Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor

Cosmic rays interact with atmospheric atoms to generate high�energy neutron radiation, which threats to the electronic system working in the atmospheric space environment. Neutron�induced single event effect (SEE) occurring in the key component of an electronic system (i.e. microprocessor) seriously...

Full description

Bibliographic Details
Main Author: DUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou
Format: Article
Language:English
Published: Editorial Board of Atomic Energy Science and Technology 2022-04-01
Series:Yuanzineng kexue jishu
Subjects:
Online Access:https://www.aest.org.cn/CN/10.7538/yzk.2021.youxian.0786
_version_ 1811216859911946240
author DUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou
author_facet DUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou
author_sort DUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou
collection DOAJ
description Cosmic rays interact with atmospheric atoms to generate high�energy neutron radiation, which threats to the electronic system working in the atmospheric space environment. Neutron�induced single event effect (SEE) occurring in the key component of an electronic system (i.e. microprocessor) seriously affects the system reliability. To study neutron�induced SEE of microprocessor, a SEE monitoring system was designed for a 65 nm CMOS microprocessor from Texas Instruments (TI). The designed system has the ability to monitor SEE events that occur in tested microprocessor, and record corresponding voltage/current change in real time. To minimize the irradiation�caused disturbance in monitoring system, it consists of two modules connected with 1�2 m communication line in irradiation room. One module carrying tested microprocessor is placed close to the neutron source. Another module acting as the master control board is placed as far away from the neutron source and is shielded against gamma ray with lead bricks. The upper order computer and 24 V direct�current (DC) power supply are placed outside of the irradiation room. As a key component of the SEE monitoring system, the master control board is composed of microcontroller unit (MCU), power management chip, operating voltage/current monitor and peripheral circuit. The master control board is able to continuously monitor the internal operating status of the tested microprocessor and the voltage/current fluctuation. The 24 V input voltage is converted into two�way power supplies. One is used for monitoring MCUs on master control board. Another one is used for the device under test (DUT). Operating voltage/current values are transferred to the upper order computer through a serial port. When the detected voltage or current values exceed set thresholds, monitoring MCU would cut off power supply through a relay. The SEE monitoring system was test using 14 MeV neutrons produced by D�T reactions. Single event functional interrupt (SEFI) was observed in inter�integrated circuit (I2C), internal flash memory, analog�to�digital converter (ADC), arithmetic and logic unit (ALU), controller area network (CAN), general�purpose input/output (GPIO) and other units, while single event latch up (SEL) is not detected. I2C is found to be the most sensitive unit. Neutron�induced SEE in I2C bus leads to a significant operating current drop. Moreover, when one of eight tested I2C buses is blocked under neutron irradiation, the following tests for rest I2C bus will turn out to be “FAIL” too, which implies the SEE might occur at the control part of I2C. The SEE cross�section of tested microprocessor is evaluated to be 6�6×10-11 cm2 with the data of neutron fluence up to 3�5×1011 cm-2.
first_indexed 2024-04-12T06:45:59Z
format Article
id doaj.art-766b567e7c014d1d897829648a03d33a
institution Directory Open Access Journal
issn 1000-6931
language English
last_indexed 2024-04-12T06:45:59Z
publishDate 2022-04-01
publisher Editorial Board of Atomic Energy Science and Technology
record_format Article
series Yuanzineng kexue jishu
spelling doaj.art-766b567e7c014d1d897829648a03d33a2022-12-22T03:43:34ZengEditorial Board of Atomic Energy Science and TechnologyYuanzineng kexue jishu1000-69312022-04-01564 734741Design and Test of Neutron-induced Single Event Effect Monitoring System on MicroprocessorDUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou 0Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang 621999, China;National Space Science Center, Chinese Academy of Sciences, Beijing 100190, ChinaCosmic rays interact with atmospheric atoms to generate high�energy neutron radiation, which threats to the electronic system working in the atmospheric space environment. Neutron�induced single event effect (SEE) occurring in the key component of an electronic system (i.e. microprocessor) seriously affects the system reliability. To study neutron�induced SEE of microprocessor, a SEE monitoring system was designed for a 65 nm CMOS microprocessor from Texas Instruments (TI). The designed system has the ability to monitor SEE events that occur in tested microprocessor, and record corresponding voltage/current change in real time. To minimize the irradiation�caused disturbance in monitoring system, it consists of two modules connected with 1�2 m communication line in irradiation room. One module carrying tested microprocessor is placed close to the neutron source. Another module acting as the master control board is placed as far away from the neutron source and is shielded against gamma ray with lead bricks. The upper order computer and 24 V direct�current (DC) power supply are placed outside of the irradiation room. As a key component of the SEE monitoring system, the master control board is composed of microcontroller unit (MCU), power management chip, operating voltage/current monitor and peripheral circuit. The master control board is able to continuously monitor the internal operating status of the tested microprocessor and the voltage/current fluctuation. The 24 V input voltage is converted into two�way power supplies. One is used for monitoring MCUs on master control board. Another one is used for the device under test (DUT). Operating voltage/current values are transferred to the upper order computer through a serial port. When the detected voltage or current values exceed set thresholds, monitoring MCU would cut off power supply through a relay. The SEE monitoring system was test using 14 MeV neutrons produced by D�T reactions. Single event functional interrupt (SEFI) was observed in inter�integrated circuit (I2C), internal flash memory, analog�to�digital converter (ADC), arithmetic and logic unit (ALU), controller area network (CAN), general�purpose input/output (GPIO) and other units, while single event latch up (SEL) is not detected. I2C is found to be the most sensitive unit. Neutron�induced SEE in I2C bus leads to a significant operating current drop. Moreover, when one of eight tested I2C buses is blocked under neutron irradiation, the following tests for rest I2C bus will turn out to be “FAIL” too, which implies the SEE might occur at the control part of I2C. The SEE cross�section of tested microprocessor is evaluated to be 6�6×10-11 cm2 with the data of neutron fluence up to 3�5×1011 cm-2.https://www.aest.org.cn/CN/10.7538/yzk.2021.youxian.0786microprocessorneutron-induced single event effect14 mev neutrontesting system
spellingShingle DUAN Binghuang;DU Chuanhua;ZHU Xiaofeng;LI Yue;CHEN Quanyou
Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
Yuanzineng kexue jishu
microprocessor
neutron-induced single event effect
14 mev neutron
testing system
title Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
title_full Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
title_fullStr Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
title_full_unstemmed Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
title_short Design and Test of Neutron-induced Single Event Effect Monitoring System on Microprocessor
title_sort design and test of neutron induced single event effect monitoring system on microprocessor
topic microprocessor
neutron-induced single event effect
14 mev neutron
testing system
url https://www.aest.org.cn/CN/10.7538/yzk.2021.youxian.0786
work_keys_str_mv AT duanbinghuangduchuanhuazhuxiaofengliyuechenquanyou designandtestofneutroninducedsingleeventeffectmonitoringsystemonmicroprocessor