A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants
The flow of electric power requires overhead insulators to maintain a safe distance between charged conductors and supporting structures. These insulators are installed in outdoor locations and are hence subjected to a variety of adverse environmental conditions, such as airborne dust and other cont...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mehran University of Engineering and Technology
2023-09-01
|
Series: | Mehran University Research Journal of Engineering and Technology |
Online Access: | https://publications.muet.edu.pk/index.php/muetrj/article/view/2674 |
_version_ | 1797664546067841024 |
---|---|
author | Umer Ijaz Muhammad Fraz Anwar Muhammad Nadeem Muhammad Farhan Kashif Nisar Paracha Muhammad Saad Sharif |
author_facet | Umer Ijaz Muhammad Fraz Anwar Muhammad Nadeem Muhammad Farhan Kashif Nisar Paracha Muhammad Saad Sharif |
author_sort | Umer Ijaz |
collection | DOAJ |
description | The flow of electric power requires overhead insulators to maintain a safe distance between charged conductors and supporting structures. These insulators are installed in outdoor locations and are hence subjected to a variety of adverse environmental conditions, such as airborne dust and other contaminants. In moist conditions, these pollution factors can cause flashover, resulting in the loss of energy in the form of heat and light. Therefore, it is crucial to determine various types of contaminants based on geographical conditions and analyze their effects on the insulation capabilities of these insulators. This research work analyzes the accumulation of certain contaminants on the insulators installed at various geographical locations. Experimental approaches for detecting the level of contamination of insulators have also been examined, along with their limitations. Moreover, the findings of pollution tests performed in industrial, coastal, desert, inland, agricultural, and biological areas are presented as well. The flash-over voltage (FOV) of disc insulators made of porcelain for various pH and conductivity values has been observed to correlate FOV with pH and conductivity values of the pollutants. The pH and conductivity of contaminants are crucial factors impacting the insulator's flashover voltage, which is influenced by surrounding atmospheric conditions. Understanding the composition and monitoring these parameters can aid in developing preventive maintenance programs based on specified pH values, ensuring the reliability and performance of overhead insulators. |
first_indexed | 2024-03-11T19:31:53Z |
format | Article |
id | doaj.art-784f7b8a1a394dffbe5a503647ebc599 |
institution | Directory Open Access Journal |
issn | 0254-7821 2413-7219 |
language | English |
last_indexed | 2024-03-11T19:31:53Z |
publishDate | 2023-09-01 |
publisher | Mehran University of Engineering and Technology |
record_format | Article |
series | Mehran University Research Journal of Engineering and Technology |
spelling | doaj.art-784f7b8a1a394dffbe5a503647ebc5992023-10-06T13:16:52ZengMehran University of Engineering and TechnologyMehran University Research Journal of Engineering and Technology0254-78212413-72192023-09-01424647110.22581/muet1982.2304.26742674A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminantsUmer Ijaz0Muhammad Fraz Anwar1Muhammad Nadeem2Muhammad Farhan3Kashif Nisar Paracha4Muhammad Saad Sharif5Department of Electrical Engineering and Technology, Government College University Faisalabad PakistanDepartment of Electrical Engineering and Technology, Government College University Faisalabad PakistanDepartment of Electrical Engineering and Technology, Government College University Faisalabad PakistanDepartment of Electrical Engineering and Technology, Government College University Faisalabad PakistanDepartment of Electrical Engineering and Technology, Government College University Faisalabad PakistanDepartment of Electrical Engineering and Technology, Government College University Faisalabad PakistanThe flow of electric power requires overhead insulators to maintain a safe distance between charged conductors and supporting structures. These insulators are installed in outdoor locations and are hence subjected to a variety of adverse environmental conditions, such as airborne dust and other contaminants. In moist conditions, these pollution factors can cause flashover, resulting in the loss of energy in the form of heat and light. Therefore, it is crucial to determine various types of contaminants based on geographical conditions and analyze their effects on the insulation capabilities of these insulators. This research work analyzes the accumulation of certain contaminants on the insulators installed at various geographical locations. Experimental approaches for detecting the level of contamination of insulators have also been examined, along with their limitations. Moreover, the findings of pollution tests performed in industrial, coastal, desert, inland, agricultural, and biological areas are presented as well. The flash-over voltage (FOV) of disc insulators made of porcelain for various pH and conductivity values has been observed to correlate FOV with pH and conductivity values of the pollutants. The pH and conductivity of contaminants are crucial factors impacting the insulator's flashover voltage, which is influenced by surrounding atmospheric conditions. Understanding the composition and monitoring these parameters can aid in developing preventive maintenance programs based on specified pH values, ensuring the reliability and performance of overhead insulators.https://publications.muet.edu.pk/index.php/muetrj/article/view/2674 |
spellingShingle | Umer Ijaz Muhammad Fraz Anwar Muhammad Nadeem Muhammad Farhan Kashif Nisar Paracha Muhammad Saad Sharif A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants Mehran University Research Journal of Engineering and Technology |
title | A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants |
title_full | A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants |
title_fullStr | A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants |
title_full_unstemmed | A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants |
title_short | A critical study on detection of pollution level of overhead insulators by measuring pH and conductivity of the contaminants |
title_sort | critical study on detection of pollution level of overhead insulators by measuring ph and conductivity of the contaminants |
url | https://publications.muet.edu.pk/index.php/muetrj/article/view/2674 |
work_keys_str_mv | AT umerijaz acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadfrazanwar acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadnadeem acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadfarhan acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT kashifnisarparacha acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadsaadsharif acriticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT umerijaz criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadfrazanwar criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadnadeem criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadfarhan criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT kashifnisarparacha criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants AT muhammadsaadsharif criticalstudyondetectionofpollutionlevelofoverheadinsulatorsbymeasuringphandconductivityofthecontaminants |