Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
American Physical Society
2023-02-01
|
Series: | PRX Quantum |
Online Access: | http://doi.org/10.1103/PRXQuantum.4.010322 |
_version_ | 1811163377191354368 |
---|---|
author | Mingrui Xu Risheng Cheng Yufeng Wu Gangqiang Liu Hong X. Tang |
author_facet | Mingrui Xu Risheng Cheng Yufeng Wu Gangqiang Liu Hong X. Tang |
author_sort | Mingrui Xu |
collection | DOAJ |
description | Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spin-ensemble quantum memories. To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB. The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59±0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta. Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment. This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions. |
first_indexed | 2024-04-10T06:44:03Z |
format | Article |
id | doaj.art-77ddc14f906d4153a915752e08afbc63 |
institution | Directory Open Access Journal |
issn | 2691-3399 |
language | English |
last_indexed | 2024-04-10T06:44:03Z |
publishDate | 2023-02-01 |
publisher | American Physical Society |
record_format | Article |
series | PRX Quantum |
spelling | doaj.art-77ddc14f906d4153a915752e08afbc632023-02-28T15:14:29ZengAmerican Physical SocietyPRX Quantum2691-33992023-02-014101032210.1103/PRXQuantum.4.010322Magnetic Field-Resilient Quantum-Limited Parametric AmplifierMingrui XuRisheng ChengYufeng WuGangqiang LiuHong X. TangSuperconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spin-ensemble quantum memories. To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB. The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59±0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta. Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment. This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions.http://doi.org/10.1103/PRXQuantum.4.010322 |
spellingShingle | Mingrui Xu Risheng Cheng Yufeng Wu Gangqiang Liu Hong X. Tang Magnetic Field-Resilient Quantum-Limited Parametric Amplifier PRX Quantum |
title | Magnetic Field-Resilient Quantum-Limited Parametric Amplifier |
title_full | Magnetic Field-Resilient Quantum-Limited Parametric Amplifier |
title_fullStr | Magnetic Field-Resilient Quantum-Limited Parametric Amplifier |
title_full_unstemmed | Magnetic Field-Resilient Quantum-Limited Parametric Amplifier |
title_short | Magnetic Field-Resilient Quantum-Limited Parametric Amplifier |
title_sort | magnetic field resilient quantum limited parametric amplifier |
url | http://doi.org/10.1103/PRXQuantum.4.010322 |
work_keys_str_mv | AT mingruixu magneticfieldresilientquantumlimitedparametricamplifier AT rishengcheng magneticfieldresilientquantumlimitedparametricamplifier AT yufengwu magneticfieldresilientquantumlimitedparametricamplifier AT gangqiangliu magneticfieldresilientquantumlimitedparametricamplifier AT hongxtang magneticfieldresilientquantumlimitedparametricamplifier |