Failure of pillar of sports and entertainment hall structure

This paper deals with the failure of one of the sports and entertainment halls in Poland. The facility was built in the years 1977-85. Its main load-bearing members were three-hinged double-sloped frames with a total span of 45 m. The main girders of the frames were made of glued-laminated timber. T...

Full description

Bibliographic Details
Main Authors: Trapko Tomasz, Musiał Michał, Ubysz Andrzej
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201814602008
_version_ 1818827617843806208
author Trapko Tomasz
Musiał Michał
Ubysz Andrzej
author_facet Trapko Tomasz
Musiał Michał
Ubysz Andrzej
author_sort Trapko Tomasz
collection DOAJ
description This paper deals with the failure of one of the sports and entertainment halls in Poland. The facility was built in the years 1977-85. Its main load-bearing members were three-hinged double-sloped frames with a total span of 45 m. The main girders of the frames were made of glued-laminated timber. The girders rest on reinforced concrete pillars. Because of the considerable expansion forces the facility was founded on concrete padstones. In the summer of 2016 one of the reinforced concrete pillars was found to have failed. It was established that the failure condition was mainly due to construction errors. A way of strengthening all the pillars with additional RC members was proposed.
first_indexed 2024-12-19T00:46:25Z
format Article
id doaj.art-7755dacd8a994024b8982739dd72ef4e
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-12-19T00:46:25Z
publishDate 2018-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-7755dacd8a994024b8982739dd72ef4e2022-12-21T20:44:15ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011460200810.1051/matecconf/201814602008matecconf_bd2018_02008Failure of pillar of sports and entertainment hall structureTrapko TomaszMusiał MichałUbysz AndrzejThis paper deals with the failure of one of the sports and entertainment halls in Poland. The facility was built in the years 1977-85. Its main load-bearing members were three-hinged double-sloped frames with a total span of 45 m. The main girders of the frames were made of glued-laminated timber. The girders rest on reinforced concrete pillars. Because of the considerable expansion forces the facility was founded on concrete padstones. In the summer of 2016 one of the reinforced concrete pillars was found to have failed. It was established that the failure condition was mainly due to construction errors. A way of strengthening all the pillars with additional RC members was proposed.https://doi.org/10.1051/matecconf/201814602008
spellingShingle Trapko Tomasz
Musiał Michał
Ubysz Andrzej
Failure of pillar of sports and entertainment hall structure
MATEC Web of Conferences
title Failure of pillar of sports and entertainment hall structure
title_full Failure of pillar of sports and entertainment hall structure
title_fullStr Failure of pillar of sports and entertainment hall structure
title_full_unstemmed Failure of pillar of sports and entertainment hall structure
title_short Failure of pillar of sports and entertainment hall structure
title_sort failure of pillar of sports and entertainment hall structure
url https://doi.org/10.1051/matecconf/201814602008
work_keys_str_mv AT trapkotomasz failureofpillarofsportsandentertainmenthallstructure
AT musiałmichał failureofpillarofsportsandentertainmenthallstructure
AT ubyszandrzej failureofpillarofsportsandentertainmenthallstructure