THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v

The NA62 experiment at CERN aims at the very challenging task of measuring with 10% relative error the Branching Ratio of the ultra-rare decay of the K<sup>+</sup> into π<sup>+</sup> ν¯ν which is expected to occur only in about 8 out of 10<sup>11</sup> Kaon decays...

Full description

Bibliographic Details
Main Author: Antonella Antonelli
Format: Article
Language:English
Published: CTU Central Library 2013-12-01
Series:Acta Polytechnica
Online Access:https://ojs.cvut.cz/ojs/index.php/ap/article/view/2000
_version_ 1818603325559406592
author Antonella Antonelli
author_facet Antonella Antonelli
author_sort Antonella Antonelli
collection DOAJ
description The NA62 experiment at CERN aims at the very challenging task of measuring with 10% relative error the Branching Ratio of the ultra-rare decay of the K<sup>+</sup> into π<sup>+</sup> ν¯ν which is expected to occur only in about 8 out of 10<sup>11</sup> Kaon decays. This will be achieved by means of an intense hadron beam, an accurate kinematical reconstruction and a redundant veto system for identifying and suppressing all spurious events. Good resolution on the missing mass in the decay is achieved using a high-resolution beam tracker to measure the kaon momentum and with a spectrometer equipped with straw tubes operating in vacuum. Hermetic veto (up to 50 mrad) of the photon from π<sup>0</sup> decays is achieved with a combination of large angle veto (with a creative reuse of the old OPAL lead glass blocks), the NA48 liquid Krypton calorimeter and two small angle calorimeters to cover the angle down to zero. The identification of the muons and the consequent veto is performed by a fast hodoscope plane (used in the first level of the trigger to reduce the rate) and by a 17 meter, neon-filled RICH counter which is able to separate pions and muons in the momentum interval between 15 and 35 GeV. Particle identification in the beam (K<sup>+</sup> separation) is achieved with an H2 differential Cherenkov counter. The trigger for the experiment is based on a multilevel structure with a first level implemented in the readout boards and with the subsequent level done in the software. The aim is to reduce the 10MHz level zero rate to a few kHz sent to the CERN computing centre. Studies are underway to use GPU boards in some key point of the trigger system to improve the performance.<p> </p>
first_indexed 2024-12-16T13:21:23Z
format Article
id doaj.art-7638be9a76544fa49e1cbfef36462e2f
institution Directory Open Access Journal
issn 1210-2709
1805-2363
language English
last_indexed 2024-12-16T13:21:23Z
publishDate 2013-12-01
publisher CTU Central Library
record_format Article
series Acta Polytechnica
spelling doaj.art-7638be9a76544fa49e1cbfef36462e2f2022-12-21T22:30:20ZengCTU Central LibraryActa Polytechnica1210-27091805-23632013-12-0153A10.14311/AP.2013.53.08141988THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;vAntonella Antonelli0I.N.F.N. – Laboratori Nazionali di Frascati, via E. Fermi 40, Frascati (Rome)The NA62 experiment at CERN aims at the very challenging task of measuring with 10% relative error the Branching Ratio of the ultra-rare decay of the K<sup>+</sup> into π<sup>+</sup> ν¯ν which is expected to occur only in about 8 out of 10<sup>11</sup> Kaon decays. This will be achieved by means of an intense hadron beam, an accurate kinematical reconstruction and a redundant veto system for identifying and suppressing all spurious events. Good resolution on the missing mass in the decay is achieved using a high-resolution beam tracker to measure the kaon momentum and with a spectrometer equipped with straw tubes operating in vacuum. Hermetic veto (up to 50 mrad) of the photon from π<sup>0</sup> decays is achieved with a combination of large angle veto (with a creative reuse of the old OPAL lead glass blocks), the NA48 liquid Krypton calorimeter and two small angle calorimeters to cover the angle down to zero. The identification of the muons and the consequent veto is performed by a fast hodoscope plane (used in the first level of the trigger to reduce the rate) and by a 17 meter, neon-filled RICH counter which is able to separate pions and muons in the momentum interval between 15 and 35 GeV. Particle identification in the beam (K<sup>+</sup> separation) is achieved with an H2 differential Cherenkov counter. The trigger for the experiment is based on a multilevel structure with a first level implemented in the readout boards and with the subsequent level done in the software. The aim is to reduce the 10MHz level zero rate to a few kHz sent to the CERN computing centre. Studies are underway to use GPU boards in some key point of the trigger system to improve the performance.<p> </p>https://ojs.cvut.cz/ojs/index.php/ap/article/view/2000
spellingShingle Antonella Antonelli
THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
Acta Polytechnica
title THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
title_full THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
title_fullStr THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
title_full_unstemmed THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
title_short THE NA62 EXPERIMENT AT CERN AND THE MEASUREMENT OF THE ULTRA-RARE DECAY K<sup>+</sup>-&pi;<sup>+</sup>v&macr;v
title_sort na62 experiment at cern and the measurement of the ultra rare decay k sup sup pi sup sup v macr v
url https://ojs.cvut.cz/ojs/index.php/ap/article/view/2000
work_keys_str_mv AT antonellaantonelli thena62experimentatcernandthemeasurementoftheultrararedecayksupsuppisupsupvmacrv
AT antonellaantonelli na62experimentatcernandthemeasurementoftheultrararedecayksupsuppisupsupvmacrv