Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
Both conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-05-01
|
Series: | Journal of Personalized Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4426/13/5/832 |
_version_ | 1797599442440814592 |
---|---|
author | Noemie Drancourt Chantal Auduc Aymeric Mouget Jean Mouminoux Pascal Auroy Jean-Luc Veyrune Nada El Osta Emmanuel Nicolas |
author_facet | Noemie Drancourt Chantal Auduc Aymeric Mouget Jean Mouminoux Pascal Auroy Jean-Luc Veyrune Nada El Osta Emmanuel Nicolas |
author_sort | Noemie Drancourt |
collection | DOAJ |
description | Both conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study was to compare the trueness and precision of conventional and digital impressions obtained with four intra-oral scanners: Trios 4 from 3Shape<sup>®</sup>, Primescan from Dentsply Sirona<sup>®</sup>, CS3600 from Carestream<sup>®</sup> and i500 from Medit<sup>®</sup>. This study focused on the impression of an edentulous maxilla in which five implants were placed for implant-supported complete prosthesis. The digital models were superimposed on a digital reference model using dimensional control and metrology software. Angular and distance deviations from the digital reference model were calculated to assess trueness. Dispersion of the values around their mean for each impression was also calculated for precision. The mean distance deviation in absolute value and the direction of the distance deviation were smaller for conventional impressions (<i>p</i>-value < 0.001). The I-500 had the best results regarding angular measurements, followed by Trios 4 and CS3600 (<i>p</i> < 0.001). The conventional and I-500 digital impressions showed the lowest dispersion of values around the mean (<i>p</i>-value < 0.001). Within the limitations of our study, our results revealed that the conventional impression was more accurate than the digital impression, but further clinical studies are needed to confirm these findings. |
first_indexed | 2024-03-11T03:35:32Z |
format | Article |
id | doaj.art-75a79622881d4338bd737c260b7ac27e |
institution | Directory Open Access Journal |
issn | 2075-4426 |
language | English |
last_indexed | 2024-03-11T03:35:32Z |
publishDate | 2023-05-01 |
publisher | MDPI AG |
record_format | Article |
series | Journal of Personalized Medicine |
spelling | doaj.art-75a79622881d4338bd737c260b7ac27e2023-11-18T02:04:46ZengMDPI AGJournal of Personalized Medicine2075-44262023-05-0113583210.3390/jpm13050832Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro StudyNoemie Drancourt0Chantal Auduc1Aymeric Mouget2Jean Mouminoux3Pascal Auroy4Jean-Luc Veyrune5Nada El Osta6Emmanuel Nicolas7UFR d’Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, FranceCHU Clermont-Ferrand, Service d’Odontologie, F-63003 Clermont-Ferrand, FranceCHU Clermont-Ferrand, Service d’Odontologie, F-63003 Clermont-Ferrand, FranceCHU Clermont-Ferrand, Service d’Odontologie, F-63003 Clermont-Ferrand, FranceUFR d’Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, FranceUFR d’Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, FranceUFR d’Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, FranceUFR d’Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, FranceBoth conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study was to compare the trueness and precision of conventional and digital impressions obtained with four intra-oral scanners: Trios 4 from 3Shape<sup>®</sup>, Primescan from Dentsply Sirona<sup>®</sup>, CS3600 from Carestream<sup>®</sup> and i500 from Medit<sup>®</sup>. This study focused on the impression of an edentulous maxilla in which five implants were placed for implant-supported complete prosthesis. The digital models were superimposed on a digital reference model using dimensional control and metrology software. Angular and distance deviations from the digital reference model were calculated to assess trueness. Dispersion of the values around their mean for each impression was also calculated for precision. The mean distance deviation in absolute value and the direction of the distance deviation were smaller for conventional impressions (<i>p</i>-value < 0.001). The I-500 had the best results regarding angular measurements, followed by Trios 4 and CS3600 (<i>p</i> < 0.001). The conventional and I-500 digital impressions showed the lowest dispersion of values around the mean (<i>p</i>-value < 0.001). Within the limitations of our study, our results revealed that the conventional impression was more accurate than the digital impression, but further clinical studies are needed to confirm these findings.https://www.mdpi.com/2075-4426/13/5/832digital scanningconventional impressionaccuracyangular deviationsdistance deviationsimplant-supported full prosthesis |
spellingShingle | Noemie Drancourt Chantal Auduc Aymeric Mouget Jean Mouminoux Pascal Auroy Jean-Luc Veyrune Nada El Osta Emmanuel Nicolas Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study Journal of Personalized Medicine digital scanning conventional impression accuracy angular deviations distance deviations implant-supported full prosthesis |
title | Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study |
title_full | Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study |
title_fullStr | Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study |
title_full_unstemmed | Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study |
title_short | Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study |
title_sort | accuracy of conventional and digital impressions for full arch implant supported prostheses an in vitro study |
topic | digital scanning conventional impression accuracy angular deviations distance deviations implant-supported full prosthesis |
url | https://www.mdpi.com/2075-4426/13/5/832 |
work_keys_str_mv | AT noemiedrancourt accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT chantalauduc accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT aymericmouget accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT jeanmouminoux accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT pascalauroy accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT jeanlucveyrune accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT nadaelosta accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy AT emmanuelnicolas accuracyofconventionalanddigitalimpressionsforfullarchimplantsupportedprosthesesaninvitrostudy |