Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor

Localizing safety systems are provided to contain radioactive substances in an accident and attenuate ionizing radiation at a modern nuclear power plant. Together with radioactive substances, hydrogen is also retained, which is formed during the decomposition of the primary coolant. The accumulation...

Full description

Bibliographic Details
Main Author: V. V. Sorokin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2021-04-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/2060
_version_ 1797879740839755776
author V. V. Sorokin
author_facet V. V. Sorokin
author_sort V. V. Sorokin
collection DOAJ
description Localizing safety systems are provided to contain radioactive substances in an accident and attenuate ionizing radiation at a modern nuclear power plant. Together with radioactive substances, hydrogen is also retained, which is formed during the decomposition of the primary coolant. The accumulation of hydrogen in the presence of oxygen from the atmosphere in the accident localization zone carries the danger of the formation of flammable and explosive concentrations of these components. Nuclear power plant (NPP) deigns with water-water energetic reactor (WWER) provides for a hydrogen removal system including passive catalytic hydrogen recombiners. The device capacity  is confirmed experimentally under reference conditions (lean air-hydrogen mixture, pressure and temperature close to normal, no interference with gas exchange). Capacity is an important safety parameter. In the event of an accident, conditions inside the ealed enclosure of the localizing system of NPP with WWER can  differ from the reference  ones and affect the capacity.  On the basis of calculations, the operation of recombiners with lack of  oxygen  and with hindered  gas exchange has been investigated in the paper. The decrease in capacity with lack of oxygen reaches 50 %, which is mainly  caused by an increase in underburning. Compared to the reference conditions, the effect is more pronounced in the event of an accident – 60–70 %. The hindered gas exchange is modeled by a decrease in the height of recombiner traction channel. This case can be reduced to the placement of the device in cramped conditions and the effect of the atmosphere speed inside the enclosure. Regardless of the hydrogen concentration, the operating characteristic of the device remains linear, with a two-fold decrease in height leads to a decrease in capacity by 20 %. The results can be used to substantiate the safety of NPPs with WWER and to review on the safety subtantiation of power units.
first_indexed 2024-04-10T02:52:10Z
format Article
id doaj.art-7acc1f5a719a4e92a419fce3891af9dc
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:52:10Z
publishDate 2021-04-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-7acc1f5a719a4e92a419fce3891af9dc2023-03-13T07:41:52ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412021-04-0164217818610.21122/1029-7448-2021-64-2-178-1861759Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic ReactorV. V. Sorokin0Белорусский национальный технический университетLocalizing safety systems are provided to contain radioactive substances in an accident and attenuate ionizing radiation at a modern nuclear power plant. Together with radioactive substances, hydrogen is also retained, which is formed during the decomposition of the primary coolant. The accumulation of hydrogen in the presence of oxygen from the atmosphere in the accident localization zone carries the danger of the formation of flammable and explosive concentrations of these components. Nuclear power plant (NPP) deigns with water-water energetic reactor (WWER) provides for a hydrogen removal system including passive catalytic hydrogen recombiners. The device capacity  is confirmed experimentally under reference conditions (lean air-hydrogen mixture, pressure and temperature close to normal, no interference with gas exchange). Capacity is an important safety parameter. In the event of an accident, conditions inside the ealed enclosure of the localizing system of NPP with WWER can  differ from the reference  ones and affect the capacity.  On the basis of calculations, the operation of recombiners with lack of  oxygen  and with hindered  gas exchange has been investigated in the paper. The decrease in capacity with lack of oxygen reaches 50 %, which is mainly  caused by an increase in underburning. Compared to the reference conditions, the effect is more pronounced in the event of an accident – 60–70 %. The hindered gas exchange is modeled by a decrease in the height of recombiner traction channel. This case can be reduced to the placement of the device in cramped conditions and the effect of the atmosphere speed inside the enclosure. Regardless of the hydrogen concentration, the operating characteristic of the device remains linear, with a two-fold decrease in height leads to a decrease in capacity by 20 %. The results can be used to substantiate the safety of NPPs with WWER and to review on the safety subtantiation of power units.https://energy.bntu.by/jour/article/view/2060аэсввэрводородная безопасностьпассивные каталитические рекомбинаторы водородагерметичная оболочканедостаток кислородаусловия размещениярасчеты
spellingShingle V. V. Sorokin
Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
аэс
ввэр
водородная безопасность
пассивные каталитические рекомбинаторы водорода
герметичная оболочка
недостаток кислорода
условия размещения
расчеты
title Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
title_full Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
title_fullStr Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
title_full_unstemmed Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
title_short Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
title_sort аnalysis catalytic hydrogen recombiner capacity calculation taking into account conditions inside sealed enclosure of containment safety system of nuclear power plants with water water energetic reactor
topic аэс
ввэр
водородная безопасность
пассивные каталитические рекомбинаторы водорода
герметичная оболочка
недостаток кислорода
условия размещения
расчеты
url https://energy.bntu.by/jour/article/view/2060
work_keys_str_mv AT vvsorokin analysiscatalytichydrogenrecombinercapacitycalculationtakingintoaccountconditionsinsidesealedenclosureofcontainmentsafetysystemofnuclearpowerplantswithwaterwaterenergeticreactor