Flow Pulsation Characteristic of External Gear Pump and Analysis of Influencing Factor
Based on the bench test of oil pump, the influence of pump outlet pressure on flow pulsation of external gear oil pump is analyzed. The results show that the flow pulsation coefficient of the oil pump decreased with the increase of pump outlet pressure. The effects of different teeth number, modulus...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Mechanical Transmission
2020-01-01
|
Series: | Jixie chuandong |
Subjects: | |
Online Access: | http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2020.01.022 |