An innovative non-invasive technique for subcutaneous tumour measurements.
INTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. Ho...
Main Authors: | , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2019-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0216690 |
_version_ | 1819128352759349248 |
---|---|
author | Juan Delgado-SanMartin Beate Ehrhardt Marcin Paczkowski Sean Hackett Andrew Smith Wajahat Waraich James Klatzow Adeala Zabair Anna Chabokdast Leonardo Rubio-Navarro Amar Rahi Zena Wilson |
author_facet | Juan Delgado-SanMartin Beate Ehrhardt Marcin Paczkowski Sean Hackett Andrew Smith Wajahat Waraich James Klatzow Adeala Zabair Anna Chabokdast Leonardo Rubio-Navarro Amar Rahi Zena Wilson |
author_sort | Juan Delgado-SanMartin |
collection | DOAJ |
description | INTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. However, this method is subjective, insufficiently traceable, and is subject to error in the accuracy of volume estimates as tumours are frequently irregular. METHODS & RESULTS:This paper reviews the standard technique for tumour volume assessment, calliper measurements, by conducting a statistical review of a large dataset consisting of 2,500 tumour volume measurements from 1,600 mice by multiple operators across 6 mouse strains and 20 tumour models. Additionally, we explore the impact of six different tumour morphologies on volume estimation and the detection of treatment effects using a computational tumour growth model. Finally, we propose an alternative method to callipers for estimating volume-BioVolumeTM, a 3D scanning technique. BioVolume simultaneously captures both stereo RGB (Red, Green and Blue) images from different light sources and infrared thermal images of the tumour in under a second. It then detects the tumour region automatically and estimates the tumour volume in under a minute. Furthermore, images can be processed in parallel within the cloud and so the time required to process multiple images is similar to that required for a single image. We present data of a pre-production unit test consisting of 297 scans from over 120 mice collected by four different operators. CONCLUSION:This work demonstrates that it is possible to record tumour measurements in a rapid minimally invasive, morphology-independent way, and with less human-bias compared to callipers, whilst also improving data traceability. Furthermore, the images collected by BioVolume may be useful, for example, as a source of biomarkers for animal welfare and secondary drug toxicity / efficacy. |
first_indexed | 2024-12-22T08:26:28Z |
format | Article |
id | doaj.art-7638a866e5e14c709e95a8bca36d322f |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-22T08:26:28Z |
publishDate | 2019-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-7638a866e5e14c709e95a8bca36d322f2022-12-21T18:32:37ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011410e021669010.1371/journal.pone.0216690An innovative non-invasive technique for subcutaneous tumour measurements.Juan Delgado-SanMartinBeate EhrhardtMarcin PaczkowskiSean HackettAndrew SmithWajahat WaraichJames KlatzowAdeala ZabairAnna ChabokdastLeonardo Rubio-NavarroAmar RahiZena WilsonINTRODUCTION:In oncological drug development, animal studies continue to play a central role in which the volume of subcutaneous tumours is monitored to assess the efficacy of new drugs. The tumour volume is estimated by taking the volume to be that of a regular spheroid with the same dimensions. However, this method is subjective, insufficiently traceable, and is subject to error in the accuracy of volume estimates as tumours are frequently irregular. METHODS & RESULTS:This paper reviews the standard technique for tumour volume assessment, calliper measurements, by conducting a statistical review of a large dataset consisting of 2,500 tumour volume measurements from 1,600 mice by multiple operators across 6 mouse strains and 20 tumour models. Additionally, we explore the impact of six different tumour morphologies on volume estimation and the detection of treatment effects using a computational tumour growth model. Finally, we propose an alternative method to callipers for estimating volume-BioVolumeTM, a 3D scanning technique. BioVolume simultaneously captures both stereo RGB (Red, Green and Blue) images from different light sources and infrared thermal images of the tumour in under a second. It then detects the tumour region automatically and estimates the tumour volume in under a minute. Furthermore, images can be processed in parallel within the cloud and so the time required to process multiple images is similar to that required for a single image. We present data of a pre-production unit test consisting of 297 scans from over 120 mice collected by four different operators. CONCLUSION:This work demonstrates that it is possible to record tumour measurements in a rapid minimally invasive, morphology-independent way, and with less human-bias compared to callipers, whilst also improving data traceability. Furthermore, the images collected by BioVolume may be useful, for example, as a source of biomarkers for animal welfare and secondary drug toxicity / efficacy.https://doi.org/10.1371/journal.pone.0216690 |
spellingShingle | Juan Delgado-SanMartin Beate Ehrhardt Marcin Paczkowski Sean Hackett Andrew Smith Wajahat Waraich James Klatzow Adeala Zabair Anna Chabokdast Leonardo Rubio-Navarro Amar Rahi Zena Wilson An innovative non-invasive technique for subcutaneous tumour measurements. PLoS ONE |
title | An innovative non-invasive technique for subcutaneous tumour measurements. |
title_full | An innovative non-invasive technique for subcutaneous tumour measurements. |
title_fullStr | An innovative non-invasive technique for subcutaneous tumour measurements. |
title_full_unstemmed | An innovative non-invasive technique for subcutaneous tumour measurements. |
title_short | An innovative non-invasive technique for subcutaneous tumour measurements. |
title_sort | innovative non invasive technique for subcutaneous tumour measurements |
url | https://doi.org/10.1371/journal.pone.0216690 |
work_keys_str_mv | AT juandelgadosanmartin aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT beateehrhardt aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT marcinpaczkowski aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT seanhackett aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT andrewsmith aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT wajahatwaraich aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT jamesklatzow aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT adealazabair aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT annachabokdast aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT leonardorubionavarro aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT amarrahi aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT zenawilson aninnovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT juandelgadosanmartin innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT beateehrhardt innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT marcinpaczkowski innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT seanhackett innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT andrewsmith innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT wajahatwaraich innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT jamesklatzow innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT adealazabair innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT annachabokdast innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT leonardorubionavarro innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT amarrahi innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements AT zenawilson innovativenoninvasivetechniqueforsubcutaneoustumourmeasurements |