelesschargingdablccresonantconverterforunitypowerfactoroperationwithoptimizedrectifieracloadresistance