Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM
To improve the ergonomic reliability of medical equipment design during the operation process, a method for evaluating the operating procedure of a medical equipment interface according to functional resonance analysis method (FRAM)-Moran’s I and cognitive reliability and error analysis method (CREA...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-12-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/12/1/200 |
_version_ | 1797499642553827328 |
---|---|
author | Xin Liu Zheng Liu Kang-Chao Lin Zhi-Lin Huang Ming-Yu Ling Peng-Qing Chen Xiao-Min Huang Yu-Jia Zhai |
author_facet | Xin Liu Zheng Liu Kang-Chao Lin Zhi-Lin Huang Ming-Yu Ling Peng-Qing Chen Xiao-Min Huang Yu-Jia Zhai |
author_sort | Xin Liu |
collection | DOAJ |
description | To improve the ergonomic reliability of medical equipment design during the operation process, a method for evaluating the operating procedure of a medical equipment interface according to functional resonance analysis method (FRAM)-Moran’s I and cognitive reliability and error analysis method (CREAM) is proposed in this study. The novelty of this research is to analyze the ergonomic reliability of medical equipment in a more systematic manner and to minimize the impact of human subjectivity and individual differences on the evaluation results of the operation process. To solve the calculation problem of functional resonance in FRAM and to make the evaluation results more objective, Moran’s I was introduced to quantify the deviation degree caused by the individual differences of the subjects. By giving weights based on Moran’s I, the influence of individual differences and subjectivity on the evaluation results can be minimized, to a certain extent. Considering the importance of a special environment, which is not fully considered by the conventional CREAM, the weighting values based on Moran’s I, Delphi survey, and technique for order preference by similarity to an ideal solution (TOPSIS) were adopted to assign weights to common performance conditions (CPCs) in CREAM. The optimal design scheme was selected more objectively than in the conventional method. The validity and practicability of this operation process evaluation method was verified by a statistical method based on ergonomic reliability experiments. |
first_indexed | 2024-03-10T03:50:20Z |
format | Article |
id | doaj.art-766137a86c55479cbaf53231c3fa28d1 |
institution | Directory Open Access Journal |
issn | 2076-3417 |
language | English |
last_indexed | 2024-03-10T03:50:20Z |
publishDate | 2021-12-01 |
publisher | MDPI AG |
record_format | Article |
series | Applied Sciences |
spelling | doaj.art-766137a86c55479cbaf53231c3fa28d12023-11-23T11:09:16ZengMDPI AGApplied Sciences2076-34172021-12-0112120010.3390/app12010200Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAMXin Liu0Zheng Liu1Kang-Chao Lin2Zhi-Lin Huang3Ming-Yu Ling4Peng-Qing Chen5Xiao-Min Huang6Yu-Jia Zhai7Research Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaSchool of Mechanical and Electric Engineering, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaResearch Institute of Industrial Design, Guangzhou University, GZHU, Guangzhou 510006, ChinaTo improve the ergonomic reliability of medical equipment design during the operation process, a method for evaluating the operating procedure of a medical equipment interface according to functional resonance analysis method (FRAM)-Moran’s I and cognitive reliability and error analysis method (CREAM) is proposed in this study. The novelty of this research is to analyze the ergonomic reliability of medical equipment in a more systematic manner and to minimize the impact of human subjectivity and individual differences on the evaluation results of the operation process. To solve the calculation problem of functional resonance in FRAM and to make the evaluation results more objective, Moran’s I was introduced to quantify the deviation degree caused by the individual differences of the subjects. By giving weights based on Moran’s I, the influence of individual differences and subjectivity on the evaluation results can be minimized, to a certain extent. Considering the importance of a special environment, which is not fully considered by the conventional CREAM, the weighting values based on Moran’s I, Delphi survey, and technique for order preference by similarity to an ideal solution (TOPSIS) were adopted to assign weights to common performance conditions (CPCs) in CREAM. The optimal design scheme was selected more objectively than in the conventional method. The validity and practicability of this operation process evaluation method was verified by a statistical method based on ergonomic reliability experiments.https://www.mdpi.com/2076-3417/12/1/200reliabilitymedical equipmentoperation process analysisergonomic |
spellingShingle | Xin Liu Zheng Liu Kang-Chao Lin Zhi-Lin Huang Ming-Yu Ling Peng-Qing Chen Xiao-Min Huang Yu-Jia Zhai Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM Applied Sciences reliability medical equipment operation process analysis ergonomic |
title | Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM |
title_full | Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM |
title_fullStr | Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM |
title_full_unstemmed | Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM |
title_short | Evaluation of the Operation Process of Medical Equipment to Enhance Ergonomic Reliability Based on FRAM–Moran’s I and CREAM |
title_sort | evaluation of the operation process of medical equipment to enhance ergonomic reliability based on fram moran s i and cream |
topic | reliability medical equipment operation process analysis ergonomic |
url | https://www.mdpi.com/2076-3417/12/1/200 |
work_keys_str_mv | AT xinliu evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT zhengliu evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT kangchaolin evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT zhilinhuang evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT mingyuling evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT pengqingchen evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT xiaominhuang evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream AT yujiazhai evaluationoftheoperationprocessofmedicalequipmenttoenhanceergonomicreliabilitybasedonframmoransiandcream |