Modular zonal fluid sampling and pressure testing technology for production well
To accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technology with the characteristics of modularization, full electronic control and rapidity...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
KeAi Communications Co., Ltd.
2022-04-01
|
Series: | Petroleum Exploration and Development |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1876380422600375 |
_version_ | 1818481497962708992 |
---|---|
author | Jianguo XU Qinghai YANG Peng YI Ze HOU Weite JIA Tao FU Zonglin ZHANG Qingfeng YUE |
author_facet | Jianguo XU Qinghai YANG Peng YI Ze HOU Weite JIA Tao FU Zonglin ZHANG Qingfeng YUE |
author_sort | Jianguo XU |
collection | DOAJ |
description | To accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technology with the characteristics of modularization, full electronic control and rapidity was proposed and developed. Lab testing and on-site testing was carried out. The modular zonal sampling and testing system is composed of 10 functional modules, namely ground control system, downhole power supply module, drainage pump, electronically controlled anchor, electronically controlled packer, electronically controlled sampler, magnetic positioning sub, terminal sub, adapter cable, and quick connector. Indoor tests have confirmed that the performance parameters of each module meet the design requirements. The downhole function modules of the system can withstand pressures up to 35 MPa and temperatures up to 85 °C. The rubber cylinder of the electronically controlled packer can withstand a pressure difference of more than 10 MPa. The electronically controlled anchor has an anchoring force of greater than 6.9 t, and can be forcibly detached in the event of an accident. The discharge pump has a displacement of 0.8 m3/d and a head of 500 m. The electronically controlled sampler can meet the requirement of taking 500 mL of sample in each of the 3 chambers. Field tests in Jilin Oilfield show that the system can realize rapid isolation and self-check of isolation of a certain production interval downhole, as well as layer-by layer pressure build-up test. The drainage pump can be used to discharge the mixed liquid between the upper and lower packers and near the wellbore to obtain real fluid samples of the tested formation interval. The data obtained give us better understanding on the pay zones in old oilfields, and provide important basis for development plan adjustment, reservoir stimulation, and EOR measures. |
first_indexed | 2024-12-10T11:35:43Z |
format | Article |
id | doaj.art-761bf34a3c6b4153b1129dcf75363d98 |
institution | Directory Open Access Journal |
issn | 1876-3804 |
language | English |
last_indexed | 2024-12-10T11:35:43Z |
publishDate | 2022-04-01 |
publisher | KeAi Communications Co., Ltd. |
record_format | Article |
series | Petroleum Exploration and Development |
spelling | doaj.art-761bf34a3c6b4153b1129dcf75363d982022-12-22T01:50:27ZengKeAi Communications Co., Ltd.Petroleum Exploration and Development1876-38042022-04-01492438447Modular zonal fluid sampling and pressure testing technology for production wellJianguo XU0Qinghai YANG1Peng YI2Ze HOU3Weite JIA4Tao FU5Zonglin ZHANG6Qingfeng YUE7Jilin Oilfield Oil & Gas Engineering Research Institute, Songyuan 138000, ChinaPetroChina Research Institute of Petroleum Exploration & Development, Beijing 100083, China; Corresponding authorJilin Oilfield Oil & Gas Engineering Research Institute, Songyuan 138000, ChinaJilin Oilfield Oil & Gas Engineering Research Institute, Songyuan 138000, ChinaJilin Oilfield Oil & Gas Engineering Research Institute, Songyuan 138000, ChinaPetroChina Research Institute of Petroleum Exploration & Development, Beijing 100083, ChinaJilin Oilfield Xinmu Production Plant, Songyuan 138000, ChinaDaqing Oilfield Production Engineering Research Institute, Daqing 163453, ChinaTo accurately obtain development dynamic data such as zonal pressure and fluid parameters of each oil layer in the late development stage of a high water-cut old oilfield, a modular zonal sampling and testing technology with the characteristics of modularization, full electronic control and rapidity was proposed and developed. Lab testing and on-site testing was carried out. The modular zonal sampling and testing system is composed of 10 functional modules, namely ground control system, downhole power supply module, drainage pump, electronically controlled anchor, electronically controlled packer, electronically controlled sampler, magnetic positioning sub, terminal sub, adapter cable, and quick connector. Indoor tests have confirmed that the performance parameters of each module meet the design requirements. The downhole function modules of the system can withstand pressures up to 35 MPa and temperatures up to 85 °C. The rubber cylinder of the electronically controlled packer can withstand a pressure difference of more than 10 MPa. The electronically controlled anchor has an anchoring force of greater than 6.9 t, and can be forcibly detached in the event of an accident. The discharge pump has a displacement of 0.8 m3/d and a head of 500 m. The electronically controlled sampler can meet the requirement of taking 500 mL of sample in each of the 3 chambers. Field tests in Jilin Oilfield show that the system can realize rapid isolation and self-check of isolation of a certain production interval downhole, as well as layer-by layer pressure build-up test. The drainage pump can be used to discharge the mixed liquid between the upper and lower packers and near the wellbore to obtain real fluid samples of the tested formation interval. The data obtained give us better understanding on the pay zones in old oilfields, and provide important basis for development plan adjustment, reservoir stimulation, and EOR measures.http://www.sciencedirect.com/science/article/pii/S1876380422600375zonal samplingzonal testingmodularizationfull electronic controlrapidityenhanced oil recovery |
spellingShingle | Jianguo XU Qinghai YANG Peng YI Ze HOU Weite JIA Tao FU Zonglin ZHANG Qingfeng YUE Modular zonal fluid sampling and pressure testing technology for production well Petroleum Exploration and Development zonal sampling zonal testing modularization full electronic control rapidity enhanced oil recovery |
title | Modular zonal fluid sampling and pressure testing technology for production well |
title_full | Modular zonal fluid sampling and pressure testing technology for production well |
title_fullStr | Modular zonal fluid sampling and pressure testing technology for production well |
title_full_unstemmed | Modular zonal fluid sampling and pressure testing technology for production well |
title_short | Modular zonal fluid sampling and pressure testing technology for production well |
title_sort | modular zonal fluid sampling and pressure testing technology for production well |
topic | zonal sampling zonal testing modularization full electronic control rapidity enhanced oil recovery |
url | http://www.sciencedirect.com/science/article/pii/S1876380422600375 |
work_keys_str_mv | AT jianguoxu modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT qinghaiyang modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT pengyi modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT zehou modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT weitejia modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT taofu modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT zonglinzhang modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell AT qingfengyue modularzonalfluidsamplingandpressuretestingtechnologyforproductionwell |