Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer

The membrane structure roof is widely used in large-span buildings such as stadiums and gymnasiums because of its full use of natural light sources and flexible forms. In order to solve the prominent problems such as poor thermal insulation performance and prone to external environmental factors, th...

Full description

Bibliographic Details
Main Author: SONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie
Format: Article
Language:zho
Published: Editorial Office of Journal of Shanghai Jiao Tong University 2023-02-01
Series:Shanghai Jiaotong Daxue xuebao
Subjects:
Online Access:https://xuebao.sjtu.edu.cn/article/2023/1006-2467/1006-2467-57-2-183.shtml
_version_ 1811161433688244224
author SONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie
author_facet SONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie
author_sort SONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie
collection DOAJ
description The membrane structure roof is widely used in large-span buildings such as stadiums and gymnasiums because of its full use of natural light sources and flexible forms. In order to solve the prominent problems such as poor thermal insulation performance and prone to external environmental factors, the multi-layer membrane structure design, laying of insulation layers, and other schemes are applied to engineering practice. However, there is still a gap in the relevant research of thermal environment monitoring and analysis. In order to study the thermal environment of the double-layer PTFE (polytetrafluoroethylene)-aerogel roof, multi-point thermometers were uniformly arranged to monitor, and the overall temperature field was constructed using the measured data. A thermophysical model which could accurately reflect the change of temperature field was established, whose average error was less than 5%. With the laying of roof insulation layer as the variable, three working conditions, i.e., no insulation layer, only rock wool insulation layer, and all aerogel insulation layer were constructed based on the model. The comparison indicates that the laying of aerogel reduces the average temperature of indoor space by 2.0 ℃, the original working condition has the best thermal insulation effect, and the average temperature difference between indoor and outdoor is 9.6 ℃. This paper can provide reference for the thermal insulation design of membrane structure roofs.
first_indexed 2024-04-10T06:15:14Z
format Article
id doaj.art-7b078d763aa8489ea117856e9ec7ec38
institution Directory Open Access Journal
issn 1006-2467
language zho
last_indexed 2024-04-10T06:15:14Z
publishDate 2023-02-01
publisher Editorial Office of Journal of Shanghai Jiao Tong University
record_format Article
series Shanghai Jiaotong Daxue xuebao
spelling doaj.art-7b078d763aa8489ea117856e9ec7ec382023-03-02T09:41:50ZzhoEditorial Office of Journal of Shanghai Jiao Tong UniversityShanghai Jiaotong Daxue xuebao1006-24672023-02-0157218319310.16183/j.cnki.jsjtu.2021.259Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in SummerSONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie01. Space Structures Research Center, Shanghai Jiao Tong University, Shanghai 200240, China;2. Shanghai Haibo Membrane Structure Co., Ltd., Shanghai 200240, ChinaThe membrane structure roof is widely used in large-span buildings such as stadiums and gymnasiums because of its full use of natural light sources and flexible forms. In order to solve the prominent problems such as poor thermal insulation performance and prone to external environmental factors, the multi-layer membrane structure design, laying of insulation layers, and other schemes are applied to engineering practice. However, there is still a gap in the relevant research of thermal environment monitoring and analysis. In order to study the thermal environment of the double-layer PTFE (polytetrafluoroethylene)-aerogel roof, multi-point thermometers were uniformly arranged to monitor, and the overall temperature field was constructed using the measured data. A thermophysical model which could accurately reflect the change of temperature field was established, whose average error was less than 5%. With the laying of roof insulation layer as the variable, three working conditions, i.e., no insulation layer, only rock wool insulation layer, and all aerogel insulation layer were constructed based on the model. The comparison indicates that the laying of aerogel reduces the average temperature of indoor space by 2.0 ℃, the original working condition has the best thermal insulation effect, and the average temperature difference between indoor and outdoor is 9.6 ℃. This paper can provide reference for the thermal insulation design of membrane structure roofs.https://xuebao.sjtu.edu.cn/article/2023/1006-2467/1006-2467-57-2-183.shtmlmembrane structurethermal environmentenclosed gymnasiumaerogel
spellingShingle SONG Yinbo, YIN Yue, YAN Yongsheng, WANG Xiaoqing, CHEN Wujun, REN Sijie
Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
Shanghai Jiaotong Daxue xuebao
membrane structure
thermal environment
enclosed gymnasium
aerogel
title Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
title_full Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
title_fullStr Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
title_full_unstemmed Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
title_short Thermal Environment Monitoring and Analysis of an Enclosed Gymnasium with Double-Layered Membrane Roof in Summer
title_sort thermal environment monitoring and analysis of an enclosed gymnasium with double layered membrane roof in summer
topic membrane structure
thermal environment
enclosed gymnasium
aerogel
url https://xuebao.sjtu.edu.cn/article/2023/1006-2467/1006-2467-57-2-183.shtml
work_keys_str_mv AT songyinboyinyueyanyongshengwangxiaoqingchenwujunrensijie thermalenvironmentmonitoringandanalysisofanenclosedgymnasiumwithdoublelayeredmembraneroofinsummer