Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce
In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanit...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2022-02-01
|
Series: | Ultrasonics Sonochemistry |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1350417722000244 |
_version_ | 1798025160562835456 |
---|---|
author | Yeting Sun Zhaoxia Wu Yangyang Zhang Jiayi Wang |
author_facet | Yeting Sun Zhaoxia Wu Yangyang Zhang Jiayi Wang |
author_sort | Yeting Sun |
collection | DOAJ |
description | In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanitizer residues on the surface of disinfected fresh-cut vegetables. In this study, aqueous ozone (AO), a low-cost and residue-free sanitizer, was used to replace TW rinsing in combination with US (28 kHz)–chlorine (free chlorine [FC] at 10 ppm, a concentration recommended for industrial use) for the disinfection of fresh-cut lettuce as a model. US–chlorine (40 s) + 2.0 ppm AO (60 s) treatment resulted in browning spots on lettuce surface at the end of storage. In contrast, US–chlorine (40 s) + 1.0 ppm AO (60 s) did not lead to deterioration of the sensory quality (sensory crispness, color, and flavor) and a change in total color difference, and the activities of browning-related enzymes were significantly lower. Moreover, US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment led to significantly lower counts of Escherichia coli O157:H7, Salmonella Typhimurium, aerobic mesophilic (AMC), and molds and yeasts (M&Y) on days 0–7 than US–chlorine (60 s) + TW (60 s) and single 1.0 ppm AO (120 s) treatments, suggesting that AO provided an additional disinfection effect over TW, while reducing the overall processing time by 20 s. Cell membrane permeability analysis (alkaline phosphatase, protein, nucleotide, and adenosine triphosphate leakage) showed that the combination with 1.0 ppm AO caused more severe cell membrane damage in E. coli O157:H7 and S. Typhimurium, explaining the higher disinfection efficacy. 16S rRNA sequencing revealed that following US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment, Massilia and Acinetobacter had higher relative abundances (RAs) on day 7 than after US–chlorine (60 s) + TW (60 s) treatment, whereas the RAs of Escherichia–Shigella was significantly lower, indicating that the former treatment has a superior capacity in maintaining a stable microbial composition. This explains from an ecological point of view why US–chlorine (40 s) + 1.0 ppm of AO (60 s) led to the lowest AMC and M&Y counts during storage. The study results provide evidence that AO has potential as an alternative to TW rinsing to increase the disinfection efficacy of US–chlorine. |
first_indexed | 2024-04-11T18:15:18Z |
format | Article |
id | doaj.art-790bd9b8d11841f69ea6b7739ea88282 |
institution | Directory Open Access Journal |
issn | 1350-4177 |
language | English |
last_indexed | 2024-04-11T18:15:18Z |
publishDate | 2022-02-01 |
publisher | Elsevier |
record_format | Article |
series | Ultrasonics Sonochemistry |
spelling | doaj.art-790bd9b8d11841f69ea6b7739ea882822022-12-22T04:09:57ZengElsevierUltrasonics Sonochemistry1350-41772022-02-0183105931Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produceYeting Sun0Zhaoxia Wu1Yangyang Zhang2Jiayi Wang3Beijing Vegetable Research Center, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, ChinaCollege of Food Science, Shenyang Agricultural University, Shenyang 110000, ChinaCollege of Food and Chemical Engineering, Shaoyang University, Shaoyang 422000, ChinaCollege of Food and Chemical Engineering, Shaoyang University, Shaoyang 422000, China; Corresponding author.In minimal processing industry, chlorine is widely used in the disinfection process and ultrasound (US) increases the disinfection efficacy of chlorine and reduces the cross-contamination incidence during washing. Tap water (TW), which has no disinfection effect, is generally used to rinse off sanitizer residues on the surface of disinfected fresh-cut vegetables. In this study, aqueous ozone (AO), a low-cost and residue-free sanitizer, was used to replace TW rinsing in combination with US (28 kHz)–chlorine (free chlorine [FC] at 10 ppm, a concentration recommended for industrial use) for the disinfection of fresh-cut lettuce as a model. US–chlorine (40 s) + 2.0 ppm AO (60 s) treatment resulted in browning spots on lettuce surface at the end of storage. In contrast, US–chlorine (40 s) + 1.0 ppm AO (60 s) did not lead to deterioration of the sensory quality (sensory crispness, color, and flavor) and a change in total color difference, and the activities of browning-related enzymes were significantly lower. Moreover, US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment led to significantly lower counts of Escherichia coli O157:H7, Salmonella Typhimurium, aerobic mesophilic (AMC), and molds and yeasts (M&Y) on days 0–7 than US–chlorine (60 s) + TW (60 s) and single 1.0 ppm AO (120 s) treatments, suggesting that AO provided an additional disinfection effect over TW, while reducing the overall processing time by 20 s. Cell membrane permeability analysis (alkaline phosphatase, protein, nucleotide, and adenosine triphosphate leakage) showed that the combination with 1.0 ppm AO caused more severe cell membrane damage in E. coli O157:H7 and S. Typhimurium, explaining the higher disinfection efficacy. 16S rRNA sequencing revealed that following US–chlorine (40 s) + 1.0 ppm of AO (60 s) treatment, Massilia and Acinetobacter had higher relative abundances (RAs) on day 7 than after US–chlorine (60 s) + TW (60 s) treatment, whereas the RAs of Escherichia–Shigella was significantly lower, indicating that the former treatment has a superior capacity in maintaining a stable microbial composition. This explains from an ecological point of view why US–chlorine (40 s) + 1.0 ppm of AO (60 s) led to the lowest AMC and M&Y counts during storage. The study results provide evidence that AO has potential as an alternative to TW rinsing to increase the disinfection efficacy of US–chlorine.http://www.sciencedirect.com/science/article/pii/S1350417722000244UltrasonicationFree chlorineDisinfectionAqueous ozoneFresh-cut |
spellingShingle | Yeting Sun Zhaoxia Wu Yangyang Zhang Jiayi Wang Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce Ultrasonics Sonochemistry Ultrasonication Free chlorine Disinfection Aqueous ozone Fresh-cut |
title | Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce |
title_full | Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce |
title_fullStr | Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce |
title_full_unstemmed | Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce |
title_short | Use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound-assisted washing of fresh produce |
title_sort | use of aqueous ozone rinsing to improve the disinfection efficacy and shorten the processing time of ultrasound assisted washing of fresh produce |
topic | Ultrasonication Free chlorine Disinfection Aqueous ozone Fresh-cut |
url | http://www.sciencedirect.com/science/article/pii/S1350417722000244 |
work_keys_str_mv | AT yetingsun useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce AT zhaoxiawu useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce AT yangyangzhang useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce AT jiayiwang useofaqueousozonerinsingtoimprovethedisinfectionefficacyandshortentheprocessingtimeofultrasoundassistedwashingoffreshproduce |