Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce

In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanit...

Full description

Bibliographic Details
Main Authors: Yeting Sun, Zhaoxia Wu, Yangyang Zhang, Jiayi Wang
Format: Article
Language:English
Published: Elsevier 2022-02-01
Series:Ultrasonics Sonochemistry
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1350417722000244
_version_ 1798025160562835456
author Yeting Sun
Zhaoxia Wu
Yangyang Zhang
Jiayi Wang
author_facet Yeting Sun
Zhaoxia Wu
Yangyang Zhang
Jiayi Wang
author_sort Yeting Sun
collection DOAJ
description In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanitizer residues on the surface of disinfected fresh-cut vegetables. In this study, aqueous ozone (AO), a low-cost and residue-free sanitizer, was used to replace TW rinsing in combination with US (28 kHz)–chlorine (free chlorine [FC] at 10 ppm, a concentration recommended for industrial use) for the disinfection of fresh-cut lettuce as a model. US–chlorine (40 s) + 2.0 ppm AO (60 s) treatment resulted in browning spots on lettuce surface at the end of storage. In contrast, US–chlorine (40 s) + 1.0 ppm AO (60 s) did not lead to deterioration of the sensory quality (sensory crispness, color, and flavor) and a change in total color difference, and the activities of browning-related enzymes were significantly lower. Moreover, US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment led to significantly lower counts of Escherichia coli O157:H7, Salmonella Typhimurium, aerobic mesophilic (AMC), and molds and yeasts (M&Y) on days 0–7 than US–chlorine (60 s) + TW (60 s) and single 1.0 ppm AO (120 s) treatments, suggesting that AO provided an additional disinfection effect over TW, while reducing the overall processing time by 20 s. Cell membrane permeability analysis (alkaline phosphatase, protein, nucleotide, and adenosine triphosphate leakage) showed that the combination with 1.0 ppm AO caused more severe cell membrane damage in E. coli O157:H7 and S. Typhimurium, explaining the higher disinfection efficacy. 16S rRNA sequencing revealed that following US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment, Massilia and Acinetobacter had higher relative abundances (RAs) on day 7 than after US–chlorine (60 s) + TW (60 s) treatment, whereas the RAs of Escherichia–Shigella was significantly lower, indicating that the former treatment has a superior capacity in maintaining a stable microbial composition. This explains from an ecological point of view why US–chlorine (40 s) + 1.0 ppm of AO (60 s) led to the lowest AMC and M&Y counts during storage. The study results provide evidence that AO has potential as an alternative to TW rinsing to increase the disinfection efficacy of US–chlorine.
first_indexed 2024-04-11T18:15:18Z
format Article
id doaj.art-790bd9b8d11841f69ea6b7739ea88282
institution Directory Open Access Journal
issn 1350-4177
language English
last_indexed 2024-04-11T18:15:18Z
publishDate 2022-02-01
publisher Elsevier
record_format Article
series Ultrasonics Sonochemistry
spelling doaj.art-790bd9b8d11841f69ea6b7739ea882822022-12-22T04:09:57ZengElsevierUltrasonics Sonochemistry1350-41772022-02-0183105931Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produceYeting Sun0Zhaoxia Wu1Yangyang Zhang2Jiayi Wang3Beijing Vegetable Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, ChinaCollege of Food Science, Shenyang Agricultural University, Shenyang 110000, ChinaCollege of Food and Chemical Engineering, Shaoyang University, Shaoyang 422000, ChinaCollege of Food and Chemical Engineering, Shaoyang University, Shaoyang 422000, China; Corresponding author.In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanitizer residues on the surface of disinfected fresh-cut vegetables. In this study, aqueous ozone (AO), a low-cost and residue-free sanitizer, was used to replace TW rinsing in combination with US (28 kHz)–chlorine (free chlorine [FC] at 10 ppm, a concentration recommended for industrial use) for the disinfection of fresh-cut lettuce as a model. US–chlorine (40 s) + 2.0 ppm AO (60 s) treatment resulted in browning spots on lettuce surface at the end of storage. In contrast, US–chlorine (40 s) + 1.0 ppm AO (60 s) did not lead to deterioration of the sensory quality (sensory crispness, color, and flavor) and a change in total color difference, and the activities of browning-related enzymes were significantly lower. Moreover, US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment led to significantly lower counts of Escherichia coli O157:H7, Salmonella Typhimurium, aerobic mesophilic (AMC), and molds and yeasts (M&Y) on days 0–7 than US–chlorine (60 s) + TW (60 s) and single 1.0 ppm AO (120 s) treatments, suggesting that AO provided an additional disinfection effect over TW, while reducing the overall processing time by 20 s. Cell membrane permeability analysis (alkaline phosphatase, protein, nucleotide, and adenosine triphosphate leakage) showed that the combination with 1.0 ppm AO caused more severe cell membrane damage in E. coli O157:H7 and S. Typhimurium, explaining the higher disinfection efficacy. 16S rRNA sequencing revealed that following US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment, Massilia and Acinetobacter had higher relative abundances (RAs) on day 7 than after US–chlorine (60 s) + TW (60 s) treatment, whereas the RAs of Escherichia–Shigella was significantly lower, indicating that the former treatment has a superior capacity in maintaining a stable microbial composition. This explains from an ecological point of view why US–chlorine (40 s) + 1.0 ppm of AO (60 s) led to the lowest AMC and M&Y counts during storage. The study results provide evidence that AO has potential as an alternative to TW rinsing to increase the disinfection efficacy of US–chlorine.http://www.sciencedirect.com/science/article/pii/S1350417722000244UltrasonicationFree chlorineDisinfectionAqueous ozoneFresh-cut
spellingShingle Yeting Sun
Zhaoxia Wu
Yangyang Zhang
Jiayi Wang
Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
Ultrasonics Sonochemistry
Ultrasonication
Free chlorine
Disinfection
Aqueous ozone
Fresh-cut
title Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
title_full Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
title_fullStr Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
title_full_unstemmed Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
title_short Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
title_sort use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound assisted washing of fresh produce
topic Ultrasonication
Free chlorine
Disinfection
Aqueous ozone
Fresh-cut
url http://www.sciencedirect.com/science/article/pii/S1350417722000244
work_keys_str_mv AT yetingsun useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce
AT zhaoxiawu useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce
AT yangyangzhang useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce
AT jiayiwang useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce