8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study

Thomas W Samuelson,1 Tanner J Ferguson,2 Nathan M Radcliffe,3 Richard Lewis,4 Justin Schweitzer,5 Russell Swan,5 John P Berdahl5 1Minnesota Eye Consultants, Minneapolis, MN, USA; 2Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA; 3Department of Ophthalmology, New York Eye and Ear Infirmary o...

Full description

Bibliographic Details
Main Authors: Samuelson TW, Ferguson TJ, Radcliffe NM, Lewis R, Schweitzer J, Swan R, Berdahl JP
Format: Article
Language:English
Published: Dove Medical Press 2019-10-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/8-hrs-safety-evaluation-of-a-multi-pressure-dial-in-eyes-with-glaucoma-peer-reviewed-article-OPTH
_version_ 1831666927869624320
author Samuelson TW
Ferguson TJ
Radcliffe NM
Lewis R
Schweitzer J
Swan R
Berdahl JP
author_facet Samuelson TW
Ferguson TJ
Radcliffe NM
Lewis R
Schweitzer J
Swan R
Berdahl JP
author_sort Samuelson TW
collection DOAJ
description Thomas W Samuelson,1 Tanner J Ferguson,2 Nathan M Radcliffe,3 Richard Lewis,4 Justin Schweitzer,5 Russell Swan,5 John P Berdahl5 1Minnesota Eye Consultants, Minneapolis, MN, USA; 2Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA; 3Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, NY, USA; 4Sacramento Eye Consultants, Sacramento, CA, USA; 5Vance Thompson Vision, Sioux Falls, SD, USACorrespondence: Tanner J FergusonCole Eye Institute, Cleveland Clinic, Cleveland OH, USAEmail tannerferg@gmail.comPurpose: To investigate the safety and tolerability of the multi-pressure dial with a continuous 8-hr duration in subjects with open-angle glaucoma.Design: Prospective, controlled open-label, randomized, single site study.Subjects: Twenty eyes of 10 subjects with open-angle glaucoma were fitted with a multi-pressure dial and randomized to negative pressure application of −10 mmHg in one eye for 8 (continuous) hours and ambient atmospheric pressure in the contralateral eye.Methods: Main safety outcome measures include best-corrected visual acuity (BCVA), intraocular pressure (IOP) changes from baseline after negative pressure application, slit lamp and dilated fundus exam findings, and rate of adverse events. Subjective assessments were administered both hourly during the 8-hr study period and immediately following the study period.Results: There were no statistically significant changes in IOP, BCVA or TBUT immediately following the 8-hr study period or at the 1-week follow-up visit. Patient-reported tolerability was favorable with a mean response of 1.8 ± 0.4 (scale → 1=best, 10 = worst). Subjects also reported positive interest in the MPD as a glaucoma therapy with a mean response of 1.8 ± 0.5 (scale → 1=best, 10 = worst). One adverse event was reported (headache) and resolved at conclusion of the Day 0 visit.Conclusion: The MPD demonstrated favorable safety with key parameters remaining stable after an 8-hr wear with negative pressure. Negative pressure application through the MPD was well tolerated by subjects enrolled in the study. The favorable findings demonstrate the safety of sustained delivery of negative pressure over a continuous, uninterrupted 8-hr duration.Keywords: multi-pressure dial, normal-tension glaucoma, open-angle glaucoma, glaucoma treatment
first_indexed 2024-12-19T20:01:34Z
format Article
id doaj.art-78c1a52b083a4c04a6ca84d5726b41de
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-19T20:01:34Z
publishDate 2019-10-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-78c1a52b083a4c04a6ca84d5726b41de2022-12-21T20:07:39ZengDove Medical PressClinical Ophthalmology1177-54832019-10-01Volume 1319471953489158 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized StudySamuelson TWFerguson TJRadcliffe NMLewis RSchweitzer JSwan RBerdahl JPThomas W Samuelson,1 Tanner J Ferguson,2 Nathan M Radcliffe,3 Richard Lewis,4 Justin Schweitzer,5 Russell Swan,5 John P Berdahl5 1Minnesota Eye Consultants, Minneapolis, MN, USA; 2Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA; 3Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, NY, USA; 4Sacramento Eye Consultants, Sacramento, CA, USA; 5Vance Thompson Vision, Sioux Falls, SD, USACorrespondence: Tanner J FergusonCole Eye Institute, Cleveland Clinic, Cleveland OH, USAEmail tannerferg@gmail.comPurpose: To investigate the safety and tolerability of the multi-pressure dial with a continuous 8-hr duration in subjects with open-angle glaucoma.Design: Prospective, controlled open-label, randomized, single site study.Subjects: Twenty eyes of 10 subjects with open-angle glaucoma were fitted with a multi-pressure dial and randomized to negative pressure application of −10 mmHg in one eye for 8 (continuous) hours and ambient atmospheric pressure in the contralateral eye.Methods: Main safety outcome measures include best-corrected visual acuity (BCVA), intraocular pressure (IOP) changes from baseline after negative pressure application, slit lamp and dilated fundus exam findings, and rate of adverse events. Subjective assessments were administered both hourly during the 8-hr study period and immediately following the study period.Results: There were no statistically significant changes in IOP, BCVA or TBUT immediately following the 8-hr study period or at the 1-week follow-up visit. Patient-reported tolerability was favorable with a mean response of 1.8 ± 0.4 (scale → 1=best, 10 = worst). Subjects also reported positive interest in the MPD as a glaucoma therapy with a mean response of 1.8 ± 0.5 (scale → 1=best, 10 = worst). One adverse event was reported (headache) and resolved at conclusion of the Day 0 visit.Conclusion: The MPD demonstrated favorable safety with key parameters remaining stable after an 8-hr wear with negative pressure. Negative pressure application through the MPD was well tolerated by subjects enrolled in the study. The favorable findings demonstrate the safety of sustained delivery of negative pressure over a continuous, uninterrupted 8-hr duration.Keywords: multi-pressure dial, normal-tension glaucoma, open-angle glaucoma, glaucoma treatmenthttps://www.dovepress.com/8-hrs-safety-evaluation-of-a-multi-pressure-dial-in-eyes-with-glaucoma-peer-reviewed-article-OPTHmulti-pressure dialnormal-tension glaucomaopen-angle glaucomaglaucoma treatment
spellingShingle Samuelson TW
Ferguson TJ
Radcliffe NM
Lewis R
Schweitzer J
Swan R
Berdahl JP
8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
Clinical Ophthalmology
multi-pressure dial
normal-tension glaucoma
open-angle glaucoma
glaucoma treatment
title 8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
title_full 8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
title_fullStr 8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
title_full_unstemmed 8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
title_short 8 hrs Safety Evaluation Of A Multi-Pressure Dial In Eyes With Glaucoma: Prospective, Open-Label, Randomized Study
title_sort 8 hrs safety evaluation of a multi pressure dial in eyes with glaucoma prospective open label randomized study
topic multi-pressure dial
normal-tension glaucoma
open-angle glaucoma
glaucoma treatment
url https://www.dovepress.com/8-hrs-safety-evaluation-of-a-multi-pressure-dial-in-eyes-with-glaucoma-peer-reviewed-article-OPTH
work_keys_str_mv AT samuelsontw 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT fergusontj 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT radcliffenm 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT lewisr 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT schweitzerj 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT swanr 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy
AT berdahljp 8hrssafetyevaluationofamultipressuredialineyeswithglaucomaprospectiveopenlabelrandomizedstudy