Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment

The real-time artery diameter waveform assessment during cardio cycle can allow the measurement of beat-to-beat pressure change and the long-term blood pressure monitoring. The aim of this study is to develop a self-calibrated bio-impedance-based sensor, which can provide regular measurement of the...

Full description

Bibliographic Details
Main Authors: Mugeb Al-harosh, Marat Yangirov, Dmitry Kolesnikov, Sergey Shchukin
Format: Article
Language:English
Published: MDPI AG 2021-12-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/24/8438
_version_ 1797500781066190848
author Mugeb Al-harosh
Marat Yangirov
Dmitry Kolesnikov
Sergey Shchukin
author_facet Mugeb Al-harosh
Marat Yangirov
Dmitry Kolesnikov
Sergey Shchukin
author_sort Mugeb Al-harosh
collection DOAJ
description The real-time artery diameter waveform assessment during cardio cycle can allow the measurement of beat-to-beat pressure change and the long-term blood pressure monitoring. The aim of this study is to develop a self-calibrated bio-impedance-based sensor, which can provide regular measurement of the blood-pressure-dependence time variable parameters such as the artery diameter waveform and the elasticity. This paper proposes an algorithm based on analytical models which need prior geometrical and physiological patient parameters for more appropriate electrode system selection and hence location to provide accurate blood pressure measurement. As a result of this study, the red cell orientation effect contribution was estimated and removed from the bio-impedance signal obtained from the artery to keep monitoring the diameter waveform correspondence to the change of blood pressure.
first_indexed 2024-03-10T03:08:46Z
format Article
id doaj.art-77ff136234a345debaf4fe627f9d2e2e
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T03:08:46Z
publishDate 2021-12-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-77ff136234a345debaf4fe627f9d2e2e2023-11-23T10:31:39ZengMDPI AGSensors1424-82202021-12-012124843810.3390/s21248438Bio-Impedance Sensor for Real-Time Artery Diameter Waveform AssessmentMugeb Al-harosh0Marat Yangirov1Dmitry Kolesnikov2Sergey Shchukin3Department of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, RussiaDepartment of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, RussiaDepartment of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, RussiaDepartment of Medical and Technical Information Technology, Bauman Moscow State Technical University, 105005 Moscow, RussiaThe real-time artery diameter waveform assessment during cardio cycle can allow the measurement of beat-to-beat pressure change and the long-term blood pressure monitoring. The aim of this study is to develop a self-calibrated bio-impedance-based sensor, which can provide regular measurement of the blood-pressure-dependence time variable parameters such as the artery diameter waveform and the elasticity. This paper proposes an algorithm based on analytical models which need prior geometrical and physiological patient parameters for more appropriate electrode system selection and hence location to provide accurate blood pressure measurement. As a result of this study, the red cell orientation effect contribution was estimated and removed from the bio-impedance signal obtained from the artery to keep monitoring the diameter waveform correspondence to the change of blood pressure.https://www.mdpi.com/1424-8220/21/24/8438artery diameter waveformred cell orientation effectblood pressurebio-impedance
spellingShingle Mugeb Al-harosh
Marat Yangirov
Dmitry Kolesnikov
Sergey Shchukin
Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
Sensors
artery diameter waveform
red cell orientation effect
blood pressure
bio-impedance
title Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
title_full Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
title_fullStr Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
title_full_unstemmed Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
title_short Bio-Impedance Sensor for Real-Time Artery Diameter Waveform Assessment
title_sort bio impedance sensor for real time artery diameter waveform assessment
topic artery diameter waveform
red cell orientation effect
blood pressure
bio-impedance
url https://www.mdpi.com/1424-8220/21/24/8438
work_keys_str_mv AT mugebalharosh bioimpedancesensorforrealtimearterydiameterwaveformassessment
AT maratyangirov bioimpedancesensorforrealtimearterydiameterwaveformassessment
AT dmitrykolesnikov bioimpedancesensorforrealtimearterydiameterwaveformassessment
AT sergeyshchukin bioimpedancesensorforrealtimearterydiameterwaveformassessment