Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater

<em>Quality assurance is one of the technical requirements that include in the quality management system based on SNI ISO/IEC 17025 : 2008. Quality assurance is all the process that planned and systematic activity that applied in analysis, so can give the confidence to the customer or data use...

Full description

Bibliographic Details
Main Author: Uray Lusiana
Format: Article
Language:Indonesian
Published: Balai Riset dan Standardisasi Industri Pontianak 2012-06-01
Series:Biopropal Industri
Subjects:
Online Access:http://ejournal.kemenperin.go.id/biopropal/article/view/732
_version_ 1818023666148966400
author Uray Lusiana
author_facet Uray Lusiana
author_sort Uray Lusiana
collection DOAJ
description <em>Quality assurance is one of the technical requirements that include in the quality management system based on SNI ISO/IEC 17025 : 2008. Quality assurance is all the process that planned and systematic activity that applied in analysis, so can give the confidence to the customer or data user. Quality assurance that is applied for COD testing in wastewater are calibration curve, accuracy and precision control chart. The purpose of calibration curve, accuracy and precision control chart applied was to control the data of COD testing so that guaranty the validity to report and to keep the consistence of testing result as statistic all the time. Calibration curve of COD testing have a coefficient correlation 0,99987. Accuracy control chart have limited line </em><em>BTA = 104,95%, BPA = 102,97%, BIA = 100,98%, BTB = 93,03%, BPB = 95,02% and BIB = 97,0%. Accuracy data can be accepted if that data present between line of BPA and BPB (± 2 SD), data is warned if that data present between line BTA-BPA or BTB-BPB (± 2 SD and ± 3 SD), and data is outlier if that data present out of line BTA and BTB (± 3 SD). The precision data can accepted if that the RPD value is not more than 10 % of COD testing result.</em>
first_indexed 2024-12-10T03:47:57Z
format Article
id doaj.art-77791d716a0a4ec28a836c102238d725
institution Directory Open Access Journal
issn 2089-0877
2502-2962
language Indonesian
last_indexed 2024-12-10T03:47:57Z
publishDate 2012-06-01
publisher Balai Riset dan Standardisasi Industri Pontianak
record_format Article
series Biopropal Industri
spelling doaj.art-77791d716a0a4ec28a836c102238d7252022-12-22T02:03:22ZindBalai Riset dan Standardisasi Industri PontianakBiopropal Industri2089-08772502-29622012-06-0131657Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in WastewaterUray Lusiana0Baristand Industri Pontinak<em>Quality assurance is one of the technical requirements that include in the quality management system based on SNI ISO/IEC 17025 : 2008. Quality assurance is all the process that planned and systematic activity that applied in analysis, so can give the confidence to the customer or data user. Quality assurance that is applied for COD testing in wastewater are calibration curve, accuracy and precision control chart. The purpose of calibration curve, accuracy and precision control chart applied was to control the data of COD testing so that guaranty the validity to report and to keep the consistence of testing result as statistic all the time. Calibration curve of COD testing have a coefficient correlation 0,99987. Accuracy control chart have limited line </em><em>BTA = 104,95%, BPA = 102,97%, BIA = 100,98%, BTB = 93,03%, BPB = 95,02% and BIB = 97,0%. Accuracy data can be accepted if that data present between line of BPA and BPB (± 2 SD), data is warned if that data present between line BTA-BPA or BTB-BPB (± 2 SD and ± 3 SD), and data is outlier if that data present out of line BTA and BTB (± 3 SD). The precision data can accepted if that the RPD value is not more than 10 % of COD testing result.</em>http://ejournal.kemenperin.go.id/biopropal/article/view/732accuracycalibration curvecontrol chartprecisionquality assurance
spellingShingle Uray Lusiana
Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
Biopropal Industri
accuracy
calibration curve
control chart
precision
quality assurance
title Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
title_full Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
title_fullStr Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
title_full_unstemmed Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
title_short Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater
title_sort application of calibration curve accuracy and precision chart as internal quality control at cod testing in wastewater
topic accuracy
calibration curve
control chart
precision
quality assurance
url http://ejournal.kemenperin.go.id/biopropal/article/view/732
work_keys_str_mv AT uraylusiana applicationofcalibrationcurveaccuracyandprecisionchartasinternalqualitycontrolatcodtestinginwastewater