Low Diopter Phakic Implantable Collamer Lens: Refractive and Visual Outcomes in Low Myopia and Myopic Astigmatism

Ernesto Alonso-Juárez,1 Daniel Velázquez-Villoria2 1INSADOF Clinic, Salamanca, Spain; 2Villoria Clinic, Vigo & Pontevedra, SpainCorrespondence: Ernesto Alonso-Juárez, INSADOF, Calle Doctrinos, 4, 1, Salamanca, 37002, Spain, Email info@insadof.comPurpose: Nowadays the Implantable Collamer Lens (I...

Full description

Bibliographic Details
Main Authors: Alonso-Juárez E, Velázquez-Villoria D
Format: Article
Language:English
Published: Dove Medical Press 2022-09-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/low-diopter-phakic-implantable-collamer-lens-refractive-and-visual-out-peer-reviewed-fulltext-article-OPTH
Description
Summary:Ernesto Alonso-Juárez,1 Daniel Velázquez-Villoria2 1INSADOF Clinic, Salamanca, Spain; 2Villoria Clinic, Vigo & Pontevedra, SpainCorrespondence: Ernesto Alonso-Juárez, INSADOF, Calle Doctrinos, 4, 1, Salamanca, 37002, Spain, Email info@insadof.comPurpose: Nowadays the Implantable Collamer Lens (ICL – STAAR Surgical. Monrovia. CA) is a refractive surgical technique offered not only when laser corneal correction is not possible but also when the patient requires premium quality indexes and when dry eye is a concern. The use of ICL phakic lenses in low myopic patients is an emanate factor to study and analyze in order to determine treatment predictability and stability in such patients. In this paper, we conducted a 1-year follow-up study on patients with myopia below − 3.5D implanted with ICL lenses.Methods: This was a retrospective analytical study that includes patients with phakic ICL implantation from 2 independent clinics with a minimum follow-up of 12 months. Visual acuity, refractive outcomes, vault, and intraocular pressure (IOP) were assessed at 1, 6 and 12 months.Results: Eighty-two eyes from 82 patients were included in this analysis. Mean spherical equivalent was − 2.34 ± 0.82 (Range − 5.50 to − 1.00 D). Mean spherical implanted ICL power was − 3.04 ± 0.78 D. In 25 eyes (30.5%) a Toric-ICL (TICL) was implanted with a mean TICL cylinder power of +1.64± 0.64. Efficacy and security index remained stable for 12 months at 1.07 and 1.09, respectively. Mean vault at 12 months was 513.78 ± 262.87 μm and IOP was 15.63 ± 2.17 mmHg.Conclusion: Phakic Implantable Collamer Lens implantation in very low myopia is a predictable, stable, safe, and effective technique with high efficacy and security indexes. Low diopter Toric ICL is also an excellent option for refractive surgery in cases of low diopter astigmatism.Keywords: low myopia, phakic intraocular low power lens, refractive surgery
ISSN:1177-5483