Liquid scintillation counting at the limit of detection in biogeosciences

Liquid scintillation is widely used to quantify the activity of radioisotopes. We present an overview of the technique and its application to biogeosciences, particularly for turnover rate measurements. Microbial communities and their metabolism are notoriously difficult to analyze in low energy env...

Full description

Bibliographic Details
Main Authors: Florian Schubert, Jens Kallmeyer
Format: Article
Language:English
Published: Frontiers Media S.A. 2023-07-01
Series:Frontiers in Microbiology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fmicb.2023.1194848/full
_version_ 1827906055695237120
author Florian Schubert
Jens Kallmeyer
author_facet Florian Schubert
Jens Kallmeyer
author_sort Florian Schubert
collection DOAJ
description Liquid scintillation is widely used to quantify the activity of radioisotopes. We present an overview of the technique and its application to biogeosciences, particularly for turnover rate measurements. Microbial communities and their metabolism are notoriously difficult to analyze in low energy environments as biomass is exceedingly sparse and turnover rates low. Highly sensitive methods, such as liquid scintillation counting, are required to investigate low metabolic rates and conclusively differentiate them from the background noise of the respective analyzer. We conducted a series of experiments to explore the effects of luminescence, measurement time and temperature on scintillation measurements. Luminescence, the spontaneous emission of photons, disproportionally affects samples within the first few hours after sample preparation and can be minimized by following simple guidelines. Short measurement times will negatively affect liquid scintillation analysis or if background noise makes up a significant proportion of the detected events. Measurement temperature affected liquid scintillation analysis only when the temperature during the measurement reached approximately 30°C or higher, i.e. the liquid scintillation analyzer was placed in an environment without temperature control, but not in cases where chemicals were stored at elevated temperatures prior to measurement. Basic understanding on the functionality of a liquid scintillation analyzer and simple precautions prior to the measurement can significantly lower the minimum detection limit and therefore allow for determination of low turnover rates previously lost in the background noise.
first_indexed 2024-03-13T00:51:19Z
format Article
id doaj.art-74a766518cb84085a36f310bc3a176b4
institution Directory Open Access Journal
issn 1664-302X
language English
last_indexed 2024-03-13T00:51:19Z
publishDate 2023-07-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Microbiology
spelling doaj.art-74a766518cb84085a36f310bc3a176b42023-07-07T13:56:34ZengFrontiers Media S.A.Frontiers in Microbiology1664-302X2023-07-011410.3389/fmicb.2023.11948481194848Liquid scintillation counting at the limit of detection in biogeosciencesFlorian SchubertJens KallmeyerLiquid scintillation is widely used to quantify the activity of radioisotopes. We present an overview of the technique and its application to biogeosciences, particularly for turnover rate measurements. Microbial communities and their metabolism are notoriously difficult to analyze in low energy environments as biomass is exceedingly sparse and turnover rates low. Highly sensitive methods, such as liquid scintillation counting, are required to investigate low metabolic rates and conclusively differentiate them from the background noise of the respective analyzer. We conducted a series of experiments to explore the effects of luminescence, measurement time and temperature on scintillation measurements. Luminescence, the spontaneous emission of photons, disproportionally affects samples within the first few hours after sample preparation and can be minimized by following simple guidelines. Short measurement times will negatively affect liquid scintillation analysis or if background noise makes up a significant proportion of the detected events. Measurement temperature affected liquid scintillation analysis only when the temperature during the measurement reached approximately 30°C or higher, i.e. the liquid scintillation analyzer was placed in an environment without temperature control, but not in cases where chemicals were stored at elevated temperatures prior to measurement. Basic understanding on the functionality of a liquid scintillation analyzer and simple precautions prior to the measurement can significantly lower the minimum detection limit and therefore allow for determination of low turnover rates previously lost in the background noise.https://www.frontiersin.org/articles/10.3389/fmicb.2023.1194848/fullbackground measurementsliquid scintillationminimum detection limitradioisotopesbiotic fringe
spellingShingle Florian Schubert
Jens Kallmeyer
Liquid scintillation counting at the limit of detection in biogeosciences
Frontiers in Microbiology
background measurements
liquid scintillation
minimum detection limit
radioisotopes
biotic fringe
title Liquid scintillation counting at the limit of detection in biogeosciences
title_full Liquid scintillation counting at the limit of detection in biogeosciences
title_fullStr Liquid scintillation counting at the limit of detection in biogeosciences
title_full_unstemmed Liquid scintillation counting at the limit of detection in biogeosciences
title_short Liquid scintillation counting at the limit of detection in biogeosciences
title_sort liquid scintillation counting at the limit of detection in biogeosciences
topic background measurements
liquid scintillation
minimum detection limit
radioisotopes
biotic fringe
url https://www.frontiersin.org/articles/10.3389/fmicb.2023.1194848/full
work_keys_str_mv AT florianschubert liquidscintillationcountingatthelimitofdetectioninbiogeosciences
AT jenskallmeyer liquidscintillationcountingatthelimitofdetectioninbiogeosciences