Fatigue Performance of the Novel Titanium Alloy TIMETAL®407

TIMETAL®407 (Ti-407) is a novel titanium alloy formulated as a medium strength, highly ductile alloy offering a range of manufacturing cost reduction opportunities. It can be used as a direct replacement for Ti-6Al-4V or Ti-3Al-2.5V alloys, particularly in applications where energy absorption during...

Full description

Bibliographic Details
Main Authors: Davey W., Bache M.R., Davies H.M., Thomas M., Bermant-Parr I.
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2020/17/matecconf_ti2019_11044.pdf
Description
Summary:TIMETAL®407 (Ti-407) is a novel titanium alloy formulated as a medium strength, highly ductile alloy offering a range of manufacturing cost reduction opportunities. It can be used as a direct replacement for Ti-6Al-4V or Ti-3Al-2.5V alloys, particularly in applications where energy absorption during fracture or HCF endurance are the key design criteria. The effect of thermo-mechanical processing on microstructure has been characterised and the room temperature high cycle, low cycle and dwell cycle fatigue properties of Ti-407 containing 30-40% primary alpha volume fraction are presented and discussed. These results are compared with data generated from Ti-6Al-4V processed to provide a similar but non-standard microstructure and demonstrate that Ti-407 shows superior HCF endurance strength, despite having a significantly lower tensile and yield strength.
ISSN:2261-236X