Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions

Abdominal respiratory sensor is a sensor used to detect sleep apnea that is specifically for neonates, this sensor is specifically for neonates because the use of this sensor does not require a voltage input to activate the sensor. In the absence of voltage input so as not to disturb the heart rhyth...

Full description

Bibliographic Details
Main Authors: Dimas Adi tya, Endro Yulianto, Sumber Sumber
Format: Article
Language:English
Published: Poltekkes Kemenkes Surabaya 2023-03-01
Series:Jurnal Teknokes
Subjects:
Online Access:https://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/494
_version_ 1797266987055841280
author Dimas Adi tya
Endro Yulianto
Sumber Sumber
author_facet Dimas Adi tya
Endro Yulianto
Sumber Sumber
author_sort Dimas Adi tya
collection DOAJ
description Abdominal respiratory sensor is a sensor used to detect sleep apnea that is specifically for neonates, this sensor is specifically for neonates because the use of this sensor does not require a voltage input to activate the sensor. In the absence of voltage input so as not to disturb the heart rhythm in neonates. When the sensor is no longer elastic, the pressure difference generated by the sensor will be unstable so that the sensor cannot work optimally. With these conditions, the period of use of the sensor needs to be known how durable the sensor is when it is used on patients so that the sensor can maximally detect the occurrence of apnea in neonates. How many times have you been in apnea. This study uses an Arduino microcontroller to process the pressure value and RR value generated by the stomach sensor and the MPX5010dp pressure sensor. the research method used is to use a simulator to analyze the combination of abdominal sensors and pressure sensors to monitor apnea. If viewed based on the average error, the error value in the RR 10bpm setting is ±0.185%, the RR 15 setting is ±0.245%, and the setting RR 20bpm is ±0.383%. From the average error value, it can be said that the higher the RR setting value, the higher the average error for each decrease in pressure output. it can be concluded that the performance of the use of the Abdominal Respiratory Sensor and Pressure Sensor on the Apnea Monitoring module functions well in detecting RR according to the settings on the simulator for 3-day monitoring. The development that can be done in this research is to use a more sensitive pressure sensor so that the results obtained are more stable and make the module display more attractive.
first_indexed 2024-04-25T01:09:25Z
format Article
id doaj.art-770519025ea4450fb90038b26db39d53
institution Directory Open Access Journal
issn 2407-8964
language English
last_indexed 2024-04-25T01:09:25Z
publishDate 2023-03-01
publisher Poltekkes Kemenkes Surabaya
record_format Article
series Jurnal Teknokes
spelling doaj.art-770519025ea4450fb90038b26db39d532024-03-10T10:19:04ZengPoltekkes Kemenkes SurabayaJurnal Teknokes2407-89642023-03-01161212910.35882/teknokes.v16i1.494494Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea ConditionsDimas Adi tya0Endro Yulianto1Sumber Sumber2-Department of electromedical engineering poltekkes Kemenkes surabayaDepartment of electromedical engineering poltekkes Kemenkes surabayaAbdominal respiratory sensor is a sensor used to detect sleep apnea that is specifically for neonates, this sensor is specifically for neonates because the use of this sensor does not require a voltage input to activate the sensor. In the absence of voltage input so as not to disturb the heart rhythm in neonates. When the sensor is no longer elastic, the pressure difference generated by the sensor will be unstable so that the sensor cannot work optimally. With these conditions, the period of use of the sensor needs to be known how durable the sensor is when it is used on patients so that the sensor can maximally detect the occurrence of apnea in neonates. How many times have you been in apnea. This study uses an Arduino microcontroller to process the pressure value and RR value generated by the stomach sensor and the MPX5010dp pressure sensor. the research method used is to use a simulator to analyze the combination of abdominal sensors and pressure sensors to monitor apnea. If viewed based on the average error, the error value in the RR 10bpm setting is ±0.185%, the RR 15 setting is ±0.245%, and the setting RR 20bpm is ±0.383%. From the average error value, it can be said that the higher the RR setting value, the higher the average error for each decrease in pressure output. it can be concluded that the performance of the use of the Abdominal Respiratory Sensor and Pressure Sensor on the Apnea Monitoring module functions well in detecting RR according to the settings on the simulator for 3-day monitoring. The development that can be done in this research is to use a more sensitive pressure sensor so that the results obtained are more stable and make the module display more attractive.https://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/494abdominal respiratory sensor, mpx5700, apnea
spellingShingle Dimas Adi tya
Endro Yulianto
Sumber Sumber
Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
Jurnal Teknokes
abdominal respiratory sensor, mpx5700, apnea
title Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
title_full Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
title_fullStr Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
title_full_unstemmed Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
title_short Analysis of Abdominal Respiratory Sensor Performance in Sleep Apnea Conditions
title_sort analysis of abdominal respiratory sensor performance in sleep apnea conditions
topic abdominal respiratory sensor, mpx5700, apnea
url https://teknokes.poltekkesdepkes-sby.ac.id/index.php/Teknokes/article/view/494
work_keys_str_mv AT dimasaditya analysisofabdominalrespiratorysensorperformanceinsleepapneaconditions
AT endroyulianto analysisofabdominalrespiratorysensorperformanceinsleepapneaconditions
AT sumbersumber analysisofabdominalrespiratorysensorperformanceinsleepapneaconditions