Comparison of keratometry versions in patients with corneal astigmatism

Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given t...

Full description

Bibliographic Details
Main Authors: A. N. Kulikov, E. V. Danilenko, E. Yu. Kozhevnikov
Format: Article
Language:Russian
Published: Real Time Ltd 2022-06-01
Series:Российский офтальмологический журнал
Subjects:
Online Access:https://roj.igb.ru/jour/article/view/965
_version_ 1797878294170828800
author A. N. Kulikov
E. V. Danilenko
E. Yu. Kozhevnikov
author_facet A. N. Kulikov
E. V. Danilenko
E. Yu. Kozhevnikov
author_sort A. N. Kulikov
collection DOAJ
description Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given three biometry tests using IOL Master 500, Lenstar LS 900, IOL Master 700, Pentacam and Galilei G6.Results. The data were divided into groups depending on the principle of mathematical modeling of the corneal surface: group I involved the material processed by IOL Master 500, Lenstar LS 900, IOL Master 700; group II contained maps of the anterior corneal surface; and group III, those of the posterior surface. In group I, Lenstar showed the highest values of keratometry. In group II, the values of K1 , Kave in the 6 mm area were lower than in the pupil diameter area and than any values of K in the 4 mm area; the lowest values of K in this area were obtained on the Pentacam SimK. In group III, in the pupil diameter area (4.0–4.5 mm), all K values obtained with diverse equipment were different whilst in the 6 mm area the values differed only in the flat meridian. Astigmatism within groups I, III showed no difference while in group II the SimK data were different. The astigmatism axes obtained on IOLMaster 500 differed from the respective data provided by other devices. The devices of group I, 6 mm area, were the most stable.Conclusions. The highest values of keratometry are obtained when only the anterior surface of the cornea is taken into account, the lowest values are characteristic of the posterior surface. The stability of the parameter registered grew with the increase of the measured zone diameters. The biometers of group 1 showed the highest values of astigmatism with the maximum repeatability of the measurements
first_indexed 2024-04-10T02:30:27Z
format Article
id doaj.art-78c1d67060ab40c5ab8c3e68c19138c6
institution Directory Open Access Journal
issn 2072-0076
2587-5760
language Russian
last_indexed 2024-04-10T02:30:27Z
publishDate 2022-06-01
publisher Real Time Ltd
record_format Article
series Российский офтальмологический журнал
spelling doaj.art-78c1d67060ab40c5ab8c3e68c19138c62023-03-13T07:54:32ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602022-06-01152 (Прил)849210.21516/2072-0076-2022-15-2-supplement-84-92454Comparison of keratometry versions in patients with corneal astigmatismA. N. Kulikov0E. V. Danilenko1E. Yu. Kozhevnikov2ФГБВОУ ВО «Военно-медицинская академия им. С.М. Кирова» МО РФФГБВОУ ВО «Военно-медицинская академия им. С.М. Кирова» МО РФФГБВОУ ВО «Военно-медицинская академия им. С.М. Кирова» МО РФPurpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given three biometry tests using IOL Master 500, Lenstar LS 900, IOL Master 700, Pentacam and Galilei G6.Results. The data were divided into groups depending on the principle of mathematical modeling of the corneal surface: group I involved the material processed by IOL Master 500, Lenstar LS 900, IOL Master 700; group II contained maps of the anterior corneal surface; and group III, those of the posterior surface. In group I, Lenstar showed the highest values of keratometry. In group II, the values of K1 , Kave in the 6 mm area were lower than in the pupil diameter area and than any values of K in the 4 mm area; the lowest values of K in this area were obtained on the Pentacam SimK. In group III, in the pupil diameter area (4.0–4.5 mm), all K values obtained with diverse equipment were different whilst in the 6 mm area the values differed only in the flat meridian. Astigmatism within groups I, III showed no difference while in group II the SimK data were different. The astigmatism axes obtained on IOLMaster 500 differed from the respective data provided by other devices. The devices of group I, 6 mm area, were the most stable.Conclusions. The highest values of keratometry are obtained when only the anterior surface of the cornea is taken into account, the lowest values are characteristic of the posterior surface. The stability of the parameter registered grew with the increase of the measured zone diameters. The biometers of group 1 showed the highest values of astigmatism with the maximum repeatability of the measurementshttps://roj.igb.ru/jour/article/view/965кератотопографиякератометрияроговичный астигматизмiol master 500lenstar ls 900iol master 700pentacamgalilei g6
spellingShingle A. N. Kulikov
E. V. Danilenko
E. Yu. Kozhevnikov
Comparison of keratometry versions in patients with corneal astigmatism
Российский офтальмологический журнал
кератотопография
кератометрия
роговичный астигматизм
iol master 500
lenstar ls 900
iol master 700
pentacam
galilei g6
title Comparison of keratometry versions in patients with corneal astigmatism
title_full Comparison of keratometry versions in patients with corneal astigmatism
title_fullStr Comparison of keratometry versions in patients with corneal astigmatism
title_full_unstemmed Comparison of keratometry versions in patients with corneal astigmatism
title_short Comparison of keratometry versions in patients with corneal astigmatism
title_sort comparison of keratometry versions in patients with corneal astigmatism
topic кератотопография
кератометрия
роговичный астигматизм
iol master 500
lenstar ls 900
iol master 700
pentacam
galilei g6
url https://roj.igb.ru/jour/article/view/965
work_keys_str_mv AT ankulikov comparisonofkeratometryversionsinpatientswithcornealastigmatism
AT evdanilenko comparisonofkeratometryversionsinpatientswithcornealastigmatism
AT eyukozhevnikov comparisonofkeratometryversionsinpatientswithcornealastigmatism