Code provisions evaluation for the punching shear capacity of R.C footings without reinforcement for punching shear
There is no agreement on how to predict punching shear for footings among different design codes, which is inconsistent with experimentally observed capacity. Such inconsistency is due to the following issues: (1) the different definitions used by design codes for the critical section that resists t...
Auteurs principaux: | Amr El-said, Ahmed F. Deifalla, Saif Eldeen A.S. Yousef, Taha A. El-Sayed, Maged Tawfik, Nehal M. Ayash |
---|---|
Format: | Article |
Langue: | English |
Publié: |
Elsevier
2023-07-01
|
Collection: | Case Studies in Construction Materials |
Sujets: | |
Accès en ligne: | http://www.sciencedirect.com/science/article/pii/S2214509523003625 |
Documents similaires
-
Effect of Shape, Number, and Location of Openings on Punching Shear Capacity of Flat Slabs
par: Ekkachai Yooprasertchai, et autres
Publié: (2021-10-01) -
Investigation of punching shear behavior of flat slabs with different types and arrangements of shear reinforcement
par: Nasim Shatarat, et autres
Publié: (2022-06-01) -
Comparison of seismic fragility of special moment frames in recent editions of ASCE 7 and ACI 318 regulations
par: Farhad Behnamfar, et autres
Publié: (2022-05-01) -
Behavior of RC Slabs subjected to Eccentric Punching Shear
par: Abanoub atallah, et autres
Publié: (2020-03-01) -
Punching shear strength and deformation for FRP-reinforced concrete slabs without shear reinforcements
par: A. Deifalla
Publié: (2022-06-01)