Pilot protection of flexible DC line based on Jaccard similarity integration criterion

The flexible DC line protection based on the double-ended method with large communication and long action time is greatly affected by factors such as noise, which makes it difficult to set. Based on this, a pilot protection method of flexible DC line based on Jaccard similarity integration criterion...

Full description

Bibliographic Details
Main Authors: LI Zhenxing, SHE Shuangxi, XU Hao, CUI Xiaolin, LI Zhenhua, ZHANG Mengmeng
Format: Article
Language:zho
Published: Editorial Department of Electric Power Engineering Technology 2023-03-01
Series:电力工程技术
Subjects:
Online Access:https://www.epet-info.com/dlgcjsen/article/abstract/220517703
_version_ 1827978558997266432
author LI Zhenxing
SHE Shuangxi
XU Hao
CUI Xiaolin
LI Zhenhua
ZHANG Mengmeng
author_facet LI Zhenxing
SHE Shuangxi
XU Hao
CUI Xiaolin
LI Zhenhua
ZHANG Mengmeng
author_sort LI Zhenxing
collection DOAJ
description The flexible DC line protection based on the double-ended method with large communication and long action time is greatly affected by factors such as noise, which makes it difficult to set. Based on this, a pilot protection method of flexible DC line based on Jaccard similarity integration criterion is proposed. Firstly, the fault characteristics of voltage and current change rate in the case of internal and external faults of flexible DC lines are analyzed, and the conversion relationship between analog quantities and logical quantities is constructed respectively. Then a Jaccard similarity model based on the comparison of logical quantities under the 0.5 ms data window is proposed. The integrated criterion is constructed with high similarity to realize fault type identification, and fault starting and fault pole selection criteria are not required. Finally, the double-ended longitudinal protection scheme based on the comparison of logical quantities realizes the rapid protection of the flexible DC line. The scheme is easy to be implemented, because the protection principle of that is simple with fast action speed. Using the four-terminal flexible straight model built by PSCAD/EMTDC, the protection effectiveness in various scenarios such as different fault types, high-resistance grounding, and noise interference inside and outside the zone were verified.
first_indexed 2024-04-09T21:22:47Z
format Article
id doaj.art-78829498a1e6433e8078e54148b77e02
institution Directory Open Access Journal
issn 2096-3203
language zho
last_indexed 2024-04-09T21:22:47Z
publishDate 2023-03-01
publisher Editorial Department of Electric Power Engineering Technology
record_format Article
series 电力工程技术
spelling doaj.art-78829498a1e6433e8078e54148b77e022023-03-28T03:31:10ZzhoEditorial Department of Electric Power Engineering Technology电力工程技术2096-32032023-03-014229410210.12158/j.2096-3203.2023.02.011220517703Pilot protection of flexible DC line based on Jaccard similarity integration criterionLI Zhenxing0SHE Shuangxi1XU Hao2CUI Xiaolin3LI Zhenhua4ZHANG Mengmeng5Hubei Provincial Engineering Technology Research Center for Power Transmission Line (China Three Gorges University), Yichang 443002, ChinaCollege of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, ChinaEHV Company of State Grid Hubei Electric Power Co., Ltd., Wuhan 430050, ChinaCollege of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, ChinaHubei Provincial Engineering Technology Research Center for Power Transmission Line (China Three Gorges University), Yichang 443002, ChinaCollege of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443002, ChinaThe flexible DC line protection based on the double-ended method with large communication and long action time is greatly affected by factors such as noise, which makes it difficult to set. Based on this, a pilot protection method of flexible DC line based on Jaccard similarity integration criterion is proposed. Firstly, the fault characteristics of voltage and current change rate in the case of internal and external faults of flexible DC lines are analyzed, and the conversion relationship between analog quantities and logical quantities is constructed respectively. Then a Jaccard similarity model based on the comparison of logical quantities under the 0.5 ms data window is proposed. The integrated criterion is constructed with high similarity to realize fault type identification, and fault starting and fault pole selection criteria are not required. Finally, the double-ended longitudinal protection scheme based on the comparison of logical quantities realizes the rapid protection of the flexible DC line. The scheme is easy to be implemented, because the protection principle of that is simple with fast action speed. Using the four-terminal flexible straight model built by PSCAD/EMTDC, the protection effectiveness in various scenarios such as different fault types, high-resistance grounding, and noise interference inside and outside the zone were verified.https://www.epet-info.com/dlgcjsen/article/abstract/220517703four-terminal flexible dc transmission systemflexible dc linejaccard similarityintegration criterionpilot protectionfault type identification
spellingShingle LI Zhenxing
SHE Shuangxi
XU Hao
CUI Xiaolin
LI Zhenhua
ZHANG Mengmeng
Pilot protection of flexible DC line based on Jaccard similarity integration criterion
电力工程技术
four-terminal flexible dc transmission system
flexible dc line
jaccard similarity
integration criterion
pilot protection
fault type identification
title Pilot protection of flexible DC line based on Jaccard similarity integration criterion
title_full Pilot protection of flexible DC line based on Jaccard similarity integration criterion
title_fullStr Pilot protection of flexible DC line based on Jaccard similarity integration criterion
title_full_unstemmed Pilot protection of flexible DC line based on Jaccard similarity integration criterion
title_short Pilot protection of flexible DC line based on Jaccard similarity integration criterion
title_sort pilot protection of flexible dc line based on jaccard similarity integration criterion
topic four-terminal flexible dc transmission system
flexible dc line
jaccard similarity
integration criterion
pilot protection
fault type identification
url https://www.epet-info.com/dlgcjsen/article/abstract/220517703
work_keys_str_mv AT lizhenxing pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion
AT sheshuangxi pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion
AT xuhao pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion
AT cuixiaolin pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion
AT lizhenhua pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion
AT zhangmengmeng pilotprotectionofflexibledclinebasedonjaccardsimilarityintegrationcriterion