Measurement and analysis of underground electromagnetic interference of medium and low frequency band
In view of problem that underground monitoring devices are mainly influenced by electromagnetic interferences of medium and low frequency band, main electromagnetic interferences of medium and low frequency band of coal mine underground, namely surge interference of underground power cable, interfer...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2013-05-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/id/9105 |
_version_ | 1827988155096104960 |
---|---|
author | ZOU Zhe-qiang ZHUANG Jie QU Shi-jia |
author_facet | ZOU Zhe-qiang ZHUANG Jie QU Shi-jia |
author_sort | ZOU Zhe-qiang |
collection | DOAJ |
description | In view of problem that underground monitoring devices are mainly influenced by electromagnetic interferences of medium and low frequency band, main electromagnetic interferences of medium and low frequency band of coal mine underground, namely surge interference of underground power cable, interference of power frequency converter, interference of grounded grid, radiated interference of motor and electrical devices, interference of trolley locomotive and interference of leakage communication system, were measured and analyzed with oscilloscope and spectrum analyzer. The analysis results show that the surge interference of power cable, interference of power frequency converter and radiated interference of motor and electrical devices are bigger than the others, the next are the interferences of grounded grid and trolley locomotive, and the one after the next are the interference of leakage communication system and the power interference of power cable. |
first_indexed | 2024-04-09T23:59:06Z |
format | Article |
id | doaj.art-7b01454c27e440a5ad58a00fb2a7afe1 |
institution | Directory Open Access Journal |
issn | 1671-251X |
language | zho |
last_indexed | 2024-04-09T23:59:06Z |
publishDate | 2013-05-01 |
publisher | Editorial Department of Industry and Mine Automation |
record_format | Article |
series | Gong-kuang zidonghua |
spelling | doaj.art-7b01454c27e440a5ad58a00fb2a7afe12023-03-17T01:58:35ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2013-05-0139515Measurement and analysis of underground electromagnetic interference of medium and low frequency bandZOU Zhe-qiangZHUANG JieQU Shi-jiaIn view of problem that underground monitoring devices are mainly influenced by electromagnetic interferences of medium and low frequency band, main electromagnetic interferences of medium and low frequency band of coal mine underground, namely surge interference of underground power cable, interference of power frequency converter, interference of grounded grid, radiated interference of motor and electrical devices, interference of trolley locomotive and interference of leakage communication system, were measured and analyzed with oscilloscope and spectrum analyzer. The analysis results show that the surge interference of power cable, interference of power frequency converter and radiated interference of motor and electrical devices are bigger than the others, the next are the interferences of grounded grid and trolley locomotive, and the one after the next are the interference of leakage communication system and the power interference of power cable.http://www.gkzdh.cn/article/id/9105coal mineelectromagnetic interferencemedium and low frequency bandmeasurement of interferencepower interferencefrequency of interference |
spellingShingle | ZOU Zhe-qiang ZHUANG Jie QU Shi-jia Measurement and analysis of underground electromagnetic interference of medium and low frequency band Gong-kuang zidonghua coal mine electromagnetic interference medium and low frequency band measurement of interference power interference frequency of interference |
title | Measurement and analysis of underground electromagnetic interference of medium and low frequency band |
title_full | Measurement and analysis of underground electromagnetic interference of medium and low frequency band |
title_fullStr | Measurement and analysis of underground electromagnetic interference of medium and low frequency band |
title_full_unstemmed | Measurement and analysis of underground electromagnetic interference of medium and low frequency band |
title_short | Measurement and analysis of underground electromagnetic interference of medium and low frequency band |
title_sort | measurement and analysis of underground electromagnetic interference of medium and low frequency band |
topic | coal mine electromagnetic interference medium and low frequency band measurement of interference power interference frequency of interference |
url | http://www.gkzdh.cn/article/id/9105 |
work_keys_str_mv | AT zouzheqiang measurementandanalysisofundergroundelectromagneticinterferenceofmediumandlowfrequencyband AT zhuangjie measurementandanalysisofundergroundelectromagneticinterferenceofmediumandlowfrequencyband AT qushijia measurementandanalysisofundergroundelectromagneticinterferenceofmediumandlowfrequencyband |