Water permeability of the polymer screen with a system of slits of hydraulic structures
The calculation of water permeability through a system of defects (long narrow slits in the junctions) in the screen is considered based on the filtration model. Its structural layout and description of the model main elements are given. The solution is carried out for the plane formulation of the p...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peter the Great St. Petersburg Polytechnic University
2018-11-01
|
Series: | Инженерно-строительный журнал |
Subjects: | |
Online Access: | https://engstroy.spbstu.ru/en/article/2018.83.14/ |
_version_ | 1818648668538929152 |
---|---|
author | Yuri Kosichenko Oleg Baev |
author_facet | Yuri Kosichenko Oleg Baev |
author_sort | Yuri Kosichenko |
collection | DOAJ |
description | The calculation of water permeability through a system of defects (long narrow slits in the junctions) in the screen is considered based on the filtration model. Its structural layout and description of the model main elements are given. The solution is carried out for the plane formulation of the problem by the methods of the filtration theory using the method of conformal mappings and the velocity hodograph method. A distinctive feature is the study of free filtration through a system of screen slits (the isolated standard fragment with a single defect), characterized by a pressure movement of the filtration flow in the protective layer and pressure/pressure-free movement at the bottom of the screen, taking into account the mutual influence of the slits on each other. We obtained the calculated dependences for the determination of the specific filtration flow through the screen slit, as well as the total flow through the system of slits and the averaged screen filtration factor, the results of the calculations are compared to the known formulas for the defect system. For practical use, a table of averaged screen filtration factors and a graph of the change in the reduced flow rate through the screen, considering and not considering the influence of the underlying base are made. |
first_indexed | 2024-12-17T01:22:05Z |
format | Article |
id | doaj.art-78073785a0e94010877fe1f473f15c06 |
institution | Directory Open Access Journal |
issn | 2071-0305 |
language | English |
last_indexed | 2024-12-17T01:22:05Z |
publishDate | 2018-11-01 |
publisher | Peter the Great St. Petersburg Polytechnic University |
record_format | Article |
series | Инженерно-строительный журнал |
spelling | doaj.art-78073785a0e94010877fe1f473f15c062022-12-21T22:08:47ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-03052018-11-0183714816410.18720/MCE.83.14Water permeability of the polymer screen with a system of slits of hydraulic structuresYuri Kosichenko0Oleg Baev1Russian Scientific Research Institute of Land Improvement ProblemsRussian Scientific Research Institute of Land Improvement ProblemsThe calculation of water permeability through a system of defects (long narrow slits in the junctions) in the screen is considered based on the filtration model. Its structural layout and description of the model main elements are given. The solution is carried out for the plane formulation of the problem by the methods of the filtration theory using the method of conformal mappings and the velocity hodograph method. A distinctive feature is the study of free filtration through a system of screen slits (the isolated standard fragment with a single defect), characterized by a pressure movement of the filtration flow in the protective layer and pressure/pressure-free movement at the bottom of the screen, taking into account the mutual influence of the slits on each other. We obtained the calculated dependences for the determination of the specific filtration flow through the screen slit, as well as the total flow through the system of slits and the averaged screen filtration factor, the results of the calculations are compared to the known formulas for the defect system. For practical use, a table of averaged screen filtration factors and a graph of the change in the reduced flow rate through the screen, considering and not considering the influence of the underlying base are made.https://engstroy.spbstu.ru/en/article/2018.83.14/water permeabilitypolymer screenfiltration theoryconformal mappingvelocity hodographirrigation |
spellingShingle | Yuri Kosichenko Oleg Baev Water permeability of the polymer screen with a system of slits of hydraulic structures Инженерно-строительный журнал water permeability polymer screen filtration theory conformal mapping velocity hodograph irrigation |
title | Water permeability of the polymer screen with a system of slits of hydraulic structures |
title_full | Water permeability of the polymer screen with a system of slits of hydraulic structures |
title_fullStr | Water permeability of the polymer screen with a system of slits of hydraulic structures |
title_full_unstemmed | Water permeability of the polymer screen with a system of slits of hydraulic structures |
title_short | Water permeability of the polymer screen with a system of slits of hydraulic structures |
title_sort | water permeability of the polymer screen with a system of slits of hydraulic structures |
topic | water permeability polymer screen filtration theory conformal mapping velocity hodograph irrigation |
url | https://engstroy.spbstu.ru/en/article/2018.83.14/ |
work_keys_str_mv | AT yurikosichenko waterpermeabilityofthepolymerscreenwithasystemofslitsofhydraulicstructures AT olegbaev waterpermeabilityofthepolymerscreenwithasystemofslitsofhydraulicstructures |