Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension

Aims and objectives: This research aims to establish the usefulness of timed over- night (8 hours) Urine Albumin(microalbumin) Excretion (UAE), in monitoring therapy in Nigerian patients with benign essential hypertension. Subjects and Methods: The study population comprised 40 normotensives/con-...

Full description

Bibliographic Details
Main Authors: I O Oluwatowoju, JNA Ajuluchukwu, O A Afonja
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2014-01-01
Series:Nigerian Postgraduate Medical Journal
Subjects:
Online Access:http://www.npmj.org/article.asp?issn=1117-1936;year=2014;volume=21;issue=2;spage=177;epage=180;aulast=Oluwatowoju
_version_ 1818492549090770944
author I O Oluwatowoju
JNA Ajuluchukwu
O A Afonja
author_facet I O Oluwatowoju
JNA Ajuluchukwu
O A Afonja
author_sort I O Oluwatowoju
collection DOAJ
description Aims and objectives: This research aims to establish the usefulness of timed over- night (8 hours) Urine Albumin(microalbumin) Excretion (UAE), in monitoring therapy in Nigerian patients with benign essential hypertension. Subjects and Methods: The study population comprised 40 normotensives/con- trols, (23 males and 17 females) aged between 20-70 years, with a mean blood pressure 116/75mmHg, 30 well-controlled hypertensive patients, diastolic BP < 100mmHg or MAP (mean arterial pressure) = 110mmHg and 30 poorly con- trolled hypertensive patients, diastolic blood pressure > 100mmHg or MAP > 110mmHg. albumin(microalbumin) was determined on the 8 hours overnight urine samples by ELISA method using kit from Randox Laboratories Limited, N. Ireland Cat No. MA 1410. UAE was calculated from the urine albumin concentration, urine volume and collection time. The intra assay precision was determined by running 20 replicates of two kit controls in a single batch. The coefficient of variation was 6.6% at 10.70mg/L and 4.3% at 51.20mg/L. Results: The average UAE in the three groups were as follows: 12:22 +/- 4.65μg/ min, 21.50 +/- 10.5μg/min and 30.10 +/- 24.25 μg/min in the control, well con- trolled and poorly controlled groups respectively, 12.5% of normotensive sub- jects, 40% of well controlled and 56.7% of poorly controlled patients were found to have microalbuminuria. The UAE increased significantly with the severity of hypertension (r = 0.32, p<0.001 for control) r = 0.38, p<0.05 for controlled and r = 0.49 p<0.05 for poorly controlled. Conclusion:A timed overnight (8 hours) Urinary UAE is a preferred alternative to cumbersome 24 hours urine collection for monitoring response to treatment in Nigerian patients with benign essential hypertension.
first_indexed 2024-12-10T17:44:44Z
format Article
id doaj.art-7591bfc764504ed7bd4cb9d8501c3207
institution Directory Open Access Journal
issn 1117-1936
2468-6875
language English
last_indexed 2024-12-10T17:44:44Z
publishDate 2014-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Nigerian Postgraduate Medical Journal
spelling doaj.art-7591bfc764504ed7bd4cb9d8501c32072022-12-22T01:39:16ZengWolters Kluwer Medknow PublicationsNigerian Postgraduate Medical Journal1117-19362468-68752014-01-01212177180Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertensionI O OluwatowojuJNA AjuluchukwuO A AfonjaAims and objectives: This research aims to establish the usefulness of timed over- night (8 hours) Urine Albumin(microalbumin) Excretion (UAE), in monitoring therapy in Nigerian patients with benign essential hypertension. Subjects and Methods: The study population comprised 40 normotensives/con- trols, (23 males and 17 females) aged between 20-70 years, with a mean blood pressure 116/75mmHg, 30 well-controlled hypertensive patients, diastolic BP < 100mmHg or MAP (mean arterial pressure) = 110mmHg and 30 poorly con- trolled hypertensive patients, diastolic blood pressure > 100mmHg or MAP > 110mmHg. albumin(microalbumin) was determined on the 8 hours overnight urine samples by ELISA method using kit from Randox Laboratories Limited, N. Ireland Cat No. MA 1410. UAE was calculated from the urine albumin concentration, urine volume and collection time. The intra assay precision was determined by running 20 replicates of two kit controls in a single batch. The coefficient of variation was 6.6% at 10.70mg/L and 4.3% at 51.20mg/L. Results: The average UAE in the three groups were as follows: 12:22 +/- 4.65μg/ min, 21.50 +/- 10.5μg/min and 30.10 +/- 24.25 μg/min in the control, well con- trolled and poorly controlled groups respectively, 12.5% of normotensive sub- jects, 40% of well controlled and 56.7% of poorly controlled patients were found to have microalbuminuria. The UAE increased significantly with the severity of hypertension (r = 0.32, p<0.001 for control) r = 0.38, p<0.05 for controlled and r = 0.49 p<0.05 for poorly controlled. Conclusion:A timed overnight (8 hours) Urinary UAE is a preferred alternative to cumbersome 24 hours urine collection for monitoring response to treatment in Nigerian patients with benign essential hypertension.http://www.npmj.org/article.asp?issn=1117-1936;year=2014;volume=21;issue=2;spage=177;epage=180;aulast=Oluwatowojuurine albumin excretionessential hypertension
spellingShingle I O Oluwatowoju
JNA Ajuluchukwu
O A Afonja
Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
Nigerian Postgraduate Medical Journal
urine albumin excretion
essential hypertension
title Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
title_full Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
title_fullStr Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
title_full_unstemmed Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
title_short Clinical Usefulness of a timed overnight (8 hours) Urine Albumin (microalbumin) Excretion in monitor- ing treatment in benign essential hypertension
title_sort clinical usefulness of a timed overnight 8 hours urine albumin microalbumin excretion in monitor ing treatment in benign essential hypertension
topic urine albumin excretion
essential hypertension
url http://www.npmj.org/article.asp?issn=1117-1936;year=2014;volume=21;issue=2;spage=177;epage=180;aulast=Oluwatowoju
work_keys_str_mv AT iooluwatowoju clinicalusefulnessofatimedovernight8hoursurinealbuminmicroalbuminexcretioninmonitoringtreatmentinbenignessentialhypertension
AT jnaajuluchukwu clinicalusefulnessofatimedovernight8hoursurinealbuminmicroalbuminexcretioninmonitoringtreatmentinbenignessentialhypertension
AT oaafonja clinicalusefulnessofatimedovernight8hoursurinealbuminmicroalbuminexcretioninmonitoringtreatmentinbenignessentialhypertension