Mass transfer effects on mucus fluid in the presence of chemical reaction

The mucus fluid vehicle is impacted by the synthetic response that changes the physical science of liquid due to the thickness of the bodily fluid. Additionally, various issues in the respiratory system might happen because of bodily fluid adequacy. A central point of transportation of immunizations...

Full description

Bibliographic Details
Main Authors: Padmavathi Thiyagarajan, Sethamilselvi Sathiamoorthy, Hemalatha Balasundaram, Oluwole Daniel Makinde, U. Fernandez-Gamiz, Samad Noeiaghdam, Shyam Sundar Santra, Mohamed Altanji
Format: Article
Language:English
Published: Elsevier 2023-01-01
Series:Alexandria Engineering Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1110016822004100
_version_ 1797943095668506624
author Padmavathi Thiyagarajan
Sethamilselvi Sathiamoorthy
Hemalatha Balasundaram
Oluwole Daniel Makinde
U. Fernandez-Gamiz
Samad Noeiaghdam
Shyam Sundar Santra
Mohamed Altanji
author_facet Padmavathi Thiyagarajan
Sethamilselvi Sathiamoorthy
Hemalatha Balasundaram
Oluwole Daniel Makinde
U. Fernandez-Gamiz
Samad Noeiaghdam
Shyam Sundar Santra
Mohamed Altanji
author_sort Padmavathi Thiyagarajan
collection DOAJ
description The mucus fluid vehicle is impacted by the synthetic response that changes the physical science of liquid due to the thickness of the bodily fluid. Additionally, various issues in the respiratory system might happen because of bodily fluid adequacy. A central point of transportation of immunizations to forestall COVID-19 is the concentration level expected during movement, stockpiling, and dispersion. The current review stated that mucus fluid transportation is restrained through magnetic force originating due to heat variation. Permeable channel over respiratory disease and chemicals due to mass reaction–diffusion variation. The bodily fluid development is surveyed by the force, energy, and diffusion condition influence of body powers because of attractive field, source of heat cause of thermal conduction, resistance due to disease chemical reaction cause of concentration profile. The nonlinear arrangement of incomplete differential conditions is addressed by the Laplace transform technique, and MATLAB programming outcomes are initiated for momentum, temperature, and diffusion fields and inferred that the bodily fluid stream decelerates due to magnetic force. The skin friction, Nusselt number, Sherwood number, and the microorganism’s thickness are assessed and explained exhaustively. Furthermore, microorganisms are occupied in different elements to survey the mucus fluid mechanism.
first_indexed 2024-04-10T20:18:59Z
format Article
id doaj.art-79f32cbaad2d430981a87f4781aaec83
institution Directory Open Access Journal
issn 1110-0168
language English
last_indexed 2024-04-10T20:18:59Z
publishDate 2023-01-01
publisher Elsevier
record_format Article
series Alexandria Engineering Journal
spelling doaj.art-79f32cbaad2d430981a87f4781aaec832023-01-26T04:44:05ZengElsevierAlexandria Engineering Journal1110-01682023-01-0162193210Mass transfer effects on mucus fluid in the presence of chemical reactionPadmavathi Thiyagarajan0Sethamilselvi Sathiamoorthy1Hemalatha Balasundaram2Oluwole Daniel Makinde3U. Fernandez-Gamiz4Samad Noeiaghdam5Shyam Sundar Santra6Mohamed Altanji7Department of Mathematics, VISTAS, Vels University, Pallavaram 600117, IndiaDepartment of Mathematics, VISTAS, Vels University, Pallavaram 600117, IndiaDepartment of Mathematics, VISTAS, Vels University, Pallavaram 600117, IndiaFaculty of Military Science, Stellenbosch University, Private Bag X1, Matieland 7602 South AfricaNuclear Engineering and Fluid Mechanics Department, University of the Basque Country UPV/EHU, Nieves Cano 12, 01006 Vitoria-Gasteiz, Spain; Corresponding author.Industrial Mathematics Laboratory, Baikal School of BRICS, Irkutsk National Research Technical University, Irkutsk 664074, Russia; Department of Applied Mathematics and Programming, South Ural State University, Lenin prospect 76, Chelyabinsk 454080, RussiaDepartment of Mathematics, JIS College of Engineering, Kalyani, West Bengal 741235, IndiaDepartment of Mathematics, College of Science, King Khalid University, Abha 61413, Saudi ArabiaThe mucus fluid vehicle is impacted by the synthetic response that changes the physical science of liquid due to the thickness of the bodily fluid. Additionally, various issues in the respiratory system might happen because of bodily fluid adequacy. A central point of transportation of immunizations to forestall COVID-19 is the concentration level expected during movement, stockpiling, and dispersion. The current review stated that mucus fluid transportation is restrained through magnetic force originating due to heat variation. Permeable channel over respiratory disease and chemicals due to mass reaction–diffusion variation. The bodily fluid development is surveyed by the force, energy, and diffusion condition influence of body powers because of attractive field, source of heat cause of thermal conduction, resistance due to disease chemical reaction cause of concentration profile. The nonlinear arrangement of incomplete differential conditions is addressed by the Laplace transform technique, and MATLAB programming outcomes are initiated for momentum, temperature, and diffusion fields and inferred that the bodily fluid stream decelerates due to magnetic force. The skin friction, Nusselt number, Sherwood number, and the microorganism’s thickness are assessed and explained exhaustively. Furthermore, microorganisms are occupied in different elements to survey the mucus fluid mechanism.http://www.sciencedirect.com/science/article/pii/S1110016822004100Chemical reactionCoronavirusesMagnetic forceMass transferMucus fluidPorosity parameter
spellingShingle Padmavathi Thiyagarajan
Sethamilselvi Sathiamoorthy
Hemalatha Balasundaram
Oluwole Daniel Makinde
U. Fernandez-Gamiz
Samad Noeiaghdam
Shyam Sundar Santra
Mohamed Altanji
Mass transfer effects on mucus fluid in the presence of chemical reaction
Alexandria Engineering Journal
Chemical reaction
Coronaviruses
Magnetic force
Mass transfer
Mucus fluid
Porosity parameter
title Mass transfer effects on mucus fluid in the presence of chemical reaction
title_full Mass transfer effects on mucus fluid in the presence of chemical reaction
title_fullStr Mass transfer effects on mucus fluid in the presence of chemical reaction
title_full_unstemmed Mass transfer effects on mucus fluid in the presence of chemical reaction
title_short Mass transfer effects on mucus fluid in the presence of chemical reaction
title_sort mass transfer effects on mucus fluid in the presence of chemical reaction
topic Chemical reaction
Coronaviruses
Magnetic force
Mass transfer
Mucus fluid
Porosity parameter
url http://www.sciencedirect.com/science/article/pii/S1110016822004100
work_keys_str_mv AT padmavathithiyagarajan masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT sethamilselvisathiamoorthy masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT hemalathabalasundaram masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT oluwoledanielmakinde masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT ufernandezgamiz masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT samadnoeiaghdam masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT shyamsundarsantra masstransfereffectsonmucusfluidinthepresenceofchemicalreaction
AT mohamedaltanji masstransfereffectsonmucusfluidinthepresenceofchemicalreaction