Magnetic Field-Resilient Quantum-Limited Parametric Amplifier

Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields...

Full description

Bibliographic Details
Main Authors: Mingrui Xu, Risheng Cheng, Yufeng Wu, Gangqiang Liu, Hong X. Tang
Format: Article
Language:English
Published: American Physical Society 2023-02-01
Series:PRX Quantum
Online Access:http://doi.org/10.1103/PRXQuantum.4.010322
_version_ 1811163377191354368
author Mingrui Xu
Risheng Cheng
Yufeng Wu
Gangqiang Liu
Hong X. Tang
author_facet Mingrui Xu
Risheng Cheng
Yufeng Wu
Gangqiang Liu
Hong X. Tang
author_sort Mingrui Xu
collection DOAJ
description Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spin-ensemble quantum memories. To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB. The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59±0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta. Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment. This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions.
first_indexed 2024-04-10T06:44:03Z
format Article
id doaj.art-77ddc14f906d4153a915752e08afbc63
institution Directory Open Access Journal
issn 2691-3399
language English
last_indexed 2024-04-10T06:44:03Z
publishDate 2023-02-01
publisher American Physical Society
record_format Article
series PRX Quantum
spelling doaj.art-77ddc14f906d4153a915752e08afbc632023-02-28T15:14:29ZengAmerican Physical SocietyPRX Quantum2691-33992023-02-014101032210.1103/PRXQuantum.4.010322Magnetic Field-Resilient Quantum-Limited Parametric AmplifierMingrui XuRisheng ChengYufeng WuGangqiang LiuHong X. TangSuperconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout. The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields. Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spin-ensemble quantum memories. To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB. The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59±0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta. Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment. This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions.http://doi.org/10.1103/PRXQuantum.4.010322
spellingShingle Mingrui Xu
Risheng Cheng
Yufeng Wu
Gangqiang Liu
Hong X. Tang
Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
PRX Quantum
title Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
title_full Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
title_fullStr Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
title_full_unstemmed Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
title_short Magnetic Field-Resilient Quantum-Limited Parametric Amplifier
title_sort magnetic field resilient quantum limited parametric amplifier
url http://doi.org/10.1103/PRXQuantum.4.010322
work_keys_str_mv AT mingruixu magneticfieldresilientquantumlimitedparametricamplifier
AT rishengcheng magneticfieldresilientquantumlimitedparametricamplifier
AT yufengwu magneticfieldresilientquantumlimitedparametricamplifier
AT gangqiangliu magneticfieldresilientquantumlimitedparametricamplifier
AT hongxtang magneticfieldresilientquantumlimitedparametricamplifier