Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol

Introduction: The importance of estimating patient-sized adjusted radiation dose for pediatric computed tomography (CT) has long been accepted. High doses of ionizing radiation to children are often common in chest CT examinations, as the volume CT dose index (CTDIvol) is measured by a 32 cm phantom...

Full description

Bibliographic Details
Main Authors: Fariba Zarei, Mahdokht Nasiri, Zahra Etemadi, Rezvan Ravanfar Haghighi, Sabysachi chatterjee, Pouria Abdollahi Khaneghah, Vani Vardhan Chatterjee
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2022-09-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:https://ijmp.mums.ac.ir/article_18925_37cbec0a349301549a50025be20dd56d.pdf
_version_ 1797848978968018944
author Fariba Zarei
Mahdokht Nasiri
Zahra Etemadi
Rezvan Ravanfar Haghighi
Sabysachi chatterjee
Pouria Abdollahi Khaneghah
Vani Vardhan Chatterjee
author_facet Fariba Zarei
Mahdokht Nasiri
Zahra Etemadi
Rezvan Ravanfar Haghighi
Sabysachi chatterjee
Pouria Abdollahi Khaneghah
Vani Vardhan Chatterjee
author_sort Fariba Zarei
collection DOAJ
description Introduction: The importance of estimating patient-sized adjusted radiation dose for pediatric computed tomography (CT) has long been accepted. High doses of ionizing radiation to children are often common in chest CT examinations, as the volume CT dose index (CTDIvol) is measured by a 32 cm phantom. Our study aimed to evaluate the effectiveness of size-specific dose estimate (SSDE) to compensate for the underestimated pediatric absorbed dose.      Material and Methods: CTDIvol and dose-length product (DLP) of 320 pediatric chest CT (<1, 1-5, 5-10, 10-15 years) were obtained from Picture-Archiving and Communication System (PACS) in a hospital affiliated with the Shiraz University of Medical Sciences. CTDIvol was converted to SSDE based on the patient's effective diameter. The Statistical Package for Social Science (SPSS) was used for data analysis.   Results: The variations between standard phantom (32cm) and the patients' mean effective diameter were approximately 65%, 57%, 47%, and 38%, across   <1, 1-5, 5-10, 10-15 year age groups, respectively.  The mean of SSDE for each age group was significantly higher than the corresponding CTDIvol values. Also, mean CTDIvol and SSDE values differed between age groups significantly (p<0.001). Results showed a strong correlation between age and the two-dose indicators, CTDIvol (0.361) and SSDE (0.184), with p<0.05. Conclusion: Pediatrics receive radiation doses comparable to the dose for adult-sized patients in chest CT protocol if the dosimetry procedure is not individualized. Thus, applying a size-based conversion coefficient is paramount in estimating the absorbed dose in pediatric chest CT.
first_indexed 2024-04-09T18:36:23Z
format Article
id doaj.art-7659780a3f12486b8bb47d9cccad6f7f
institution Directory Open Access Journal
issn 2345-3672
language English
last_indexed 2024-04-09T18:36:23Z
publishDate 2022-09-01
publisher Mashhad University of Medical Sciences
record_format Article
series Iranian Journal of Medical Physics
spelling doaj.art-7659780a3f12486b8bb47d9cccad6f7f2023-04-11T09:41:57ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722022-09-0119531532110.22038/ijmp.2021.56852.195418925Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT ProtocolFariba Zarei0Mahdokht Nasiri1Zahra Etemadi2Rezvan Ravanfar Haghighi3Sabysachi chatterjee4Pouria Abdollahi Khaneghah5Vani Vardhan Chatterjee6Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran Department of Radiology, School of Medicine, Shiraz University of Medical Sciences, Shiraz 7134845794, Iran.Department of Radiology, School of Medicine, Shiraz University of Medical Sciences, Shiraz 7134845794, Iran.Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz 7134845794, IranMedical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, IranRetired Scientist from Indian Institute of Astrophysics, present affiliation: Ongil, 79 D3, Sivaya Nagar, Reddiyur Alagapuram, Salem 636004. IndiaDepartment of Radiology, Shiraz University of Medical Sciences, Shiraz 7134845794, IranDepartment of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012. INDIAIntroduction: The importance of estimating patient-sized adjusted radiation dose for pediatric computed tomography (CT) has long been accepted. High doses of ionizing radiation to children are often common in chest CT examinations, as the volume CT dose index (CTDIvol) is measured by a 32 cm phantom. Our study aimed to evaluate the effectiveness of size-specific dose estimate (SSDE) to compensate for the underestimated pediatric absorbed dose.      Material and Methods: CTDIvol and dose-length product (DLP) of 320 pediatric chest CT (<1, 1-5, 5-10, 10-15 years) were obtained from Picture-Archiving and Communication System (PACS) in a hospital affiliated with the Shiraz University of Medical Sciences. CTDIvol was converted to SSDE based on the patient's effective diameter. The Statistical Package for Social Science (SPSS) was used for data analysis.   Results: The variations between standard phantom (32cm) and the patients' mean effective diameter were approximately 65%, 57%, 47%, and 38%, across   <1, 1-5, 5-10, 10-15 year age groups, respectively.  The mean of SSDE for each age group was significantly higher than the corresponding CTDIvol values. Also, mean CTDIvol and SSDE values differed between age groups significantly (p<0.001). Results showed a strong correlation between age and the two-dose indicators, CTDIvol (0.361) and SSDE (0.184), with p<0.05. Conclusion: Pediatrics receive radiation doses comparable to the dose for adult-sized patients in chest CT protocol if the dosimetry procedure is not individualized. Thus, applying a size-based conversion coefficient is paramount in estimating the absorbed dose in pediatric chest CT.https://ijmp.mums.ac.ir/article_18925_37cbec0a349301549a50025be20dd56d.pdfxray computed tomography chest sizespecific dose estimate (ssde) paediatric
spellingShingle Fariba Zarei
Mahdokht Nasiri
Zahra Etemadi
Rezvan Ravanfar Haghighi
Sabysachi chatterjee
Pouria Abdollahi Khaneghah
Vani Vardhan Chatterjee
Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
Iranian Journal of Medical Physics
x
ray computed tomography chest size
specific dose estimate (ssde) paediatric
title Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
title_full Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
title_fullStr Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
title_full_unstemmed Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
title_short Evaluation of Size-Specific Dose Estimates for Optimizing Pediatric Chest CT Protocol
title_sort evaluation of size specific dose estimates for optimizing pediatric chest ct protocol
topic x
ray computed tomography chest size
specific dose estimate (ssde) paediatric
url https://ijmp.mums.ac.ir/article_18925_37cbec0a349301549a50025be20dd56d.pdf
work_keys_str_mv AT faribazarei evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT mahdokhtnasiri evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT zahraetemadi evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT rezvanravanfarhaghighi evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT sabysachichatterjee evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT pouriaabdollahikhaneghah evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol
AT vanivardhanchatterjee evaluationofsizespecificdoseestimatesforoptimizingpediatricchestctprotocol