In seismic areas many buildings need to be retrofitted. In some cases, it is possible to apply carbon fiber-reinforcement polymer/plastic (CFRP), steel-jackets, and concrete jackets as rehabilitation methods. Several researches have been developed with this technology in the last years. In addition,...

Full description

Bibliographic Details
Main Author: A. Ismail
Format: Article
Language:English
Published: Taylor & Francis Group 2014-04-01
Series:HBRC Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S168740481300045X
_version_ 1819261910378348544
author A. Ismail
author_facet A. Ismail
author_sort A. Ismail
collection DOAJ
description In seismic areas many buildings need to be retrofitted. In some cases, it is possible to apply carbon fiber-reinforcement polymer/plastic (CFRP), steel-jackets, and concrete jackets as rehabilitation methods. Several researches have been developed with this technology in the last years. In addition, there are guides for the design of retrofitted systems of existing structures. However, it is necessary to count with reliable methodologies for structural analysis of these structures retrofitted. In some cases, the codes require non-linear analysis for the verification of design proposed as retrofit. In this study, an attempt has been done for investigating the seismic behavior of a typical existing building in Cairo by performing static pushover analysis before and after retrofitting the columns by either, reinforced concrete, steel sections or carbon fiber reinforced polymer (CFRP) composite jackets. The selected model building represents nearly all typical construction deficiencies of buildings constructed before recent earthquake resistant design codes. To investigate the possibility and effectiveness of the use of these systems, a comparative study was performed. A comparison was made between a typical framed RC building and the same building after retrofitting with CFRP confinement, steel elements and concrete jackets. By using nonlinear static (pushover) analysis, the performance levels of structural members were evaluated for all structures. According to the results of the structural analysis, significantly larger lateral displacement and slightly higher lateral strength with respect to original performance are possible by jacketing the columns of the building with CFRP sheets. On the other hand, a moderate larger lateral displacement and higher lateral strength by using steel-jackets was seen. In the case of reinforced concrete jacketing, the lateral strength and stiffness were significantly increased, as well as a remarkable improvement of the lateral displacement capacity.
first_indexed 2024-12-23T19:49:18Z
format Article
id doaj.art-79df7ff8f32f40cf9eedce329d87542a
institution Directory Open Access Journal
issn 1687-4048
language English
last_indexed 2024-12-23T19:49:18Z
publishDate 2014-04-01
publisher Taylor & Francis Group
record_format Article
series HBRC Journal
spelling doaj.art-79df7ff8f32f40cf9eedce329d87542a2022-12-21T17:33:26ZengTaylor & Francis GroupHBRC Journal1687-40482014-04-0110110010710.1016/j.hbrcj.2013.07.002NonA. IsmailIn seismic areas many buildings need to be retrofitted. In some cases, it is possible to apply carbon fiber-reinforcement polymer/plastic (CFRP), steel-jackets, and concrete jackets as rehabilitation methods. Several researches have been developed with this technology in the last years. In addition, there are guides for the design of retrofitted systems of existing structures. However, it is necessary to count with reliable methodologies for structural analysis of these structures retrofitted. In some cases, the codes require non-linear analysis for the verification of design proposed as retrofit. In this study, an attempt has been done for investigating the seismic behavior of a typical existing building in Cairo by performing static pushover analysis before and after retrofitting the columns by either, reinforced concrete, steel sections or carbon fiber reinforced polymer (CFRP) composite jackets. The selected model building represents nearly all typical construction deficiencies of buildings constructed before recent earthquake resistant design codes. To investigate the possibility and effectiveness of the use of these systems, a comparative study was performed. A comparison was made between a typical framed RC building and the same building after retrofitting with CFRP confinement, steel elements and concrete jackets. By using nonlinear static (pushover) analysis, the performance levels of structural members were evaluated for all structures. According to the results of the structural analysis, significantly larger lateral displacement and slightly higher lateral strength with respect to original performance are possible by jacketing the columns of the building with CFRP sheets. On the other hand, a moderate larger lateral displacement and higher lateral strength by using steel-jackets was seen. In the case of reinforced concrete jacketing, the lateral strength and stiffness were significantly increased, as well as a remarkable improvement of the lateral displacement capacity.http://www.sciencedirect.com/science/article/pii/S168740481300045XFiber-reinforcement polymer/plasticSteel-jacketsConcrete-jacketsPushover analysis
spellingShingle A. Ismail
Non
HBRC Journal
Fiber-reinforcement polymer/plastic
Steel-jackets
Concrete-jackets
Pushover analysis
title Non
title_full Non
title_fullStr Non
title_full_unstemmed Non
title_short Non
title_sort non
topic Fiber-reinforcement polymer/plastic
Steel-jackets
Concrete-jackets
Pushover analysis
url http://www.sciencedirect.com/science/article/pii/S168740481300045X
work_keys_str_mv AT aismail non