Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan

Introduction and Objective: Nuclear renal scan is currently the gold standard imaging study to determine differential renal function. We propose helical CT as single modality for both the anatomical and functional evaluation of kidney with impaired function. In the present study renal parenchymal vo...

Full description

Bibliographic Details
Main Authors: Debanga Sarma, Sasanka K Barua, T P Rajeev, Saumar J Baruah
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2012-01-01
Series:Indian Journal of Urology
Subjects:
Online Access:http://www.indianjurol.com/article.asp?issn=0970-1591;year=2012;volume=28;issue=4;spage=414;epage=417;aulast=Sarma
_version_ 1819102021041520640
author Debanga Sarma
Sasanka K Barua
T P Rajeev
Saumar J Baruah
author_facet Debanga Sarma
Sasanka K Barua
T P Rajeev
Saumar J Baruah
author_sort Debanga Sarma
collection DOAJ
description Introduction and Objective: Nuclear renal scan is currently the gold standard imaging study to determine differential renal function. We propose helical CT as single modality for both the anatomical and functional evaluation of kidney with impaired function. In the present study renal parenchymal volume is measured and percent total renal volume is used as a surrogate marker for differential renal function. The objective of this study is to correlate between differential renal function estimation using CT-based renal parenchymal volume measurement with differential renal function estimation using 99m TC - DTPA renal scan. Materials and Methods: Twenty-one patients with unilateral obstructive uropathy were enrolled in this prospective comparative study. They were subjected to 99m Tc - DTPA renal scan and 64 slice helical CT scan which estimates the renal volume depending on the reconstruction of arterial phase images followed by volume rendering and percent renal volume was calculated. Percent renal volume was correlated with percent renal function, as determined by nuclear renal scan using Pearson coefficient. Results and Observation: A strong correlation is observed between percent renal volume and percent renal function in obstructed units (r = 0.828, P < 0.001) as well as in nonobstructed units (r = 0.827, P < 0.001). Conclusion: There is a strong correlation between percent renal volume determined by CT scan and percent renal function determined by 99m TC - DTPA renal scan both in obstructed and in normal units. CT-based percent renal volume can be used as a single radiological tests for both functional and anatomical assessment of impaired renal units.
first_indexed 2024-12-22T01:27:56Z
format Article
id doaj.art-75cefeaae95c4825ad7adcbe7c806f89
institution Directory Open Access Journal
issn 0970-1591
1998-3824
language English
last_indexed 2024-12-22T01:27:56Z
publishDate 2012-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Urology
spelling doaj.art-75cefeaae95c4825ad7adcbe7c806f892022-12-21T18:43:33ZengWolters Kluwer Medknow PublicationsIndian Journal of Urology0970-15911998-38242012-01-0128441441710.4103/0970-1591.105753Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scanDebanga SarmaSasanka K BaruaT P RajeevSaumar J BaruahIntroduction and Objective: Nuclear renal scan is currently the gold standard imaging study to determine differential renal function. We propose helical CT as single modality for both the anatomical and functional evaluation of kidney with impaired function. In the present study renal parenchymal volume is measured and percent total renal volume is used as a surrogate marker for differential renal function. The objective of this study is to correlate between differential renal function estimation using CT-based renal parenchymal volume measurement with differential renal function estimation using 99m TC - DTPA renal scan. Materials and Methods: Twenty-one patients with unilateral obstructive uropathy were enrolled in this prospective comparative study. They were subjected to 99m Tc - DTPA renal scan and 64 slice helical CT scan which estimates the renal volume depending on the reconstruction of arterial phase images followed by volume rendering and percent renal volume was calculated. Percent renal volume was correlated with percent renal function, as determined by nuclear renal scan using Pearson coefficient. Results and Observation: A strong correlation is observed between percent renal volume and percent renal function in obstructed units (r = 0.828, P < 0.001) as well as in nonobstructed units (r = 0.827, P < 0.001). Conclusion: There is a strong correlation between percent renal volume determined by CT scan and percent renal function determined by 99m TC - DTPA renal scan both in obstructed and in normal units. CT-based percent renal volume can be used as a single radiological tests for both functional and anatomical assessment of impaired renal units.http://www.indianjurol.com/article.asp?issn=0970-1591;year=2012;volume=28;issue=4;spage=414;epage=417;aulast=SarmaDifferential renal functionDTPA renal scanfunctional renal parenchymal volume
spellingShingle Debanga Sarma
Sasanka K Barua
T P Rajeev
Saumar J Baruah
Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
Indian Journal of Urology
Differential renal function
DTPA renal scan
functional renal parenchymal volume
title Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
title_full Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
title_fullStr Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
title_full_unstemmed Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
title_short Correlation between differential renal function estimation using CT-based functional renal parenchymal volume and 99m Tc - DTPA renal scan
title_sort correlation between differential renal function estimation using ct based functional renal parenchymal volume and 99m tc dtpa renal scan
topic Differential renal function
DTPA renal scan
functional renal parenchymal volume
url http://www.indianjurol.com/article.asp?issn=0970-1591;year=2012;volume=28;issue=4;spage=414;epage=417;aulast=Sarma
work_keys_str_mv AT debangasarma correlationbetweendifferentialrenalfunctionestimationusingctbasedfunctionalrenalparenchymalvolumeand99mtcdtparenalscan
AT sasankakbarua correlationbetweendifferentialrenalfunctionestimationusingctbasedfunctionalrenalparenchymalvolumeand99mtcdtparenalscan
AT tprajeev correlationbetweendifferentialrenalfunctionestimationusingctbasedfunctionalrenalparenchymalvolumeand99mtcdtparenalscan
AT saumarjbaruah correlationbetweendifferentialrenalfunctionestimationusingctbasedfunctionalrenalparenchymalvolumeand99mtcdtparenalscan